{
  "source_id": "d076a35d06cd97d79020a67c3e5c72167b529db8b3899f8c8a51450e77e3893d",
  "pages": [
    {
      "index": 0,
      "width": 595.3200073242188,
      "height": 842.0399780273438,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS TRANSFORMERS. \nREFERENCE NO: REF/Inter/02/03/2022 \n \n \nPage 1 of 52 \n \nRURAL ELECTRIFICATION FUND  \n \n \n \nBIDDING DOCUMENT \nfor the  \nSupply and delivery of various transformers  \n \n \n               Tender Closing Date: 08 April 2022 , Time:1000hrs \n  \n              Tender Number: REF/Inter/02/03/2022 \n \n            Date of tender advert: 11 March 2022 \n \n \n \n \n",
      "image_ratio": 0.025858579800613627,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            79.46399688720703,
            39.450321197509766,
            516.9400024414062,
            68.47200775146484
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS TRANSFORMERS. \nREFERENCE NO: REF/Inter/02/03/2022 \n"
        },
        {
          "bbox": [
            79.46399688720703,
            774.485595703125,
            81.95399475097656,
            785.5113525390625
          ],
          "text": " \n"
        },
        {
          "bbox": [
            79.46399688720703,
            792.005615234375,
            323.67999267578125,
            803.0313720703125
          ],
          "text": " \nPage 1 of 52 \n"
        },
        {
          "bbox": [
            105.5,
            74.76795959472656,
            509.6199951171875,
            115.7239761352539
          ],
          "text": " \nRURAL ELECTRIFICATION FUND  \n"
        },
        {
          "bbox": [
            301.489990234375,
            116.46199798583984,
            305.989990234375,
            136.38800048828125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            79.46399688720703,
            246.76995849609375,
            358.5820007324219,
            268.9099426269531
          ],
          "text": " \n \n"
        },
        {
          "bbox": [
            143.05999755859375,
            277.2139892578125,
            468.82000732421875,
            317.06597900390625
          ],
          "text": "BIDDING DOCUMENT \n"
        },
        {
          "bbox": [
            131.05999755859375,
            323.85198974609375,
            480.760009765625,
            364.41796875
          ],
          "text": "for the  \nSupply and delivery of various transformers  \n"
        },
        {
          "bbox": [
            79.46399688720703,
            365.2519836425781,
            305.989990234375,
            398.6619873046875
          ],
          "text": " \n \n"
        },
        {
          "bbox": [
            79.46399688720703,
            405.7296142578125,
            486.25,
            423.3973388671875
          ],
          "text": "               Tender Closing Date: 08 April 2022 , Time:1000hrs \n"
        },
        {
          "bbox": [
            79.46399688720703,
            436.089599609375,
            87.41400146484375,
            453.75732421875
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            79.46399688720703,
            466.5696105957031,
            407.97998046875,
            484.2373352050781
          ],
          "text": "              Tender Number: REF/Inter/02/03/2022 \n"
        },
        {
          "bbox": [
            79.46399688720703,
            496.37799072265625,
            427.92999267578125,
            536.6380004882812
          ],
          "text": " \n            Date of tender advert: 11 March 2022 \n"
        },
        {
          "bbox": [
            79.46399688720703,
            542.8479614257812,
            82.46399688720703,
            556.1319580078125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            79.46399688720703,
            568.64794921875,
            82.46399688720703,
            581.9319458007812
          ],
          "text": " \n"
        },
        {
          "bbox": [
            79.46399688720703,
            588.68798828125,
            304.489990234375,
            615.77197265625
          ],
          "text": " \n \n"
        }
      ]
    },
    {
      "index": 1,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS TRANSFORMERS. \nREFERENCE NO: REF/Inter/02/03/2022 \n \n \nPage 2 of 52 \n \nRURAL ELECTRIFICATION FUND \n \n \n \nDECLARATION BY THE ACCOUNTING OFFICER IN TERMS OF SECTION 19(2)(C) OF THE \nPUBLIC PROCUREMENT AND DISPOSAL OF PUBLIC ASSETS REGULATIONS,2018. \n \nTENDER NUMBER: REF/INTER/02/03/2022 \n    \nTENDER DESCRIPTION-SUPPLY AND DELIVERY OF CONDUCTOR CABLES     \n \nDECLARATION \n \nThe procurement for the tendered goods/items is based on neutral and fair \ntechnical requirements and bidder qualifications. \n \n \nSigned \n \n \n \n............................. \nJ.V MASHAMBA \nCHIEF EXECUTIVE OFFICER \n \n \n \n \n \n \n \n \n \nTable of Contents \n",
      "image_ratio": 0.01386140556181075,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            509.5,
            60.79201126098633
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS TRANSFORMERS. \nREFERENCE NO: REF/Inter/02/03/2022 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            316.239990234375,
            810.3273315429688
          ],
          "text": " \nPage 2 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            78.10798645019531,
            75.02400207519531,
            91.3919906616211
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            95.75601196289062,
            500.3800048828125,
            136.05201721191406
          ],
          "text": "RURAL ELECTRIFICATION FUND \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            208.32801818847656,
            527.820068359375,
            259.9999694824219
          ],
          "text": " \n \nDECLARATION BY THE ACCOUNTING OFFICER IN TERMS OF SECTION 19(2)(C) OF THE \nPUBLIC PROCUREMENT AND DISPOSAL OF PUBLIC ASSETS REGULATIONS,2018. \n"
        },
        {
          "bbox": [
            162.02000427246094,
            259.3955078125,
            170.4359588623047,
            291.38177490234375
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            293.2264099121094,
            527.580078125,
            406.30999755859375
          ],
          "text": "TENDER NUMBER: REF/INTER/02/03/2022 \n    \nTENDER DESCRIPTION-SUPPLY AND DELIVERY OF CONDUCTOR CABLES     \n \nDECLARATION \n \nThe procurement for the tendered goods/items is based on neutral and fair \ntechnical requirements and bidder qualifications. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            406.6219787597656,
            165.6320037841797,
            448.1899719238281
          ],
          "text": " \n \nSigned \n"
        },
        {
          "bbox": [
            72.02400207519531,
            448.4019775390625,
            224.1020050048828,
            531.7300415039062
          ],
          "text": " \n \n \n............................. \nJ.V MASHAMBA \nCHIEF EXECUTIVE OFFICER \n"
        },
        {
          "bbox": [
            298.25,
            538.9779663085938,
            301.25,
            552.261962890625
          ],
          "text": " \n"
        },
        {
          "bbox": [
            298.25,
            561.7779541015625,
            301.25,
            575.0619506835938
          ],
          "text": " \n"
        },
        {
          "bbox": [
            298.25,
            584.5780029296875,
            301.25,
            597.8619995117188
          ],
          "text": " \n"
        },
        {
          "bbox": [
            298.25,
            607.3779907226562,
            301.25,
            620.6619873046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            298.25,
            630.177978515625,
            301.25,
            643.4619750976562
          ],
          "text": " \n"
        },
        {
          "bbox": [
            298.25,
            653.0079956054688,
            301.25,
            666.2919921875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            298.25,
            675.8079833984375,
            301.25,
            689.0919799804688
          ],
          "text": " \n"
        },
        {
          "bbox": [
            298.25,
            698.6079711914062,
            301.25,
            711.8919677734375
          ],
          "text": " \n"
        },
        {
          "bbox": [
            298.25,
            721.407958984375,
            301.25,
            734.6919555664062
          ],
          "text": " \n"
        },
        {
          "bbox": [
            252.64999389648438,
            744.083984375,
            346.989990234375,
            757.3679809570312
          ],
          "text": "Table of Contents \n"
        }
      ]
    },
    {
      "index": 2,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS TRANSFORMERS. \nREFERENCE NO: REF/Inter/02/03/2022 \n \n \nPage 3 of 52 \n \n \nPart 1: Bidding Procedures \nPart 2: Statement of Requirements \nPart 3: Contract \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            509.5,
            60.79201126098633
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS TRANSFORMERS. \nREFERENCE NO: REF/Inter/02/03/2022 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            316.239990234375,
            810.3273315429688
          ],
          "text": " \nPage 3 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            72.10798645019531,
            75.02400207519531,
            99.21199798583984
          ],
          "text": " \n \n"
        },
        {
          "bbox": [
            142.94000244140625,
            111.96797180175781,
            286.25,
            125.2519760131836
          ],
          "text": "Part 1: Bidding Procedures \n"
        },
        {
          "bbox": [
            142.94000244140625,
            149.7680206298828,
            324.54998779296875,
            163.05201721191406
          ],
          "text": "Part 2: Statement of Requirements \n"
        },
        {
          "bbox": [
            142.94000244140625,
            187.56800842285156,
            230.57000732421875,
            200.8520050048828
          ],
          "text": "Part 3: Contract \n"
        },
        {
          "bbox": [
            72.02400207519531,
            219.1280059814453,
            75.02400207519531,
            232.41200256347656
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            241.92799377441406,
            75.02400207519531,
            255.2119903564453
          ],
          "text": " \n"
        }
      ]
    },
    {
      "index": 3,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 4 of 52 \nPART 1: BIDDING PROCEDURES \nReferences: \nReferences to the Act are to the Public Procurement and Disposal of Public Assets Act \n[Chapter22:23] and references to the Regulations are to the Public Procurement and Disposal \nof Public Assets (General) Regulations (Statutory Instrument No. 5 of 2018).  The terms and \nrequirements in the Act and Regulations govern the submission of Bids and should be read by \nall Bidders. The evaluation of this tender shall be guided by requirements of the Act. \nTable of tender requirements \n \n \n11KV \n19.1 Kv \n33KV \nSIZE \n10kVA \n25Kv\na \n50kVA \n100kVA \n16 \nKva \n32 \nkVA \n64 \nkVA \n475 \nkVA \nAuto \n15kV\nA \n25 \nkVA \n50k\nVA \n100k\nVA \nTENDER \nQTY \n10 \n65 \n55 \n8 \n8 \n11 \n1 \n2 \n2 \n4 \n3 \n23 \n8 \nLOT No \n1 \n2 \n3 \n4 \n5 \n6 \n7 \n8 \n9 \n10 \n11 \n12 \n13 \n \nPreparation of Bids \nYou are requested to bid for the supply of the goods specified in the Statement of \nRequirements below, by completing and returning the following documentation: \n1. the Bid Submission Sheet in this Part; \n2. the Statement of Requirements in Part 2; \n3. a copy of every document necessary to demonstrate eligibility in terms of section 28 (1) \nof the Regulations; \n4. Supplier Registration number showing that you are registered with the Procurement \nRegulatory Authority of Zimbabwe(PRAZ); \n5. A bid security or bid securing declaration in the format specified in this Part; \n6. A copy of: \n Company profile \n Certificate of incorporation/proof of company registration in the country of origin  \n Tax clearance certificate/proof of tax compliance  \n CR 14(Proof of company ownership) \n ISO certificate for the manufacturer \n Letter of agency from the manufacturer(for non-manufacturers) \n Two Reference letters  \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            316.239990234375,
            810.3273315429688
          ],
          "text": " \nPage 4 of 52 \n"
        },
        {
          "bbox": [
            220.3699951171875,
            89.88801574707031,
            378.19000244140625,
            103.1720199584961
          ],
          "text": "PART 1: BIDDING PROCEDURES \n"
        },
        {
          "bbox": [
            72.02400207519531,
            112.68800354003906,
            135.02000427246094,
            125.97200775146484
          ],
          "text": "References: \n"
        },
        {
          "bbox": [
            72.02400207519531,
            135.2480010986328,
            526.5159912109375,
            203.7320098876953
          ],
          "text": "References to the Act are to the Public Procurement and Disposal of Public Assets Act \n[Chapter22:23] and references to the Regulations are to the Public Procurement and Disposal \nof Public Assets (General) Regulations (Statutory Instrument No. 5 of 2018).  The terms and \nrequirements in the Act and Regulations govern the submission of Bids and should be read by \nall Bidders. The evaluation of this tender shall be guided by requirements of the Act. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            213.4879913330078,
            225.41000366210938,
            226.77198791503906
          ],
          "text": "Table of tender requirements \n"
        },
        {
          "bbox": [
            72.02400207519531,
            236.28797912597656,
            75.02400207519531,
            249.5719757080078
          ],
          "text": " \n"
        },
        {
          "bbox": [
            20.639999389648438,
            256.5680236816406,
            464.8599853515625,
            269.8520202636719
          ],
          "text": " \n11KV \n19.1 Kv \n33KV \n"
        },
        {
          "bbox": [
            20.639999389648438,
            281.0956115722656,
            142.87998962402344,
            303.641357421875
          ],
          "text": "SIZE \n10kVA \n25Kv\na \n"
        },
        {
          "bbox": [
            155.4199981689453,
            281.0956115722656,
            274.94000244140625,
            303.641357421875
          ],
          "text": "50kVA \n100kVA \n16 \nKva \n"
        },
        {
          "bbox": [
            290.0899963378906,
            281.0956115722656,
            312.6399841308594,
            303.641357421875
          ],
          "text": "32 \nkVA \n"
        },
        {
          "bbox": [
            325.6300048828125,
            281.0956115722656,
            348.1600036621094,
            303.641357421875
          ],
          "text": "64 \nkVA \n"
        },
        {
          "bbox": [
            360.9100036621094,
            281.0956115722656,
            383.44000244140625,
            303.641357421875
          ],
          "text": "475 \nkVA \n"
        },
        {
          "bbox": [
            396.42999267578125,
            281.0956115722656,
            454.5090637207031,
            303.641357421875
          ],
          "text": "Auto \n15kV\nA \n"
        },
        {
          "bbox": [
            467.3800048828125,
            281.0956115722656,
            489.9100036621094,
            303.641357421875
          ],
          "text": "25 \nkVA \n"
        },
        {
          "bbox": [
            502.7799987792969,
            281.0956115722656,
            519.6699829101562,
            303.641357421875
          ],
          "text": "50k\nVA \n"
        },
        {
          "bbox": [
            531.0999755859375,
            281.0956115722656,
            551.7576904296875,
            303.641357421875
          ],
          "text": "100k\nVA \n"
        },
        {
          "bbox": [
            20.639999389648438,
            310.6156311035156,
            64.64328002929688,
            333.1613464355469
          ],
          "text": "TENDER \nQTY \n"
        },
        {
          "bbox": [
            77.42400360107422,
            310.6156311035156,
            538.6300048828125,
            321.641357421875
          ],
          "text": "10 \n65 \n55 \n8 \n8 \n11 \n1 \n2 \n2 \n4 \n3 \n23 \n8 \n"
        },
        {
          "bbox": [
            20.639999389648438,
            340.1180114746094,
            546.1199951171875,
            353.4020080566406
          ],
          "text": "LOT No \n1 \n2 \n3 \n4 \n5 \n6 \n7 \n8 \n9 \n10 \n11 \n12 \n13 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            363.9980163574219,
            75.02400207519531,
            377.2820129394531
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            383.7980041503906,
            175.6999969482422,
            397.0820007324219
          ],
          "text": "Preparation of Bids \n"
        },
        {
          "bbox": [
            72.02400207519531,
            403.3580017089844,
            465.2180480957031,
            430.4420166015625
          ],
          "text": "You are requested to bid for the supply of the goods specified in the Statement of \nRequirements below, by completing and returning the following documentation: \n"
        },
        {
          "bbox": [
            72.02400207519531,
            436.7900085449219,
            275.0899963378906,
            450.24200439453125
          ],
          "text": "1. the Bid Submission Sheet in this Part; \n"
        },
        {
          "bbox": [
            72.02400207519531,
            456.6100158691406,
            288.4100036621094,
            470.06201171875
          ],
          "text": "2. the Statement of Requirements in Part 2; \n"
        },
        {
          "bbox": [
            72.02400207519531,
            476.4100036621094,
            514.7179565429688,
            503.6620178222656
          ],
          "text": "3. a copy of every document necessary to demonstrate eligibility in terms of section 28 (1) \nof the Regulations; \n"
        },
        {
          "bbox": [
            72.02400207519531,
            510.010009765625,
            494.87799072265625,
            537.261962890625
          ],
          "text": "4. Supplier Registration number showing that you are registered with the Procurement \nRegulatory Authority of Zimbabwe(PRAZ); \n"
        },
        {
          "bbox": [
            72.02400207519531,
            543.6099853515625,
            462.1000061035156,
            557.0619506835938
          ],
          "text": "5. A bid security or bid securing declaration in the format specified in this Part; \n"
        },
        {
          "bbox": [
            72.02400207519531,
            563.4100341796875,
            144.3800048828125,
            576.8619995117188
          ],
          "text": "6. A copy of: \n"
        },
        {
          "bbox": [
            107.9000015258789,
            582.9700317382812,
            198.64999389648438,
            597.6220092773438
          ],
          "text": " Company profile \n"
        },
        {
          "bbox": [
            107.9000015258789,
            603.6099853515625,
            515.97998046875,
            618.261962890625
          ],
          "text": " Certificate of incorporation/proof of company registration in the country of origin  \n"
        },
        {
          "bbox": [
            107.9000015258789,
            624.25,
            358.2699890136719,
            638.9019775390625
          ],
          "text": " Tax clearance certificate/proof of tax compliance  \n"
        },
        {
          "bbox": [
            107.9000015258789,
            644.9199829101562,
            295.010009765625,
            659.5719604492188
          ],
          "text": " CR 14(Proof of company ownership) \n"
        },
        {
          "bbox": [
            107.9000015258789,
            665.6799926757812,
            290.92999267578125,
            680.3319702148438
          ],
          "text": " ISO certificate for the manufacturer \n"
        },
        {
          "bbox": [
            107.9000015258789,
            686.3200073242188,
            424.29998779296875,
            700.9719848632812
          ],
          "text": " Letter of agency from the manufacturer(for non-manufacturers) \n"
        },
        {
          "bbox": [
            107.9000015258789,
            706.9600219726562,
            225.2899932861328,
            721.6119995117188
          ],
          "text": " Two Reference letters  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            728.2479858398438,
            75.02400207519531,
            741.531982421875
          ],
          "text": " \n"
        }
      ]
    },
    {
      "index": 4,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 5 of 52 \nThe tender is subject to review in terms of Section 54 of the Act,therefore bidders shall be \nrequired to pay the following fees in terms of Part IV of S.I 219 of 2020: \n Equivalent of ZW$30,000.00 for local bidders and USD$400.00 for foreign bidders . \nBidders must attach proof of compliance on the bid documents without fail. \nYou are advised to carefully read the complete Bidding Document, as well as the General \nConditions of Contract which are available on the Authority’s website, before preparing your \nBid.  Part 3: Contract is provided not for completion at this stage but to enable Bidders to \nnote the Contract terms they will enter into if their Bid is successful. \nThe standard forms in this document may be retyped for completion but the Bidder is \nresponsible for their accurate reproduction.  All pages of the Bid should  be clearly marked \nwith the Procurement Reference Number above and the Bidder’s name and any reference \nnumber.  \n \nLots and Packages \nThe tender is divided into lots. Bidders may bid for one or all the Lots  \n \nNumber of bids allowed \nNo Bidder may submit more than one bid, either individually or as a joint venture partner in \nanother Bid, except as a subcontractor. Where the procurement is divided into lots and \npackages, only one Bid can be submitted. A conflict of interest will be deemed to arise if bids \nare received from more than one Bidder owned, directly or indirectly, by the same person. \nClarification \nAll queries regarding the tender shall be forwarded by the bidder in writing on duly signed \ncompany letterhead and emailed on the following three(3) email addresses : \nkchinembiri@rea.co.zw; tshumba@rea.co.zw and buyer1@rea.co.zw , not less than five(5) \nworking days  from the closing date of the tender. Ensure the quiry is emailed to ALL the three \nemail addresses without fail. Clarifications/Responses pertaining to the queries received shall \nuploaded on REF website address www.rea.co.zw on the notice board page. It shall be the \nresponsibility of bidders to continuously check the website for such clarifications/quiry responses. \nIf a prospective tenderer sends a query less than the stated days above, the query may not be \nresponded. Any neglect, delay or failure on the part of the Tenderer to obtain additional \ninformation on the above or any other matters, which the tenderer considers necessary, shall not \nrelieve him/her from responsibility as a Tenderer. Only bidders facing challenges in receiving \nresponses to their quiries may call the Procurement Administrator on 0719 409 691. \n \nPre-bid meeting \nNo pre-bid meeting shall be held in this tender. \n \nValidity of Bids \nThe minimum period for which the Bidder’s bid must remain valid is ninety (90) days from \nthe deadline for the submission of bids.  \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            316.239990234375,
            810.3273315429688
          ],
          "text": " \nPage 5 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            507.23199462890625,
            113.73201751708984
          ],
          "text": "The tender is subject to review in terms of Section 54 of the Act,therefore bidders shall be \nrequired to pay the following fees in terms of Part IV of S.I 219 of 2020: \n"
        },
        {
          "bbox": [
            90.02400207519531,
            119.8399658203125,
            518.5899658203125,
            134.49195861816406
          ],
          "text": " Equivalent of ZW$30,000.00 for local bidders and USD$400.00 for foreign bidders . \n"
        },
        {
          "bbox": [
            108.0199966430664,
            134.8880157470703,
            474.4599914550781,
            148.17201232910156
          ],
          "text": "Bidders must attach proof of compliance on the bid documents without fail. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            154.68800354003906,
            522.2640380859375,
            209.37196350097656
          ],
          "text": "You are advised to carefully read the complete Bidding Document, as well as the General \nConditions of Contract which are available on the Authority’s website, before preparing your \nBid.  Part 3: Contract is provided not for completion at this stage but to enable Bidders to \nnote the Contract terms they will enter into if their Bid is successful. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            215.8880157470703,
            511.5160217285156,
            270.5719909667969
          ],
          "text": "The standard forms in this document may be retyped for completion but the Bidder is \nresponsible for their accurate reproduction.  All pages of the Bid should  be clearly marked \nwith the Procurement Reference Number above and the Bidder’s name and any reference \nnumber.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            277.1180114746094,
            75.02400207519531,
            290.4020080566406
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            297.1579895019531,
            170.4199981689453,
            310.4419860839844
          ],
          "text": "Lots and Packages \n"
        },
        {
          "bbox": [
            72.02400207519531,
            316.9579772949219,
            435.1000061035156,
            330.2419738769531
          ],
          "text": "The tender is divided into lots. Bidders may bid for one or all the Lots  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            336.75799560546875,
            75.02400207519531,
            350.0419921875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            356.5580139160156,
            197.4499969482422,
            369.8420104980469
          ],
          "text": "Number of bids allowed \n"
        },
        {
          "bbox": [
            72.02400207519531,
            376.1180114746094,
            524.6620483398438,
            430.802001953125
          ],
          "text": "No Bidder may submit more than one bid, either individually or as a joint venture partner in \nanother Bid, except as a subcontractor. Where the procurement is divided into lots and \npackages, only one Bid can be submitted. A conflict of interest will be deemed to arise if bids \nare received from more than one Bidder owned, directly or indirectly, by the same person. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            437.5580139160156,
            140.3000030517578,
            450.8420104980469
          ],
          "text": "Clarification \n"
        },
        {
          "bbox": [
            72.02400207519531,
            457.13800048828125,
            526.2999877929688,
            553.2219848632812
          ],
          "text": "All queries regarding the tender shall be forwarded by the bidder in writing on duly signed \ncompany letterhead and emailed on the following three(3) email addresses : \nkchinembiri@rea.co.zw; tshumba@rea.co.zw and buyer1@rea.co.zw , not less than five(5) \nworking days  from the closing date of the tender. Ensure the quiry is emailed to ALL the three \nemail addresses without fail. Clarifications/Responses pertaining to the queries received shall \nuploaded on REF website address www.rea.co.zw on the notice board page. It shall be the \nresponsibility of bidders to continuously check the website for such clarifications/quiry responses. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            559.7379760742188,
            516.2642211914062,
            628.2219848632812
          ],
          "text": "If a prospective tenderer sends a query less than the stated days above, the query may not be \nresponded. Any neglect, delay or failure on the part of the Tenderer to obtain additional \ninformation on the above or any other matters, which the tenderer considers necessary, shall not \nrelieve him/her from responsibility as a Tenderer. Only bidders facing challenges in receiving \nresponses to their quiries may call the Procurement Administrator on 0719 409 691. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            635.0079956054688,
            75.02400207519531,
            648.2919921875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            654.8079833984375,
            157.33999633789062,
            668.0919799804688
          ],
          "text": "Pre-bid meeting \n"
        },
        {
          "bbox": [
            72.02400207519531,
            674.3679809570312,
            301.989990234375,
            687.6519775390625
          ],
          "text": "No pre-bid meeting shall be held in this tender. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            694.16796875,
            75.02400207519531,
            707.4519653320312
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            714.2080078125,
            155.05999755859375,
            727.4920043945312
          ],
          "text": "Validity of Bids \n"
        },
        {
          "bbox": [
            72.02400207519531,
            733.7639770507812,
            514.780029296875,
            760.8479614257812
          ],
          "text": "The minimum period for which the Bidder’s bid must remain valid is ninety (90) days from \nthe deadline for the submission of bids.  \n"
        }
      ]
    },
    {
      "index": 5,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 6 of 52 \n \nSubmission of Bids \nBids must be submitted in writing in a sealed envelope to the address below, no later than the \ndate and time of the deadline below. It is the Bidder’s responsibility to ensure that they \nreceive a receipt confirming submission of their bid that has correct details of the Bidder and \nthe number of the Bid. \nThe Bidder must mark the envelope with the Bidder’s name and address and the \nProcurement Reference Number.  \nBidders must submit three bid documents. The bidder must clearly mark the original copy \n“ORIGINAL.”.Two other copies must be clearly marked “COPY.”  In the event of any \ndiscrepancy between the original and the copies, the original will prevail. \nLate bids will be rejected.  The Procuring Entity reserves the right to extend the bid \nsubmission deadline but will notify all potential bidders who have collected the bidding \ndocuments of the amended bid submission deadline. \n \n \n  \n \n \n \nSubmission address: \nChief Executive Officer  \nRural Electrification Fund  \nMegawatt House \n44 Samora Machel Avenue \nHarare \n \nMeans \nof \nacceptance:  \n  \nTenders must be enclosed in sealed envelopes and endorsed on the \noutside with the advertised tender number , the description and \nclosing date. The bids shall be dropped in the tender box located at \nthe above stated address by the closing date and time personally or \nby post. Upon bid submission, bidders must obtain a bid submission \nreceipt as proof of bid acceptance. Bidders are free to witness the \nopening of the tenders on the named closing date and time. \n \nBid opening \nBidders and their representatives may witness the opening of bids, which will take place at \nthe submission address immediately following the deadline. \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            316.239990234375,
            810.3273315429688
          ],
          "text": " \nPage 6 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.88801574707031,
            75.02400207519531,
            100.1720199584961
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            106.68800354003906,
            172.4600067138672,
            119.97200775146484
          ],
          "text": "Submission of Bids \n"
        },
        {
          "bbox": [
            72.02400207519531,
            126.24800109863281,
            522.76806640625,
            180.9319610595703
          ],
          "text": "Bids must be submitted in writing in a sealed envelope to the address below, no later than the \ndate and time of the deadline below. It is the Bidder’s responsibility to ensure that they \nreceive a receipt confirming submission of their bid that has correct details of the Bidder and \nthe number of the Bid. \n"
        },
        {
          "bbox": [
            75.02400207519531,
            187.44801330566406,
            462.81201171875,
            214.53199768066406
          ],
          "text": "The Bidder must mark the envelope with the Bidder’s name and address and the \nProcurement Reference Number.  \n"
        },
        {
          "bbox": [
            75.02400207519531,
            221.04798889160156,
            509.3800048828125,
            261.9319763183594
          ],
          "text": "Bidders must submit three bid documents. The bidder must clearly mark the original copy \n“ORIGINAL.”.Two other copies must be clearly marked “COPY.”  In the event of any \ndiscrepancy between the original and the copies, the original will prevail. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            268.4779968261719,
            495.55401611328125,
            309.3620300292969
          ],
          "text": "Late bids will be rejected.  The Procuring Entity reserves the right to extend the bid \nsubmission deadline but will notify all potential bidders who have collected the bidding \ndocuments of the amended bid submission deadline. \n"
        },
        {
          "bbox": [
            77.42400360107422,
            312.8780212402344,
            380.95001220703125,
            332.1620178222656
          ],
          "text": " \n \n  \n"
        },
        {
          "bbox": [
            374.95001220703125,
            341.6780090332031,
            377.95001220703125,
            354.9620056152344
          ],
          "text": " \n"
        },
        {
          "bbox": [
            374.95001220703125,
            364.4779968261719,
            377.95001220703125,
            377.7619934082031
          ],
          "text": " \n"
        },
        {
          "bbox": [
            460.05999755859375,
            318.8780212402344,
            463.05999755859375,
            332.1620178222656
          ],
          "text": " \n"
        },
        {
          "bbox": [
            77.42400360107422,
            384.51800537109375,
            317.4700012207031,
            400.56201171875
          ],
          "text": "Submission address: \nChief Executive Officer  \n"
        },
        {
          "bbox": [
            190.85000610351562,
            404.3179931640625,
            333.54998779296875,
            417.60198974609375
          ],
          "text": "Rural Electrification Fund  \n"
        },
        {
          "bbox": [
            190.85000610351562,
            424.1180114746094,
            280.1300048828125,
            437.4020080566406
          ],
          "text": "Megawatt House \n"
        },
        {
          "bbox": [
            190.85000610351562,
            443.9179992675781,
            331.6300048828125,
            457.2019958496094
          ],
          "text": "44 Samora Machel Avenue \n"
        },
        {
          "bbox": [
            190.85000610351562,
            463.7380065917969,
            231.1699981689453,
            477.0220031738281
          ],
          "text": "Harare \n"
        },
        {
          "bbox": [
            190.85000610351562,
            486.2980041503906,
            193.85000610351562,
            499.5820007324219
          ],
          "text": " \n"
        },
        {
          "bbox": [
            77.42400360107422,
            509.0979919433594,
            183.02001953125,
            536.1819458007812
          ],
          "text": "Means \nof \nacceptance:  \n"
        },
        {
          "bbox": [
            190.85000610351562,
            503.0979919433594,
            521.2219848632812,
            612.9819946289062
          ],
          "text": "  \nTenders must be enclosed in sealed envelopes and endorsed on the \noutside with the advertised tender number , the description and \nclosing date. The bids shall be dropped in the tender box located at \nthe above stated address by the closing date and time personally or \nby post. Upon bid submission, bidders must obtain a bid submission \nreceipt as proof of bid acceptance. Bidders are free to witness the \nopening of the tenders on the named closing date and time. \n"
        },
        {
          "bbox": [
            190.85000610351562,
            619.4979858398438,
            193.85000610351562,
            632.781982421875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            639.5679931640625,
            136.6999969482422,
            652.8519897460938
          ],
          "text": "Bid opening \n"
        },
        {
          "bbox": [
            72.02400207519531,
            659.1279907226562,
            510.3700256347656,
            686.2119750976562
          ],
          "text": "Bidders and their representatives may witness the opening of bids, which will take place at \nthe submission address immediately following the deadline. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            692.9679565429688,
            75.02400207519531,
            706.251953125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            712.7679443359375,
            75.02400207519531,
            726.0519409179688
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            732.56396484375,
            75.02400207519531,
            745.8479614257812
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            752.3639526367188,
            75.02400207519531,
            765.64794921875
          ],
          "text": " \n"
        }
      ]
    },
    {
      "index": 6,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 7 of 52 \nWithdrawal, amendment or modification of Bids \nA Bidder may withdraw, substitute, or modify its Bid after it has been submitted by sending a \nwritten notice, duly signed by an authorized representative.  However, no Bid may be \nwithdrawn, substituted, or modified in the interval between the deadline for submission of \nBids and the expiration of the period of Bid validity specified by the Bidder or any extension \nof that period. \nBid Prices and Discounts \nThe prices and discounts quoted by the Bidder in the Bid Submission Form and in the Price \nSchedules must conform to the requirements specified below. \nPrices must be quoted as specified in the Price Schedule included in Part 2 Statement of \nRequirements. In quoting prices, the Bidder is free to use transportation through carriers \nregistered in any eligible country and similarly may obtain insurance services from any \neligible country.  Prices quoted must include the following costs and components: \n(i) \nthe price must be quoted DDP(2020) that is inclusive of freight costs,insurance \ncosts(risk),import duties and taxes till delivery. \n \nPayment of tender fees \nAll foreign bidders are expected to pay for any fees or the bid bond in the currency of their \nbids while local bidders shall pay in local currency only. \n \nBid Security \nEvery bidder is required to include bid security as follows: \n \nBid Bond/Security \n \nThe Bid bond for this tender shall be RTGS$150,000.00.00(local bidders) and  payable using \nthe following options (S.I 5 of 2018 section 26).Please note that foreign bidders must provide \nthe bid bond of equivalent value in the currency of their bid. \n Option 1 \nA certified bank cheque; or \n Option 2 \nA bank guarantee; or \n \nOption 3 \nA cash deposit to Procurement Regulatory Authority of Zimbabwe (PRAZ) \nNB:  If Option 3 is chosen please note that the Tenderer must pay a non-refundable \nBid Bond/Bid security establishment fee equivalent to ZW$30,000.00(local bidders) and \nUSD350.00 (Foreign bidders) to the Procurement Regulatory Authority of Zimbabwe in \nline with S.I. 299 of 2021  PART V item 4.  \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            316.239990234375,
            810.3273315429688
          ],
          "text": " \nPage 7 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.88801574707031,
            324.42999267578125,
            100.1720199584961
          ],
          "text": "Withdrawal, amendment or modification of Bids \n"
        },
        {
          "bbox": [
            72.02400207519531,
            106.44801330566406,
            524.800048828125,
            174.9319610595703
          ],
          "text": "A Bidder may withdraw, substitute, or modify its Bid after it has been submitted by sending a \nwritten notice, duly signed by an authorized representative.  However, no Bid may be \nwithdrawn, substituted, or modified in the interval between the deadline for submission of \nBids and the expiration of the period of Bid validity specified by the Bidder or any extension \nof that period. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            184.68800354003906,
            202.72999572753906,
            197.9720001220703
          ],
          "text": "Bid Prices and Discounts \n"
        },
        {
          "bbox": [
            72.02400207519531,
            207.2480010986328,
            526.1160278320312,
            234.3319854736328
          ],
          "text": "The prices and discounts quoted by the Bidder in the Bid Submission Form and in the Price \nSchedules must conform to the requirements specified below. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            240.8479766845703,
            526.43798828125,
            295.5619812011719
          ],
          "text": "Prices must be quoted as specified in the Price Schedule included in Part 2 Statement of \nRequirements. In quoting prices, the Bidder is free to use transportation through carriers \nregistered in any eligible country and similarly may obtain insurance services from any \neligible country.  Prices quoted must include the following costs and components: \n"
        },
        {
          "bbox": [
            115.94000244140625,
            301.9100341796875,
            526.3779907226562,
            329.1620178222656
          ],
          "text": "(i) \nthe price must be quoted DDP(2020) that is inclusive of freight costs,insurance \ncosts(risk),import duties and taxes till delivery. \n"
        },
        {
          "bbox": [
            142.94000244140625,
            335.6780090332031,
            145.94000244140625,
            348.9620056152344
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            355.718017578125,
            192.0500030517578,
            369.00201416015625
          ],
          "text": "Payment of tender fees \n"
        },
        {
          "bbox": [
            72.02400207519531,
            375.27801513671875,
            510.67401123046875,
            402.36199951171875
          ],
          "text": "All foreign bidders are expected to pay for any fees or the bid bond in the currency of their \nbids while local bidders shall pay in local currency only. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            409.1180114746094,
            75.02400207519531,
            422.4020080566406
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            428.9179992675781,
            138.74000549316406,
            442.2019958496094
          ],
          "text": "Bid Security \n"
        },
        {
          "bbox": [
            72.02400207519531,
            448.4980163574219,
            356.7099914550781,
            478.5820007324219
          ],
          "text": "Every bidder is required to include bid security as follows: \n \n"
        },
        {
          "bbox": [
            128.66000366210938,
            479.3380126953125,
            226.00999450683594,
            492.62200927734375
          ],
          "text": "Bid Bond/Security \n"
        },
        {
          "bbox": [
            72.02400207519531,
            493.13800048828125,
            526.5399780273438,
            547.5819702148438
          ],
          "text": " \nThe Bid bond for this tender shall be RTGS$150,000.00.00(local bidders) and  payable using \nthe following options (S.I 5 of 2018 section 26).Please note that foreign bidders must provide \nthe bid bond of equivalent value in the currency of their bid. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            548.3380126953125,
            213.0500030517578,
            575.1819458007812
          ],
          "text": " Option 1 \nA certified bank cheque; or \n"
        },
        {
          "bbox": [
            72.02400207519531,
            575.93798828125,
            526.5399780273438,
            741.0519409179688
          ],
          "text": " Option 2 \nA bank guarantee; or \n \nOption 3 \nA cash deposit to Procurement Regulatory Authority of Zimbabwe (PRAZ) \nNB:  If Option 3 is chosen please note that the Tenderer must pay a non-refundable \nBid Bond/Bid security establishment fee equivalent to ZW$30,000.00(local bidders) and \nUSD350.00 (Foreign bidders) to the Procurement Regulatory Authority of Zimbabwe in \nline with S.I. 299 of 2021  PART V item 4.  \n \n \n \n"
        }
      ]
    },
    {
      "index": 7,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 8 of 52 \nAny bid not accompanied by a Bid Security or Bid Securing Declaration, where this is a \nrequirement of bidding, will be rejected by the Procuring Entity as non-responsive. \nThe Bid Security or Bid- Securing Declaration of a Joint Venture (JV) must be in the name of \nthe JV that submits the Bid.  If the JV has not been legally constituted at the time of bidding, \nthe Bid Security or Bid-Securing Declaration must be in the names of all intended partners. \nContract Administration Fees \nThe winning bidder(s) shall be required to pay applicable contract administration fees to \nPRAZ in terms of part VI of Statutory Instrument (S.I) 299 of 2021 before contract signature. \nBidders must study and understand the fees structure provided in S.I 299 of 2021. \n \nAdministration fees payable by bidders for bids subject to review (SPOC fees) \nThe tender is subject to review in terms of Section 54 of the Act,therefore bidders shall be \nrequired to pay the following fees in terms of Part IV of S.I 299 of 2021: \n Equivalent of ZW$30,000.00 for local bidders and USD$400.00 for foreign bidders . \nBidders must attach proof of compliance on the bid documents without fail. \n \nEvaluation of Bids \nBids will be evaluated using the following methodology:  \n1. Preliminary examination to confirm that all documents required have been provided, to \nconfirm the eligibility of Bidders in terms of section 28 (1) of the Regulations and to \nconfirm that the Bid is administratively compliant in terms of section 28 (2) of the \nRegulations.  \n2. Technical evaluation to determine substantial responsiveness to the specifications in the \nStatement of Requirements;  \n3. Financial evaluation and comparison to determine the evaluated price of bids and to \ndetermine the lowest evaluated bid.  \nBids shall be fully evaluated for all the stages and bids failing on any stage shall be rejected. \n \nReview by the Special Procurement Oversight Committee \nSection 54 of the Act provides for review by the Special Procurement Oversight Committee \nfor certain especially sensitive or especially valuable contracts. The tender is subject to review \ntherefore three identical copies of the bid document are required and that, where the copies \nare not identical, the contents of the bid marked original will alone be considered. \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            316.239990234375,
            810.3273315429688
          ],
          "text": " \nPage 8 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            497.927978515625,
            113.73201751708984
          ],
          "text": "Any bid not accompanied by a Bid Security or Bid Securing Declaration, where this is a \nrequirement of bidding, will be rejected by the Procuring Entity as non-responsive. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            120.24800109863281,
            524.9539184570312,
            161.13197326660156
          ],
          "text": "The Bid Security or Bid- Securing Declaration of a Joint Venture (JV) must be in the name of \nthe JV that submits the Bid.  If the JV has not been legally constituted at the time of bidding, \nthe Bid Security or Bid-Securing Declaration must be in the names of all intended partners. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            167.8880157470703,
            228.2899932861328,
            181.17201232910156
          ],
          "text": "Contract Administration Fees \n"
        },
        {
          "bbox": [
            72.02400207519531,
            187.44801330566406,
            524.02001953125,
            228.3319854736328
          ],
          "text": "The winning bidder(s) shall be required to pay applicable contract administration fees to \nPRAZ in terms of part VI of Statutory Instrument (S.I) 299 of 2021 before contract signature. \nBidders must study and understand the fees structure provided in S.I 299 of 2021. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            234.8479766845703,
            75.02400207519531,
            248.13197326660156
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            254.8880157470703,
            474.1000061035156,
            268.1720275878906
          ],
          "text": "Administration fees payable by bidders for bids subject to review (SPOC fees) \n"
        },
        {
          "bbox": [
            72.02400207519531,
            274.4779968261719,
            507.17803955078125,
            301.5619812011719
          ],
          "text": "The tender is subject to review in terms of Section 54 of the Act,therefore bidders shall be \nrequired to pay the following fees in terms of Part IV of S.I 299 of 2021: \n"
        },
        {
          "bbox": [
            90.02400207519531,
            307.66998291015625,
            518.6199951171875,
            322.3219909667969
          ],
          "text": " Equivalent of ZW$30,000.00 for local bidders and USD$400.00 for foreign bidders . \n"
        },
        {
          "bbox": [
            108.0199966430664,
            322.718017578125,
            474.4599914550781,
            336.00201416015625
          ],
          "text": "Bidders must attach proof of compliance on the bid documents without fail. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            342.51800537109375,
            75.02400207519531,
            355.802001953125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            362.5580139160156,
            169.6999969482422,
            375.8420104980469
          ],
          "text": "Evaluation of Bids \n"
        },
        {
          "bbox": [
            72.02400207519531,
            382.1180114746094,
            351.07000732421875,
            395.4020080566406
          ],
          "text": "Bids will be evaluated using the following methodology:  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            401.75,
            511.2959899902344,
            456.60198974609375
          ],
          "text": "1. Preliminary examination to confirm that all documents required have been provided, to \nconfirm the eligibility of Bidders in terms of section 28 (1) of the Regulations and to \nconfirm that the Bid is administratively compliant in terms of section 28 (2) of the \nRegulations.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            462.9700012207031,
            514.823974609375,
            490.2220153808594
          ],
          "text": "2. Technical evaluation to determine substantial responsiveness to the specifications in the \nStatement of Requirements;  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            496.57000732421875,
            495.4580078125,
            523.8219604492188
          ],
          "text": "3. Financial evaluation and comparison to determine the evaluated price of bids and to \ndetermine the lowest evaluated bid.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            530.3380126953125,
            518.5,
            543.6220092773438
          ],
          "text": "Bids shall be fully evaluated for all the stages and bids failing on any stage shall be rejected. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            550.3779907226562,
            75.02400207519531,
            563.6619873046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            570.177978515625,
            370.3900146484375,
            583.4619750976562
          ],
          "text": "Review by the Special Procurement Oversight Committee \n"
        },
        {
          "bbox": [
            72.02400207519531,
            589.7379760742188,
            528.1300659179688,
            644.4219360351562
          ],
          "text": "Section 54 of the Act provides for review by the Special Procurement Oversight Committee \nfor certain especially sensitive or especially valuable contracts. The tender is subject to review \ntherefore three identical copies of the bid document are required and that, where the copies \nare not identical, the contents of the bid marked original will alone be considered. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            651.2080078125,
            75.02400207519531,
            664.4920043945312
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            671.0079956054688,
            75.02400207519531,
            684.2919921875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            690.8079833984375,
            75.02400207519531,
            704.0919799804688
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            710.6079711914062,
            75.02400207519531,
            723.8919677734375
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            730.407958984375,
            75.02400207519531,
            743.6919555664062
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            750.2039794921875,
            75.02400207519531,
            763.4879760742188
          ],
          "text": " \n"
        }
      ]
    },
    {
      "index": 8,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 9 of 52 \n \nEvaluation criteria \nThe Procuring Entity’s evaluation of a Bid will take into account, in addition to the Bid Price, \nthe following criteria and methodologies.  \n(a) Compliance to technical specifications-Bidders must fully comply with the technical \nspecifications provided in this tender. Bidders who hold the transformers ex stock are \nexempted from completing the technical guarantee schedule only if they attach \nproof of quality inspection certificates issued  by Zesa Enterprises(ZENT). The \nexemption shall apply only to the transformers held in stock. \n(b) Price and pricing format-Bidders should submit their bid prices with the following \nformat. Failure to follow the format below may lead to disqualification of the bid: \nLot  \nNo \nDescription of \ntransformer \nQty \nUnit \nPrice \nExcluding VAT \nZWS$ \nTotal \n14.5% VAT \nZW$ \nTotal Including  \nVAT ZW$ \n1 \n Transformers \nXx \n \n \n \n2 \nTransformers \nXx \n \n \n \n3 \nTransformers \nxx \n \n \n \n4 \nTransformers \nxx \n \n \n \n \n \nBidders are free to quote for one or more lots \n       \n Payment shall be strictly in local currency only. \n The bid price should clearly and separately show the unit price and the  \ntotal price of the to be supplied. \n The ZW$ prices shall be used for purposes of tender evaluation. \n Bidders MUST state clearly whether they charge VAT or not. \n \n(c) Should REF receive bids in different currencies , the currency of evaluation will be the \nlocal currency(ZW$) .  NOTE: Local bidders must quote in local currency only .See \npricing format provided. However foreign  bidders are required to convert their bids into \nlocal currency using the RBZ exchange rate (mid-rate) obtaining on 16 March 2022.  See \nhttp://www.rbz.co.zw/.  \nWhere foreign bids are not converted into local currency REF shall convert the bids into \nlocal currency for purposes of tender evaluation using the RBZ exchange rate obtaining \non the 16 March 2022 as above. However REF may reject bids quoted in foreign \ncurrency without conversion into local currency. REF reserves the right to amend the \ntender quantity during evaluation in line with budgetary provisions and or other \nconsiderations. \n(d) Delivery schedule: Successful bidder(s) shall be required to deliver the transformers  \nfive(5) days from the date of contract signing or from the date a purchase order is issued, \nwhichever comes first. The delivery address for the tender shall be: \n REF Central Stores No.22A James Martin Road, Lochinvar Harare Zimbabwe. REF \nreserves the right to reject the right to reject any deliveries or products that do not \nmeet the technical specifications provided in this tender. \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            316.239990234375,
            810.3273315429688
          ],
          "text": " \nPage 9 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.88801574707031,
            238.6999969482422,
            129.26864624023438
          ],
          "text": " \nEvaluation criteria \n"
        },
        {
          "bbox": [
            72.02400207519531,
            135.4879913330078,
            524.738037109375,
            162.5719757080078
          ],
          "text": "The Procuring Entity’s evaluation of a Bid will take into account, in addition to the Bid Price, \nthe following criteria and methodologies.  \n"
        },
        {
          "bbox": [
            79.10399627685547,
            168.9199676513672,
            506.2460632324219,
            182.37196350097656
          ],
          "text": "(a) Compliance to technical specifications-Bidders must fully comply with the technical \n"
        },
        {
          "bbox": [
            97.10399627685547,
            182.31201171875,
            526.8259887695312,
            237.8119659423828
          ],
          "text": "specifications provided in this tender. Bidders who hold the transformers ex stock are \nexempted from completing the technical guarantee schedule only if they attach \nproof of quality inspection certificates issued  by Zesa Enterprises(ZENT). The \nexemption shall apply only to the transformers held in stock. \n"
        },
        {
          "bbox": [
            79.10399627685547,
            243.9199676513672,
            495.6019287109375,
            257.3719787597656
          ],
          "text": "(b) Price and pricing format-Bidders should submit their bid prices with the following \n"
        },
        {
          "bbox": [
            72.02400207519531,
            257.7680358886719,
            492.82000732421875,
            299.7931823730469
          ],
          "text": "format. Failure to follow the format below may lead to disqualification of the bid: \nLot  \nNo \n"
        },
        {
          "bbox": [
            100.33999633789062,
            274.4434509277344,
            177.9070281982422,
            299.7931823730469
          ],
          "text": "Description of \ntransformer \n"
        },
        {
          "bbox": [
            185.4499969482422,
            274.4434509277344,
            298.4169921875,
            312.6332092285156
          ],
          "text": "Qty \nUnit \nPrice \nExcluding VAT \nZWS$ \n"
        },
        {
          "bbox": [
            305.95001220703125,
            274.4434509277344,
            369.2730407714844,
            312.6332092285156
          ],
          "text": "Total \n14.5% VAT \nZW$ \n"
        },
        {
          "bbox": [
            376.8699951171875,
            274.4434509277344,
            459.90301513671875,
            299.7931823730469
          ],
          "text": "Total Including  \nVAT ZW$ \n"
        },
        {
          "bbox": [
            72.02400207519531,
            313.2034606933594,
            380.1930236816406,
            413.8699951171875
          ],
          "text": "1 \n Transformers \nXx \n \n \n \n2 \nTransformers \nXx \n \n \n \n3 \nTransformers \nxx \n \n \n \n4 \nTransformers \nxx \n \n \n \n \n \nBidders are free to quote for one or more lots \n       \n"
        },
        {
          "bbox": [
            90.02400207519531,
            413.989990234375,
            505.1919860839844,
            443.4020080566406
          ],
          "text": " Payment shall be strictly in local currency only. \n The bid price should clearly and separately show the unit price and the  \n"
        },
        {
          "bbox": [
            90.02400207519531,
            443.46197509765625,
            455.99200439453125,
            486.74200439453125
          ],
          "text": "total price of the to be supplied. \n The ZW$ prices shall be used for purposes of tender evaluation. \n Bidders MUST state clearly whether they charge VAT or not. \n"
        },
        {
          "bbox": [
            79.10399627685547,
            486.9219970703125,
            516.98193359375,
            517.8219604492188
          ],
          "text": " \n(c) Should REF receive bids in different currencies , the currency of evaluation will be the \n"
        },
        {
          "bbox": [
            97.10399627685547,
            518.3380126953125,
            528.2080688476562,
            573.02197265625
          ],
          "text": "local currency(ZW$) .  NOTE: Local bidders must quote in local currency only .See \npricing format provided. However foreign  bidders are required to convert their bids into \nlocal currency using the RBZ exchange rate (mid-rate) obtaining on 16 March 2022.  See \nhttp://www.rbz.co.zw/.  \n"
        },
        {
          "bbox": [
            97.10399627685547,
            579.5379638671875,
            524.0140380859375,
            661.8519897460938
          ],
          "text": "Where foreign bids are not converted into local currency REF shall convert the bids into \nlocal currency for purposes of tender evaluation using the RBZ exchange rate obtaining \non the 16 March 2022 as above. However REF may reject bids quoted in foreign \ncurrency without conversion into local currency. REF reserves the right to amend the \ntender quantity during evaluation in line with budgetary provisions and or other \nconsiderations. \n"
        },
        {
          "bbox": [
            79.10399627685547,
            668.2000122070312,
            510.1820068359375,
            681.6519775390625
          ],
          "text": "(d) Delivery schedule: Successful bidder(s) shall be required to deliver the transformers  \n"
        },
        {
          "bbox": [
            97.10399627685547,
            682.16796875,
            526.7659301757812,
            709.251953125
          ],
          "text": "five(5) days from the date of contract signing or from the date a purchase order is issued, \nwhichever comes first. The delivery address for the tender shall be: \n"
        },
        {
          "bbox": [
            90.02400207519531,
            715.3599853515625,
            515.2479858398438,
            730.011962890625
          ],
          "text": " REF Central Stores No.22A James Martin Road, Lochinvar Harare Zimbabwe. REF \n"
        },
        {
          "bbox": [
            108.0199966430664,
            730.407958984375,
            502.5940246582031,
            757.4879760742188
          ],
          "text": "reserves the right to reject the right to reject any deliveries or products that do not \nmeet the technical specifications provided in this tender. \n"
        }
      ]
    },
    {
      "index": 9,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 10 of 52 \n(e) Payment terms-Bidders must state the preferred payment terms \nHowever REF shall pay the winning bidder whether it’s a local bidder or foreign bidder in \nlocal currency(ZW$) only: \n \nPrepayment -REF favors payment after delivery, however where a bidder \nrequire pre-delivery payment  they must state ability to secure a bank guarantee from \na registered commercial bank acceptable to REF equal to the amount to be advanced. \nThe bank guarantee must be provided within two weeks of contract signing.  \n          NOTE: Foreign bidders must provide a bank guarantee confirmed by any  \n          local commercial banks or provide a bank guarantee issued by any local banks.  \n(f)   Bidders must state whether the transformers are imported or are locally   \n          manufactured without fail. State the country of origin without fail. \n(g) Bidders should provide their local bank account details without fail. \n(h)  Delivery term shall be Delivered Duty Paid(DDP)(2020),Harare Central Stores-That is \nInclusive of freight costs, transit  insurance (risk),all import duties and costs until \ndelivery at REF Central Stores No.22A James Martin Road, Lochinvar Harare \nZimbabwe.-Bidders MUST state that the delivery term shall be DDP(2020) Central \nStores No.22A James Martin Road, Lochinvar Harare Zimbabwe. \n(i) The transformers shall be tested by Zesa Enterprises Engineers before they are received \nby REF Central Stores at the supplier’s cost. REF reserves the right to reject goods that \ndo not meet the required tender specifications.    \n(j)   Bidders must be registered with the Procurement Regulatory Authority of \n    Zimbabwe(PRAZ)- Bidders must attach proof of registration with PRAZ on the \n    list for supply of electricals/hardware. However foreign bidders shall only be required \nto register with PRAZ if awarded the tender and before contract signature. \n(k)   Letter of agency-non-manufacturers must attach a letter of agency from the \n         manufacturer with the bid documents without fail. \n(L) Product brochure- Bidders are required to attach a product brochure for the transformers \n       tendered without fail. \n(m)  Valid ISO certificate of the manufacturer of the transformers must be  \n  provided- Bidders must attach proof without fail. \n(n)   Foreign bidders must clearly state in their bids that they have checked that  the \ntransformers  tendered “fall” or “do not fall” under the Consignment Based Conformity \nAssessment (CBCA) programme as required by  the Government of Zimbabwe. If the goods \ntendered “fall” under the CBCA programme, bidders must further state that all costs \nassociated with this requirement will be to the supplier’s account. Bidders who hold the \ntransformers ex-stock do not need to comply with this requirement. \n(o)    Delivery period. The winning bidder(s)  shall be required to deliver the transformers \nwithin a period five(5) days the date of contract signing or the date a purchase order is \nissued whichever comes first. Bidders must  state their capacity to deliver within a \nperiod of five(5) days as required. \n(p)    Reference letters-Bidders must attach at least two reference letters from  \n companies where the bidder has supplied transformers over the past two years. Reference \nletters referring to supplies done more than two years old will not be acceptable. \n(q)    Bidders must state a warranty period of 12 months for the supplied items. \n (r)  Bid bond compliance-Bidders must attach proof of bid bod compliance as per   \n  Part one of this bidding document without fail. \n(s ) Compliance with Administration fees payable by bidders for bids subject to review  \n     (SPOC fees)-Bidders must attach proof of payment for SPOC administration fees as per \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 10 of 52 \n"
        },
        {
          "bbox": [
            79.10399627685547,
            86.64796447753906,
            431.739990234375,
            99.93196868896484
          ],
          "text": "(e) Payment terms-Bidders must state the preferred payment terms \n"
        },
        {
          "bbox": [
            79.10399627685547,
            106.44801330566406,
            515.52197265625,
            119.73201751708984
          ],
          "text": "However REF shall pay the winning bidder whether it’s a local bidder or foreign bidder in \n"
        },
        {
          "bbox": [
            100.33999633789062,
            120.24800109863281,
            232.00999450683594,
            133.53199768066406
          ],
          "text": "local currency(ZW$) only: \n"
        },
        {
          "bbox": [
            72.02400207519531,
            136.6400146484375,
            526.5399780273438,
            220.41200256347656
          ],
          "text": " \nPrepayment -REF favors payment after delivery, however where a bidder \nrequire pre-delivery payment  they must state ability to secure a bank guarantee from \na registered commercial bank acceptable to REF equal to the amount to be advanced. \nThe bank guarantee must be provided within two weeks of contract signing.  \n          NOTE: Foreign bidders must provide a bank guarantee confirmed by any  \n          local commercial banks or provide a bank guarantee issued by any local banks.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            220.52000427246094,
            454.05999755859375,
            247.77198791503906
          ],
          "text": "(f)   Bidders must state whether the transformers are imported or are locally   \n          manufactured without fail. State the country of origin without fail. \n"
        },
        {
          "bbox": [
            79.10399627685547,
            248.11997985839844,
            520.2760620117188,
            275.3719787597656
          ],
          "text": "(g) Bidders should provide their local bank account details without fail. \n(h)  Delivery term shall be Delivered Duty Paid(DDP)(2020),Harare Central Stores-That is \n"
        },
        {
          "bbox": [
            79.10399627685547,
            275.9179992675781,
            520.4400634765625,
            344.4020080566406
          ],
          "text": "Inclusive of freight costs, transit  insurance (risk),all import duties and costs until \ndelivery at REF Central Stores No.22A James Martin Road, Lochinvar Harare \nZimbabwe.-Bidders MUST state that the delivery term shall be DDP(2020) Central \nStores No.22A James Martin Road, Lochinvar Harare Zimbabwe. \n(i) The transformers shall be tested by Zesa Enterprises Engineers before they are received \n"
        },
        {
          "bbox": [
            72.02400207519531,
            344.9179992675781,
            518.739990234375,
            385.802001953125
          ],
          "text": "by REF Central Stores at the supplier’s cost. REF reserves the right to reject goods that \ndo not meet the required tender specifications.    \n(j)   Bidders must be registered with the Procurement Regulatory Authority of \n"
        },
        {
          "bbox": [
            72.02400207519531,
            386.3179931640625,
            517.6599731445312,
            496.2220153808594
          ],
          "text": "    Zimbabwe(PRAZ)- Bidders must attach proof of registration with PRAZ on the \n    list for supply of electricals/hardware. However foreign bidders shall only be required \nto register with PRAZ if awarded the tender and before contract signature. \n(k)   Letter of agency-non-manufacturers must attach a letter of agency from the \n         manufacturer with the bid documents without fail. \n(L) Product brochure- Bidders are required to attach a product brochure for the transformers \n       tendered without fail. \n(m)  Valid ISO certificate of the manufacturer of the transformers must be  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            496.8580017089844,
            518.968017578125,
            593.9019775390625
          ],
          "text": "  provided- Bidders must attach proof without fail. \n(n)   Foreign bidders must clearly state in their bids that they have checked that  the \ntransformers  tendered “fall” or “do not fall” under the Consignment Based Conformity \nAssessment (CBCA) programme as required by  the Government of Zimbabwe. If the goods \ntendered “fall” under the CBCA programme, bidders must further state that all costs \nassociated with this requirement will be to the supplier’s account. Bidders who hold the \ntransformers ex-stock do not need to comply with this requirement. \n"
        },
        {
          "bbox": [
            90.02400207519531,
            594.25,
            524.7140502929688,
            607.7019653320312
          ],
          "text": "(o)    Delivery period. The winning bidder(s)  shall be required to deliver the transformers \n"
        },
        {
          "bbox": [
            72.02400207519531,
            608.2179565429688,
            525.4240112304688,
            718.1319580078125
          ],
          "text": "within a period five(5) days the date of contract signing or the date a purchase order is \nissued whichever comes first. Bidders must  state their capacity to deliver within a \nperiod of five(5) days as required. \n(p)    Reference letters-Bidders must attach at least two reference letters from  \n companies where the bidder has supplied transformers over the past two years. Reference \nletters referring to supplies done more than two years old will not be acceptable. \n(q)    Bidders must state a warranty period of 12 months for the supplied items. \n (r)  Bid bond compliance-Bidders must attach proof of bid bod compliance as per   \n"
        },
        {
          "bbox": [
            72.02400207519531,
            718.64794921875,
            512.1400146484375,
            759.5279541015625
          ],
          "text": "  Part one of this bidding document without fail. \n(s ) Compliance with Administration fees payable by bidders for bids subject to review  \n     (SPOC fees)-Bidders must attach proof of payment for SPOC administration fees as per \n"
        }
      ]
    },
    {
      "index": 10,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 11 of 52 \n     part one of this bidding document. \n(t)  Bid validity of a minimum of 90 days is required and must be clearly stated. \n (u)  The Bidders must submit the bid with a duly filled in and signed Declaration  \n         On Non-Engagement in Corrupt or Fraudulent Practices Form Annexure 2. \n(v)  The bidder must submit with the bid a duly filled in and signed attached Form    \n        of Tender Annexure 3. \n(w)  Attach the bid submission form attached on page 13 of this document. Bids without the \nbid submission form may be rejected. \n \nEligibility and Qualification Criteria \nBidders are required to meet the criteria in section 28 of the Act to be eligible to participate in \npublic procurement and to be qualified for the proposed contract.  To be eligible, Bidders \nmust: \n1. have the legal capacity to enter into a contract; \n2. not be insolvent, in receivership, bankrupt or being wound up, not have had business \nactivities suspended and not be the subject of legal proceedings for any of these \ncircumstances; \n3. not have a conflict of interest in relation to this procurement requirement;  \n4. not been debarred from participation in public procurement under section 72 (6) of the \nAct and section 74(1) (c), (d) or (e) of the Regulations or declared ineligible under section \n99 of the Act; \n5. have the nationality of an eligible country as specified in the Special Conditions of \nContract; and \nParticipation in this bidding procedure is open to both Zimbabwean and foreign bidders.  \n \nOrigin of Goods \nAll goods and related services must have as their country of origin an eligible country, as \nspecified in the Special Conditions of Contract.  \n \nTechnical Criteria \nThe Technical Specifications Sheet details the minimum specification of the goods required.  \nThe goods offered must meet this specification, but no credit will be given for exceeding the \nspecification.  \n \nAward of Tender Criteria \nTender shall be awarded to the lowest priced bidder to specification who hold the tendered \nitems ex-stock. Where the winning bidder holds less-than the tender quantity, REF may \naward the tender for one lot to different bidders who hold the transformers ex-stock until the \ntender quantity is fulfilled. Bidders who hold the transformers ex-stock must state that they \nhold the goods ex stock without fail and the quantity held in stock.  \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 11 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            516.699951171875,
            196.53199768066406
          ],
          "text": "     part one of this bidding document. \n(t)  Bid validity of a minimum of 90 days is required and must be clearly stated. \n (u)  The Bidders must submit the bid with a duly filled in and signed Declaration  \n         On Non-Engagement in Corrupt or Fraudulent Practices Form Annexure 2. \n(v)  The bidder must submit with the bid a duly filled in and signed attached Form    \n        of Tender Annexure 3. \n(w)  Attach the bid submission form attached on page 13 of this document. Bids without the \nbid submission form may be rejected. \n"
        },
        {
          "bbox": [
            79.10399627685547,
            200.04798889160156,
            82.10399627685547,
            213.3319854736328
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            220.0879669189453,
            262.7300109863281,
            233.37196350097656
          ],
          "text": "Eligibility and Qualification Criteria \n"
        },
        {
          "bbox": [
            72.02400207519531,
            239.64796447753906,
            525.4700317382812,
            280.5619812011719
          ],
          "text": "Bidders are required to meet the criteria in section 28 of the Act to be eligible to participate in \npublic procurement and to be qualified for the proposed contract.  To be eligible, Bidders \nmust: \n"
        },
        {
          "bbox": [
            72.02400207519531,
            286.9100341796875,
            316.989990234375,
            300.3620300292969
          ],
          "text": "1. have the legal capacity to enter into a contract; \n"
        },
        {
          "bbox": [
            72.02400207519531,
            306.71002197265625,
            499.5699768066406,
            347.7619934082031
          ],
          "text": "2. not be insolvent, in receivership, bankrupt or being wound up, not have had business \nactivities suspended and not be the subject of legal proceedings for any of these \ncircumstances; \n"
        },
        {
          "bbox": [
            72.02400207519531,
            354.1100158691406,
            449.0199890136719,
            367.56201171875
          ],
          "text": "3. not have a conflict of interest in relation to this procurement requirement;  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            373.9100036621094,
            525.239990234375,
            414.9620056152344
          ],
          "text": "4. not been debarred from participation in public procurement under section 72 (6) of the \nAct and section 74(1) (c), (d) or (e) of the Regulations or declared ineligible under section \n99 of the Act; \n"
        },
        {
          "bbox": [
            72.02400207519531,
            421.30999755859375,
            489.73199462890625,
            448.56201171875
          ],
          "text": "5. have the nationality of an eligible country as specified in the Special Conditions of \nContract; and \n"
        },
        {
          "bbox": [
            72.02400207519531,
            455.0979919433594,
            502.4200134277344,
            468.3819885253906
          ],
          "text": "Participation in this bidding procedure is open to both Zimbabwean and foreign bidders.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            475.13800048828125,
            75.02400207519531,
            488.4219970703125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            494.9380187988281,
            157.6999969482422,
            508.2220153808594
          ],
          "text": "Origin of Goods \n"
        },
        {
          "bbox": [
            72.02400207519531,
            514.4979858398438,
            502.7540588378906,
            541.5819702148438
          ],
          "text": "All goods and related services must have as their country of origin an eligible country, as \nspecified in the Special Conditions of Contract.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            548.3380126953125,
            75.02400207519531,
            561.6220092773438
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            568.137939453125,
            169.33999633789062,
            581.4219360351562
          ],
          "text": "Technical Criteria \n"
        },
        {
          "bbox": [
            72.02400207519531,
            587.697998046875,
            521.97998046875,
            628.5819702148438
          ],
          "text": "The Technical Specifications Sheet details the minimum specification of the goods required.  \nThe goods offered must meet this specification, but no credit will be given for exceeding the \nspecification.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            635.3679809570312,
            75.02400207519531,
            648.6519775390625
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            655.16796875,
            208.00999450683594,
            668.4519653320312
          ],
          "text": "Award of Tender Criteria \n"
        },
        {
          "bbox": [
            72.02400207519531,
            674.7279663085938,
            518.5960083007812,
            743.2119750976562
          ],
          "text": "Tender shall be awarded to the lowest priced bidder to specification who hold the tendered \nitems ex-stock. Where the winning bidder holds less-than the tender quantity, REF may \naward the tender for one lot to different bidders who hold the transformers ex-stock until the \ntender quantity is fulfilled. Bidders who hold the transformers ex-stock must state that they \nhold the goods ex stock without fail and the quantity held in stock.  \n"
        }
      ]
    },
    {
      "index": 11,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 12 of 52 \nBidders who hold the transformers ex-stock MUST attach ZENT quality check certificates as \nproof of ex stock status. Bids without ZENT certificates shall be treated as non-stock holders \nduring evaluation. \nREF reserves the right to visit bidders premises and inspect the items stated as EX-STOCK \nand findings by the visiting team shall be used for evaluation of this tender. NB: BIDDERS \nWHO FALSELY CLAIM TO HOLD STOCK SHALL BE DISQUALIFIED FROM \nTHE TENDER PROCESS. Bidders are allowed to quote for the full or part tender quantity.  \nBidders who do not hold the transformers ex stock shall be disqualified as non-compliant. \nThe proposed award of contract will be by issue of a Notification of Contract Award in terms \nof section 55 of the Act which will be effective until signature of the contract documents in \naccordance with Part 3: Contract.  Unsuccessful Bidders will receive the Notification of \nContract Award and, if they consider they have suffered prejudice from the process, they may \nwithin 14 days of receiving this Notification, submit to the Procuring Entity a Challenge in \nterms of section 73 of the Act, subject to payment of the applicable fee set out in section 44 \nof and the Third Schedule to the Regulations. \n \nRight to Reject \nThe Procuring Entity reserves the right to accept or reject any Bids or to cancel the \nprocurement process and reject all Bids at any time prior to contract award.  \n \nCorrupt Practices \nThe Government of Zimbabwe requires that Procuring Entities, as well as Bidders and \nContractors, observe the highest standard of ethics during the procurement and execution of \ncontracts.  In pursuit of this policy: \n1. the Procuring Entity will reject a recommendation for award if it determines that the \nBidder recommended for award has, directly or through an agent, engaged in corrupt, \nfraudulent, collusive or coercive practices in competing for the Contract or been declared \nineligible to be awarded a procurement contract under section 99 of the Act; \n2. the Authority may under section 72 (6) of the Act impose the sanctions under section 74 \n(1) of the Regulations; and any conflict of interest on the part of the Bidder must be \ndeclared. \n \n \n \n \n \n \n \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 12 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            522.674072265625,
            127.5320053100586
          ],
          "text": "Bidders who hold the transformers ex-stock MUST attach ZENT quality check certificates as \nproof of ex stock status. Bids without ZENT certificates shall be treated as non-stock holders \nduring evaluation. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            134.04798889160156,
            526.0599975585938,
            188.7320098876953
          ],
          "text": "REF reserves the right to visit bidders premises and inspect the items stated as EX-STOCK \nand findings by the visiting team shall be used for evaluation of this tender. NB: BIDDERS \nWHO FALSELY CLAIM TO HOLD STOCK SHALL BE DISQUALIFIED FROM \nTHE TENDER PROCESS. Bidders are allowed to quote for the full or part tender quantity.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            195.2480010986328,
            506.3800048828125,
            208.53199768066406
          ],
          "text": "Bidders who do not hold the transformers ex stock shall be disqualified as non-compliant. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            215.04798889160156,
            525.5440063476562,
            311.1620178222656
          ],
          "text": "The proposed award of contract will be by issue of a Notification of Contract Award in terms \nof section 55 of the Act which will be effective until signature of the contract documents in \naccordance with Part 3: Contract.  Unsuccessful Bidders will receive the Notification of \nContract Award and, if they consider they have suffered prejudice from the process, they may \nwithin 14 days of receiving this Notification, submit to the Procuring Entity a Challenge in \nterms of section 73 of the Act, subject to payment of the applicable fee set out in section 44 \nof and the Third Schedule to the Regulations. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            317.6780090332031,
            75.02400207519531,
            330.9620056152344
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            337.718017578125,
            152.3000030517578,
            351.00201416015625
          ],
          "text": "Right to Reject \n"
        },
        {
          "bbox": [
            72.02400207519531,
            357.27801513671875,
            472.2960205078125,
            384.36199951171875
          ],
          "text": "The Procuring Entity reserves the right to accept or reject any Bids or to cancel the \nprocurement process and reject all Bids at any time prior to contract award.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            390.8780212402344,
            75.02400207519531,
            404.1620178222656
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            410.9179992675781,
            167.3000030517578,
            424.2019958496094
          ],
          "text": "Corrupt Practices \n"
        },
        {
          "bbox": [
            72.02400207519531,
            430.4779968261719,
            515.760009765625,
            471.3819885253906
          ],
          "text": "The Government of Zimbabwe requires that Procuring Entities, as well as Bidders and \nContractors, observe the highest standard of ethics during the procurement and execution of \ncontracts.  In pursuit of this policy: \n"
        },
        {
          "bbox": [
            72.02400207519531,
            477.7300109863281,
            521.1279907226562,
            532.5819702148438
          ],
          "text": "1. the Procuring Entity will reject a recommendation for award if it determines that the \nBidder recommended for award has, directly or through an agent, engaged in corrupt, \nfraudulent, collusive or coercive practices in competing for the Contract or been declared \nineligible to be awarded a procurement contract under section 99 of the Act; \n"
        },
        {
          "bbox": [
            72.02400207519531,
            538.9299926757812,
            516.384033203125,
            579.9819946289062
          ],
          "text": "2. the Authority may under section 72 (6) of the Act impose the sanctions under section 74 \n(1) of the Regulations; and any conflict of interest on the part of the Bidder must be \ndeclared. \n"
        },
        {
          "bbox": [
            304.8699951171875,
            583.4979858398438,
            307.8699951171875,
            762.407958984375
          ],
          "text": " \n \n \n \n \n \n \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 12,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 13 of 52 \n \n \n                                     Bid Submission Sheet \n{Note to Bidders: Complete this form with all the requested details and submit it as the first \npage of your Bid.  Attach the completed Statement of Requirements and any other documents \nrequested in Part 1.  Ensure that your Bid is authorised in the signature block below.  A \nsignature and authorisation on this form will confirm that the terms and conditions of this \nBid prevail over any attachments.  If your Bid is not authorised, it may be rejected.  If the \nBidder is a Joint Venture (JV), the Bid must be signed by an authorized representative of the \nJV on behalf of the JV, and so as to be legally binding on all the members as evidenced by a \npower of attorney signed by their legally authorized representatives.  \nBidders must mark as “CONFIDENTIAL” information in their Bids which is confidential to \ntheir business.  This may include proprietary information, trade secrets or commercial or \nfinancially sensitive information}.  \n \nProcurement Reference Number: \n \nSubject of Procurement: \n \nName of Bidder: \n \nBidder’s Reference Number: \n \nDate of Bid: \n \nWe offer to supply the items listed in the attached Statement of Requirements, at the prices \nindicated on the attached Price Schedule and in accordance with the terms and conditions \nstated in your Bidding Document referenced above.  \nWe confirm that we meet the eligibility criteria specified in Part 1: Procedures of Bidding.  \nWe declare that we are not debarred from bidding and that the documents we submit are true \nand correct. \nThe validity period of our bid is: ……… {days} from the date of submission.  \nWe confirm that the prices quoted in the attached Price Schedule are fixed and firm for the \nduration of the validity period and will not be subject to revision, variation or adjustment. \nBid Authorised by: \nSignature …………………………….. \nName: …………………………………… \nPosition: \n…………………………….. \nDate: \n…………………….……(DD/MM\n/YY) \nAuthorised for and on behalf of: \n \n \nCompany …………………………………………………………………………………… \nAddress: \n…………………………………………………………………………………… \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 13 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            526.5399780273438,
            282.3620300292969
          ],
          "text": " \n \n                                     Bid Submission Sheet \n{Note to Bidders: Complete this form with all the requested details and submit it as the first \npage of your Bid.  Attach the completed Statement of Requirements and any other documents \nrequested in Part 1.  Ensure that your Bid is authorised in the signature block below.  A \nsignature and authorisation on this form will confirm that the terms and conditions of this \nBid prevail over any attachments.  If your Bid is not authorised, it may be rejected.  If the \nBidder is a Joint Venture (JV), the Bid must be signed by an authorized representative of the \nJV on behalf of the JV, and so as to be legally binding on all the members as evidenced by a \npower of attorney signed by their legally authorized representatives.  \nBidders must mark as “CONFIDENTIAL” information in their Bids which is confidential to \ntheir business.  This may include proprietary information, trade secrets or commercial or \nfinancially sensitive information}.  \n"
        },
        {
          "bbox": [
            77.42400360107422,
            285.8780212402344,
            80.42400360107422,
            299.1620178222656
          ],
          "text": " \n"
        },
        {
          "bbox": [
            77.42400360107422,
            305.6780090332031,
            238.97000122070312,
            318.9620056152344
          ],
          "text": "Procurement Reference Number: \n"
        },
        {
          "bbox": [
            254.69000244140625,
            285.8780212402344,
            257.69000244140625,
            299.1620178222656
          ],
          "text": " \n"
        },
        {
          "bbox": [
            77.42400360107422,
            325.4779968261719,
            257.69000244140625,
            338.7619934082031
          ],
          "text": "Subject of Procurement: \n \n"
        },
        {
          "bbox": [
            77.42400360107422,
            345.27801513671875,
            257.69000244140625,
            358.56201171875
          ],
          "text": "Name of Bidder: \n \n"
        },
        {
          "bbox": [
            77.42400360107422,
            365.0780029296875,
            257.69000244140625,
            378.36199951171875
          ],
          "text": "Bidder’s Reference Number: \n \n"
        },
        {
          "bbox": [
            77.42400360107422,
            384.8780212402344,
            257.69000244140625,
            398.1620178222656
          ],
          "text": "Date of Bid: \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            410.6780090332031,
            526.3099975585938,
            451.56201171875
          ],
          "text": "We offer to supply the items listed in the attached Statement of Requirements, at the prices \nindicated on the attached Price Schedule and in accordance with the terms and conditions \nstated in your Bidding Document referenced above.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            458.0979919433594,
            511.5400085449219,
            471.3819885253906
          ],
          "text": "We confirm that we meet the eligibility criteria specified in Part 1: Procedures of Bidding.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            477.89801025390625,
            526.4019775390625,
            504.98199462890625
          ],
          "text": "We declare that we are not debarred from bidding and that the documents we submit are true \nand correct. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            511.4980163574219,
            448.4200134277344,
            524.781982421875
          ],
          "text": "The validity period of our bid is: ……… {days} from the date of submission.  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            531.2979736328125,
            526.10400390625,
            575.4219360351562
          ],
          "text": "We confirm that the prices quoted in the attached Price Schedule are fixed and firm for the \nduration of the validity period and will not be subject to revision, variation or adjustment. \nBid Authorised by: \n"
        },
        {
          "bbox": [
            84.50399780273438,
            592.137939453125,
            536.6199951171875,
            605.6619873046875
          ],
          "text": "Signature …………………………….. \nName: …………………………………… \n"
        },
        {
          "bbox": [
            84.50399780273438,
            623.93798828125,
            533.2119750976562,
            651.0519409179688
          ],
          "text": "Position: \n…………………………….. \nDate: \n…………………….……(DD/MM\n/YY) \n"
        },
        {
          "bbox": [
            84.50399780273438,
            663.5679931640625,
            453.82000732421875,
            677.0919799804688
          ],
          "text": "Authorised for and on behalf of: \n \n \n"
        },
        {
          "bbox": [
            84.50399780273438,
            695.3679809570312,
            533.739990234375,
            708.8919677734375
          ],
          "text": "Company …………………………………………………………………………………… \n"
        },
        {
          "bbox": [
            84.50399780273438,
            721.16796875,
            533.739990234375,
            734.6919555664062
          ],
          "text": "Address: \n…………………………………………………………………………………… \n"
        },
        {
          "bbox": [
            84.50399780273438,
            746.9639892578125,
            149.66000366210938,
            760.2479858398438
          ],
          "text": " \n \n"
        }
      ]
    },
    {
      "index": 13,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 14 of 52 \n \nTechnical Specification and Compliance Sheet \nName of Bidder: \n \nBidder’s Reference Number: \n \n \n \nTECHNICAL SPECIFICATIONS FOR THE TRANSFORMERS \nInstructions to bidders \nBidders must clearly study and understand all the technical specifications provided per type \nof lot and bidders MUST complete the technical guarantee schedules for each type/lot of \ntransformer without fail. Incorrect information on the guarantee schedules shall lead to \ndisqualification of such bids. \nNB: Bidders who fail to comply with these instructions shall be disqualified. \nBidders who hold the transformers quoted ex stock are exempted from completing \nthe technical guarantee schedule ONLY if they attach proof of quality inspection \ncertificate  issued  by Zesa Enterprises(ZENT). However,the exemption shall only \napply to the transformers held ex-stock only. \n \nSummary requirements  \n \n \n \n \n11KV \n19.1 Kv \n33KV \nSIZE \n10kVA \n25Kv\na \n50kVA \n100kVA \n16 \nKva \n32 \nkVA \n64 \nkVA \n475 \nkVA \nAuto \n15kV\nA \n25 \nkVA \n50k\nVA \n100k\nVA \nTENDER \nQTY \n10 \n65 \n55 \n8 \n8 \n11 \n1 \n2 \n2 \n4 \n3 \n23 \n8 \nLOT No \n1 \n2 \n3 \n4 \n5 \n6 \n7 \n8 \n9 \n10 \n11 \n12 \n13 \n \n \n \n \n \n \n \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 14 of 52 \n"
        },
        {
          "bbox": [
            297.7699890136719,
            86.88801574707031,
            300.7699890136719,
            100.1720199584961
          ],
          "text": " \n"
        },
        {
          "bbox": [
            179.3000030517578,
            112.68800354003906,
            419.1099853515625,
            125.97200775146484
          ],
          "text": "Technical Specification and Compliance Sheet \n"
        },
        {
          "bbox": [
            77.42400360107422,
            138.2480010986328,
            257.69000244140625,
            151.53199768066406
          ],
          "text": "Name of Bidder: \n \n"
        },
        {
          "bbox": [
            77.42400360107422,
            164.04798889160156,
            257.69000244140625,
            177.3319854736328
          ],
          "text": "Bidder’s Reference Number: \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            187.0879669189453,
            75.02400207519531,
            200.37196350097656
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            206.8880157470703,
            75.02400207519531,
            220.17201232910156
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            226.68800354003906,
            401.95001220703125,
            239.9720001220703
          ],
          "text": "TECHNICAL SPECIFICATIONS FOR THE TRANSFORMERS \n"
        },
        {
          "bbox": [
            72.02400207519531,
            246.4879913330078,
            526.5399780273438,
            321.0019836425781
          ],
          "text": "Instructions to bidders \nBidders must clearly study and understand all the technical specifications provided per type \nof lot and bidders MUST complete the technical guarantee schedules for each type/lot of \ntransformer without fail. Incorrect information on the guarantee schedules shall lead to \ndisqualification of such bids. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            330.8780212402344,
            462.5799865722656,
            344.1620178222656
          ],
          "text": "NB: Bidders who fail to comply with these instructions shall be disqualified. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            353.7980041503906,
            526.5399780273438,
            466.0213623046875
          ],
          "text": "Bidders who hold the transformers quoted ex stock are exempted from completing \nthe technical guarantee schedule ONLY if they attach proof of quality inspection \ncertificate  issued  by Zesa Enterprises(ZENT). However,the exemption shall only \napply to the transformers held ex-stock only. \n \nSummary requirements  \n \n \n"
        },
        {
          "bbox": [
            20.639999389648438,
            466.4980163574219,
            464.8599853515625,
            497.06201171875
          ],
          "text": " \n \n11KV \n19.1 Kv \n33KV \n"
        },
        {
          "bbox": [
            20.639999389648438,
            508.2756652832031,
            142.87998962402344,
            530.8213500976562
          ],
          "text": "SIZE \n10kVA \n25Kv\na \n"
        },
        {
          "bbox": [
            155.4199981689453,
            508.2756652832031,
            274.94000244140625,
            530.8213500976562
          ],
          "text": "50kVA \n100kVA \n16 \nKva \n"
        },
        {
          "bbox": [
            290.0899963378906,
            508.2756652832031,
            312.6399841308594,
            530.8213500976562
          ],
          "text": "32 \nkVA \n"
        },
        {
          "bbox": [
            325.6300048828125,
            508.2756652832031,
            348.1600036621094,
            530.8213500976562
          ],
          "text": "64 \nkVA \n"
        },
        {
          "bbox": [
            360.9100036621094,
            508.2756652832031,
            383.44000244140625,
            530.8213500976562
          ],
          "text": "475 \nkVA \n"
        },
        {
          "bbox": [
            396.42999267578125,
            508.2756652832031,
            454.5090637207031,
            530.8213500976562
          ],
          "text": "Auto \n15kV\nA \n"
        },
        {
          "bbox": [
            467.3800048828125,
            508.2756652832031,
            489.9100036621094,
            530.8213500976562
          ],
          "text": "25 \nkVA \n"
        },
        {
          "bbox": [
            502.7799987792969,
            508.2756652832031,
            519.6699829101562,
            530.8213500976562
          ],
          "text": "50k\nVA \n"
        },
        {
          "bbox": [
            531.0999755859375,
            508.2756652832031,
            551.7576904296875,
            530.8213500976562
          ],
          "text": "100k\nVA \n"
        },
        {
          "bbox": [
            20.639999389648438,
            537.7955932617188,
            64.64328002929688,
            560.3413696289062
          ],
          "text": "TENDER \nQTY \n"
        },
        {
          "bbox": [
            77.42400360107422,
            537.7955932617188,
            538.6300048828125,
            548.8213500976562
          ],
          "text": "10 \n65 \n55 \n8 \n8 \n11 \n1 \n2 \n2 \n4 \n3 \n23 \n8 \n"
        },
        {
          "bbox": [
            20.639999389648438,
            567.2979736328125,
            546.1199951171875,
            580.5819702148438
          ],
          "text": "LOT No \n1 \n2 \n3 \n4 \n5 \n6 \n7 \n8 \n9 \n10 \n11 \n12 \n13 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            588.177978515625,
            75.02400207519531,
            601.4619750976562
          ],
          "text": " \n"
        },
        {
          "bbox": [
            297.7699890136719,
            601.9779663085938,
            300.7699890136719,
            767.0879516601562
          ],
          "text": " \n \n \n \n \n \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 14,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 15 of 52 \n \n \nREF SPECIFICATION NO. 18001 \nDISTRIBUTION TRANSFORMERS \n \n1.  \nSCOPE ....................................................................................................................... 17 \n2.  \nDETERMINATION OF RESPONSIVENESS ......................................................... 17 \n3.  \nPARTICULARS OF  ELECTRICAL SYSTEM ....................................................... 18 \n4.  \nPARTICULARS OF ENVIRONMENT .................................................................... 18 \n5.  \nSTANDARDS, UNITS AND LANGUAGE ............................................................. 19 \n6.  \nDESIGN ..................................................................................................................... 20 \n6.1  \nGeneral ....................................................................................................................... 20 \n6.2  \nWindings .................................................................................................................... 21 \n6.3   \nCores .......................................................................................................................... 22 \n6.4  \nTapping Switches ....................................................................................................... 22 \n6.5  \nBushings ..................................................................................................................... 23 \n6.6  \nTanks and Conservators ............................................................................................. 23 \n6.6.1  General ....................................................................................................................... 23 \n6.6.2  Tanks .......................................................................................................................... 24 \n6.6.3  Conservators .............................................................................................................. 24 \n6.7  \nAccessories and Fittings ............................................................................................ 25 \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 15 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.88801574707031,
            395.1099853515625,
            155.13197326660156
          ],
          "text": " \n \nREF SPECIFICATION NO. 18001 \nDISTRIBUTION TRANSFORMERS \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            179.64796447753906,
            520.4199829101562,
            192.9319610595703
          ],
          "text": "1.  \nSCOPE ....................................................................................................................... 17 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            217.44801330566406,
            520.4199829101562,
            230.7320098876953
          ],
          "text": "2.  \nDETERMINATION OF RESPONSIVENESS ......................................................... 17 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            255.2480010986328,
            520.4199829101562,
            268.5320129394531
          ],
          "text": "3.  \nPARTICULARS OF  ELECTRICAL SYSTEM ....................................................... 18 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            293.0780334472656,
            520.4199829101562,
            306.3620300292969
          ],
          "text": "4.  \nPARTICULARS OF ENVIRONMENT .................................................................... 18 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            330.8780212402344,
            520.4199829101562,
            344.1620178222656
          ],
          "text": "5.  \nSTANDARDS, UNITS AND LANGUAGE ............................................................. 19 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            368.6780090332031,
            520.4199829101562,
            381.9620056152344
          ],
          "text": "6.  \nDESIGN ..................................................................................................................... 20 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            406.4779968261719,
            520.4199829101562,
            419.7619934082031
          ],
          "text": "6.1  \nGeneral ....................................................................................................................... 20 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            444.27801513671875,
            520.4199829101562,
            457.56201171875
          ],
          "text": "6.2  \nWindings .................................................................................................................... 21 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            482.0979919433594,
            520.4199829101562,
            495.3819885253906
          ],
          "text": "6.3   \nCores .......................................................................................................................... 22 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            519.89794921875,
            520.4199829101562,
            533.1819458007812
          ],
          "text": "6.4  \nTapping Switches ....................................................................................................... 22 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            557.697998046875,
            520.4199829101562,
            570.9819946289062
          ],
          "text": "6.5  \nBushings ..................................................................................................................... 23 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            595.4979858398438,
            520.4199829101562,
            608.781982421875
          ],
          "text": "6.6  \nTanks and Conservators ............................................................................................. 23 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            633.3280029296875,
            520.4199829101562,
            646.6119995117188
          ],
          "text": "6.6.1  General ....................................................................................................................... 23 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            671.1279907226562,
            520.4199829101562,
            684.4119873046875
          ],
          "text": "6.6.2  Tanks .......................................................................................................................... 24 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            708.927978515625,
            520.4199829101562,
            722.2119750976562
          ],
          "text": "6.6.3  Conservators .............................................................................................................. 24 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            746.7239990234375,
            520.4199829101562,
            760.0079956054688
          ],
          "text": "6.7  \nAccessories and Fittings ............................................................................................ 25 \n"
        }
      ]
    },
    {
      "index": 15,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 16 of 52 \n7.0  \nINSULATING OIL .................................................................................................... 26 \n8.0  \nOVERLOADING CAPABILITY .............................................................................. 26 \n9.0  \nNOISE POLLUTION ................................................................................................ 26 \n10.  \nTESTS ........................................................................................................................ 27 \n11. \nPACKING AND TRANSPORT ................................................................................ 27 \n12.  \nDRAWINGS AND DIAGRAMS .............................................................................. 28 \n12.1 \nDrawings to be supplied with the Tender .................................................................. 28 \n12.2  Drawings to be supplied with the Contract ................................................................ 28 \n13.  \nMAXIMUM DIMENSIONS AND WEIGHTS REQUIRED ................................... 29 \n14.  \nEVALUATION OF LOSSES .................................................................................... 30 \n14.1  Guaranteed Output and Losses, Liquidated Damages ............................................... 30 \n14.2  Evaluation of Losses  (TO BE STATED).................................................................. 30 \n15.  \nDELIVERY PERIOD ................................................................................................ Error! Bookmark\n16.  \nTECHNICAL SCHEDULES ..................................................................................... 31 \n16.1  Preamble .................................................................................................................... 31 \n16.2  Definitions and Abbreviations ................................................................................... 34 \n \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 16 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            520.4199829101562,
            99.93196868896484
          ],
          "text": "7.0  \nINSULATING OIL .................................................................................................... 26 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            124.44801330566406,
            520.4199829101562,
            137.7320098876953
          ],
          "text": "8.0  \nOVERLOADING CAPABILITY .............................................................................. 26 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            162.2480010986328,
            520.4199829101562,
            175.53199768066406
          ],
          "text": "9.0  \nNOISE POLLUTION ................................................................................................ 26 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            200.04798889160156,
            520.4199829101562,
            213.3319854736328
          ],
          "text": "10.  \nTESTS ........................................................................................................................ 27 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            237.8479766845703,
            520.4199829101562,
            251.13197326660156
          ],
          "text": "11. \nPACKING AND TRANSPORT ................................................................................ 27 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            275.6780090332031,
            520.4199829101562,
            288.9620056152344
          ],
          "text": "12.  \nDRAWINGS AND DIAGRAMS .............................................................................. 28 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            313.4779968261719,
            520.4199829101562,
            326.7619934082031
          ],
          "text": "12.1 \nDrawings to be supplied with the Tender .................................................................. 28 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            351.27801513671875,
            520.4199829101562,
            364.56201171875
          ],
          "text": "12.2  Drawings to be supplied with the Contract ................................................................ 28 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            389.0780029296875,
            520.4199829101562,
            402.36199951171875
          ],
          "text": "13.  \nMAXIMUM DIMENSIONS AND WEIGHTS REQUIRED ................................... 29 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            426.8780212402344,
            520.4199829101562,
            440.1620178222656
          ],
          "text": "14.  \nEVALUATION OF LOSSES .................................................................................... 30 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            464.697998046875,
            520.4199829101562,
            477.98199462890625
          ],
          "text": "14.1  Guaranteed Output and Losses, Liquidated Damages ............................................... 30 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            502.4980163574219,
            520.4199829101562,
            515.781982421875
          ],
          "text": "14.2  Evaluation of Losses  (TO BE STATED).................................................................. 30 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            540.2979736328125,
            596.9520263671875,
            553.5819702148438
          ],
          "text": "15.  \nDELIVERY PERIOD ................................................................................................ Error! Bookmark\n"
        },
        {
          "bbox": [
            72.02400207519531,
            578.0979614257812,
            520.4199829101562,
            591.3819580078125
          ],
          "text": "16.  \nTECHNICAL SCHEDULES ..................................................................................... 31 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            615.89794921875,
            520.4199829101562,
            629.1819458007812
          ],
          "text": "16.1  Preamble .................................................................................................................... 31 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            653.7279663085938,
            520.4199829101562,
            763.8479614257812
          ],
          "text": "16.2  Definitions and Abbreviations ................................................................................... 34 \n \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 16,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 17 of 52 \n \n1. \nSCOPE \n \n \nThis specification covers the manufacture, testing,  supply and delivery of distribution \ntransformers and spares.  All transformers shall be capable of being loaded continuously \nat the full rating at ambient temperatures of 35 C, while exposed to direct tropical sun. \n \n \nThe Supplier shall state name, place and country of manufacture. The Supplier shall state \nwhether or not the transformers are produced under license, in which case licence \nholders name shall be stated. \n \n \nTenders shall include a complete statement of compliance with this specification. For \nevery clause in this specification the Tenderer shall state compliance or non-compliance \nand shall elaborate where appropriate. \n \n \nTenders shall use the words ‘comply’, ‘do not comply’  for this specification or in the \nclauses of an informative nature, ‘noted’. Where the words ‘do not comply’ are used the \nTenderer shall state whether modifications could be made and whether modifications \nwould be undertaken. The cost implications of such  modifications must be indicated in \nthe statement of  compliance as well as the pricing schedules. \n \n \nSpares as recommended by the supplier should be included in the scope of supply.   \n \n \nThe manufacture of the transformers should commence after inspection of the prototype \nby a REF representative. The supplier will meet all the costs associated with the \ninspection of the prototype transformers. \n \n2. \nDETERMINATION OF RESPONSIVENESS  \n \n \nPrior to the detailed evaluation of Tenders, the Authority will determine whether each \nTender is substantially responsive to the requirements of the Tender Document. \n \n2.1 \nFor the purpose of this clause, a substantially responsive Tender is one which will \nconform to all the terms, conditions and specifications of the Tender Document without \nmaterial deviations or reservations. A material deviation or reservation is one which \naffects in a substantial way the price, scope, quality completion timing or administration \nof the works undertaken by the Tenderer under the Contract, or which limits in a \nsubstantial way, inconsistent with the Tender Document, the Zimbabwe Electricity \nSupply Authority’s rights or the Tenderer’s obligations under the Contract and the \nrectification of which would affect unfairly the competitive position of other Tenders \nwho have presented substantially responsive Tenders at reasonable price. \n \n2.2  \nA Tender Determined to be substantially non-responsive will be rejected by the \nAuthority and may not subsequently be made responsive by the Tenderer by correction \nof the non-conformity. \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 17 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            75.02400207519531,
            99.93196868896484
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            112.68800354003906,
            525.860107421875,
            474.62200927734375
          ],
          "text": "1. \nSCOPE \n \n \nThis specification covers the manufacture, testing,  supply and delivery of distribution \ntransformers and spares.  All transformers shall be capable of being loaded continuously \nat the full rating at ambient temperatures of 35 C, while exposed to direct tropical sun. \n \n \nThe Supplier shall state name, place and country of manufacture. The Supplier shall state \nwhether or not the transformers are produced under license, in which case licence \nholders name shall be stated. \n \n \nTenders shall include a complete statement of compliance with this specification. For \nevery clause in this specification the Tenderer shall state compliance or non-compliance \nand shall elaborate where appropriate. \n \n \nTenders shall use the words ‘comply’, ‘do not comply’  for this specification or in the \nclauses of an informative nature, ‘noted’. Where the words ‘do not comply’ are used the \nTenderer shall state whether modifications could be made and whether modifications \nwould be undertaken. The cost implications of such  modifications must be indicated in \nthe statement of  compliance as well as the pricing schedules. \n \n \nSpares as recommended by the supplier should be included in the scope of supply.   \n \n \nThe manufacture of the transformers should commence after inspection of the prototype \nby a REF representative. The supplier will meet all the costs associated with the \ninspection of the prototype transformers. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            487.3780212402344,
            521.66015625,
            751.8479614257812
          ],
          "text": "2. \nDETERMINATION OF RESPONSIVENESS  \n \n \nPrior to the detailed evaluation of Tenders, the Authority will determine whether each \nTender is substantially responsive to the requirements of the Tender Document. \n \n2.1 \nFor the purpose of this clause, a substantially responsive Tender is one which will \nconform to all the terms, conditions and specifications of the Tender Document without \nmaterial deviations or reservations. A material deviation or reservation is one which \naffects in a substantial way the price, scope, quality completion timing or administration \nof the works undertaken by the Tenderer under the Contract, or which limits in a \nsubstantial way, inconsistent with the Tender Document, the Zimbabwe Electricity \nSupply Authority’s rights or the Tenderer’s obligations under the Contract and the \nrectification of which would affect unfairly the competitive position of other Tenders \nwho have presented substantially responsive Tenders at reasonable price. \n \n2.2  \nA Tender Determined to be substantially non-responsive will be rejected by the \nAuthority and may not subsequently be made responsive by the Tenderer by correction \nof the non-conformity. \n \n"
        }
      ]
    },
    {
      "index": 17,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 18 of 52 \n2.3 \nThe Zimbabwe Electricity Supply Authority may accept any non-material deviation or \nreservation provided that the acceptance thereof does not prejudice or affect the relative \nranking order of any Tender in the evaluation of Tenders. \n \n3.  \nPARTICULARS OF  ELECTRICAL SYSTEM  \n \n     \nUnless otherwise specified in Schedule of  Requirements,  it must be assumed that the \nsystem on which the equipment will operate is : \n \n \na) \nThree phase overhead-line construction and underground system. The \nmaximum earth fault factor on the network is 1.5. \n \n \nb) \nOperated at 50 Hz, with approximately sinusoidal wave form. \n \n \n \nc) \nThe highest system voltage does not normally exceed the nominal system \nvoltage by more than 10%.  The nominal system voltages are 33 kV and 11 kV. \n \n \nd) \nThe system frequency variation does not exceed plus or minus 2.5% from 50 Hz. \n \n \n \nDesigns should allow for these variations. \n \n \n4. \nPARTICULARS OF ENVIRONMENT  \n  \n \nThe transformers shall be capable of operating under the following environmental \nconditions. \n \n  \n \na) \nAmbient  temperatures: \n   \n \n \n(i) \nMaximum: \n \n40 °C \n \n \n(ii) \nMinimum:   \n \nminus 10 °C \n      \n \n(iii) \nMaximum daily average: 35 °C \n \n \nb) \nAltitude: \n \n \n \nMaximum altitude of 1 500 metres above sea level.  The design shall \nallow for reduced cooling effect due to high altitude.   \n \n \nc) \nThe transformers will be exposed to direct tropical sunlight. \n \n \nd) \nHumidity:  \n \n \n \nHumidity of 13mg per cubic metre absolute and 65% relative before \nstorms with vapour pressure of 17mmHg. \n \n \ne) \nTransformers will operate within the tropics and will be subjected to \nsudden ambient air temperature changes of  the order of 10 C per hour, \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 18 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            518.6600952148438,
            141.3319854736328
          ],
          "text": "2.3 \nThe Zimbabwe Electricity Supply Authority may accept any non-material deviation or \nreservation provided that the acceptance thereof does not prejudice or affect the relative \nranking order of any Tender in the evaluation of Tenders. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            154.0879669189453,
            525.8900756835938,
            404.7619934082031
          ],
          "text": "3.  \nPARTICULARS OF  ELECTRICAL SYSTEM  \n \n     \nUnless otherwise specified in Schedule of  Requirements,  it must be assumed that the \nsystem on which the equipment will operate is : \n \n \na) \nThree phase overhead-line construction and underground system. The \nmaximum earth fault factor on the network is 1.5. \n \n \nb) \nOperated at 50 Hz, with approximately sinusoidal wave form. \n \n \n \nc) \nThe highest system voltage does not normally exceed the nominal system \nvoltage by more than 10%.  The nominal system voltages are 33 kV and 11 kV. \n \n \nd) \nThe system frequency variation does not exceed plus or minus 2.5% from 50 Hz. \n \n \n \nDesigns should allow for these variations. \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            417.51800537109375,
            504.10003662109375,
            765.64794921875
          ],
          "text": "4. \nPARTICULARS OF ENVIRONMENT  \n  \n \nThe transformers shall be capable of operating under the following environmental \nconditions. \n \n  \n \na) \nAmbient  temperatures: \n   \n \n \n(i) \nMaximum: \n \n40 °C \n \n \n(ii) \nMinimum:   \n \nminus 10 °C \n      \n \n(iii) \nMaximum daily average: 35 °C \n \n \nb) \nAltitude: \n \n \n \nMaximum altitude of 1 500 metres above sea level.  The design shall \nallow for reduced cooling effect due to high altitude.   \n \n \nc) \nThe transformers will be exposed to direct tropical sunlight. \n \n \nd) \nHumidity:  \n \n \n \nHumidity of 13mg per cubic metre absolute and 65% relative before \nstorms with vapour pressure of 17mmHg. \n \n \ne) \nTransformers will operate within the tropics and will be subjected to \nsudden ambient air temperature changes of  the order of 10 C per hour, \n"
        }
      ]
    },
    {
      "index": 18,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 19 of 52 \noccurring at the onset of rain, but the barometric pressure at any given place does \nnot vary by more than approximately 10mm Mercury.   Frequent and severe \nlightning storms occur during summer months, with isoceraunic levels varying \nbetween 50 and 100 thunderstorm days per annum.  \n \n \n       \nIt is the manufacturers responsibility to make himself familiar with any \nother climatic and physical conditions pertaining in Zimbabwe and to allow for \nall conditions in his designs. \n \n \n     \nParticular attention should be paid in the design of all equipment to ensure that \nthere is no possibility of damage to working parts or insulation through the \ningress of dust, insects or vermin. \n \n \n \nAll orifices and air vents should be covered by  easily replaceable \nweather resisting, fine mesh wire where practicable. \n \n \n \n \n \n \n \n \n \n \n5. \nSTANDARDS, UNITS AND LANGUAGE \n  \n     \nExcept where modified by the Authority's Specifications, IEC Recommendations (IEC \n76) shall apply throughout or British Standards (BS) where they amplify the IEC 76. \n \n \nIn the case of conflict between the above stated Standards  \nand this Specification, the \nruling of this Specification will prevail. \n \n \nAll tenders, correspondence, description upon drawings, illustrations or instructions shall \nbe in unambiguous English Language. SI Units of measurements shall be used \nthroughout.  \n \n \n \n \nAll materials used in the manufacture of the transformers shall be new and of high \ncommercial quality. \n \n \nThe transformers shall be manufactured to high quality standards. \n \n \nType test certificates are to be submitted with the tender for each transformer rating and \nvoltage.  Type tests are either to be witnessed by or carried out by an internationally \nrecognised Test Institute, e.g. KEEMA and others.  A minimum requirement is that the \nTest Institute is unbiased with no direct connection to any private industries and that the \ninstitute is engaged in type tests on behalf of international clients. \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 19 of 52 \n"
        },
        {
          "bbox": [
            50.7599983215332,
            86.64796447753906,
            524.9002075195312,
            210.3319854736328
          ],
          "text": "occurring at the onset of rain, but the barometric pressure at any given place does \nnot vary by more than approximately 10mm Mercury.   Frequent and severe \nlightning storms occur during summer months, with isoceraunic levels varying \nbetween 50 and 100 thunderstorm days per annum.  \n \n \n       \nIt is the manufacturers responsibility to make himself familiar with any \nother climatic and physical conditions pertaining in Zimbabwe and to allow for \nall conditions in his designs. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            210.8479766845703,
            513.14013671875,
            431.1620178222656
          ],
          "text": " \n     \nParticular attention should be paid in the design of all equipment to ensure that \nthere is no possibility of damage to working parts or insulation through the \ningress of dust, insects or vermin. \n \n \n \nAll orifices and air vents should be covered by  easily replaceable \nweather resisting, fine mesh wire where practicable. \n \n \n \n \n \n \n \n \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            443.9179992675781,
            525.5,
            763.4879760742188
          ],
          "text": "5. \nSTANDARDS, UNITS AND LANGUAGE \n  \n     \nExcept where modified by the Authority's Specifications, IEC Recommendations (IEC \n76) shall apply throughout or British Standards (BS) where they amplify the IEC 76. \n \n \nIn the case of conflict between the above stated Standards  \nand this Specification, the \nruling of this Specification will prevail. \n \n \nAll tenders, correspondence, description upon drawings, illustrations or instructions shall \nbe in unambiguous English Language. SI Units of measurements shall be used \nthroughout.  \n \n \n \n \nAll materials used in the manufacture of the transformers shall be new and of high \ncommercial quality. \n \n \nThe transformers shall be manufactured to high quality standards. \n \n \nType test certificates are to be submitted with the tender for each transformer rating and \nvoltage.  Type tests are either to be witnessed by or carried out by an internationally \nrecognised Test Institute, e.g. KEEMA and others.  A minimum requirement is that the \nTest Institute is unbiased with no direct connection to any private industries and that the \ninstitute is engaged in type tests on behalf of international clients. \n \n \n"
        }
      ]
    },
    {
      "index": 19,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 20 of 52 \n \nThe transformers shall be sourced from manufacturers who have ISO 9001 Certification.  \nDocumentary evidence of the ISO 9001 Certification shall be provided with the bid.  \nManufacturers who cannot submit such certification are liable to be rejected. \n \n \n6. \nDESIGN  \n \n6.1 \nGeneral \n \n \na) \nThe Transformers shall be of the mineral oil immersed core type suitable \nfor outdoor use with ONAN cooling. \n \n \n \nThe transformers shall be capable of withstanding the maximum possible \nshort circuit current (Assuming an infinite busbar at the H.V) for a period of one \nsecond. \n \n \n \nb) \nAll transformers shall have a guaranteed life span of at least 25 years \noperating continuously under full rated power at an ambient temperature of 35 \nC on any tapping under the following conditions: \n \n \n \ni) \nWith the voltage of the untapped winding at normal, \nwithout the need to derate the transformer at the extreme tap positions \nand without oil temperature rise exceeding 55 C at  the top of the \ntransformer. The winding temperature rise shall not exceed 60 C. \n \n \n \nii) \nWith voltage applied up to 10% in excess of the rated \ntapping voltages and without injurious overheating. \n \n \n(c) \nTransformers shall be connected in accordance with BS 171: three phase \ntransformers to Vector Group reference Dynll. \n \n \n(d) \nThe L.V neutrals shall be brought out of the tank to a readily accessible terminal \nand shall not be earthed inside the tank, unless otherwise specified in the enquiry. \n \n \n(e)  \nTransformers on a particular contract with similar kVA rating, voltage ratios and \nconnections shall be suitable for parallel operation on all relevant taps under \nwhich conditions they should share the load in  proportion to their ratings subject \nto the tolerances on impedance laid down in IEC 76 or BS 171. \n \n \n(f)  \nIf it is required to parallel any transformer with existing transformers then \nfull details of the existing  transformers will be provided when tenders are \nplaced. \n   \n \n(g)  \nLow impedance transformers are preferred, a maximum of 5% being \nenvisaged on any size with no plus  tolerance. \n \n \n(h) \nAn oil gauge shall be provided for non-sealed transformers. \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 20 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            527.1800537109375,
            155.13197326660156
          ],
          "text": " \nThe transformers shall be sourced from manufacturers who have ISO 9001 Certification.  \nDocumentary evidence of the ISO 9001 Certification shall be provided with the bid.  \nManufacturers who cannot submit such certification are liable to be rejected. \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            167.8880157470703,
            159.97999572753906,
            197.7320098876953
          ],
          "text": "6. \nDESIGN  \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            210.4879913330078,
            526.489990234375,
            767.447998046875
          ],
          "text": "6.1 \nGeneral \n \n \na) \nThe Transformers shall be of the mineral oil immersed core type suitable \nfor outdoor use with ONAN cooling. \n \n \n \nThe transformers shall be capable of withstanding the maximum possible \nshort circuit current (Assuming an infinite busbar at the H.V) for a period of one \nsecond. \n \n \n \nb) \nAll transformers shall have a guaranteed life span of at least 25 years \noperating continuously under full rated power at an ambient temperature of 35 \nC on any tapping under the following conditions: \n \n \n \ni) \nWith the voltage of the untapped winding at normal, \nwithout the need to derate the transformer at the extreme tap positions \nand without oil temperature rise exceeding 55 C at  the top of the \ntransformer. The winding temperature rise shall not exceed 60 C. \n \n \n \nii) \nWith voltage applied up to 10% in excess of the rated \ntapping voltages and without injurious overheating. \n \n \n(c) \nTransformers shall be connected in accordance with BS 171: three phase \ntransformers to Vector Group reference Dynll. \n \n \n(d) \nThe L.V neutrals shall be brought out of the tank to a readily accessible terminal \nand shall not be earthed inside the tank, unless otherwise specified in the enquiry. \n \n \n(e)  \nTransformers on a particular contract with similar kVA rating, voltage ratios and \nconnections shall be suitable for parallel operation on all relevant taps under \nwhich conditions they should share the load in  proportion to their ratings subject \nto the tolerances on impedance laid down in IEC 76 or BS 171. \n \n \n(f)  \nIf it is required to parallel any transformer with existing transformers then \nfull details of the existing  transformers will be provided when tenders are \nplaced. \n   \n \n(g)  \nLow impedance transformers are preferred, a maximum of 5% being \nenvisaged on any size with no plus  tolerance. \n \n \n(h) \nAn oil gauge shall be provided for non-sealed transformers. \n"
        }
      ]
    },
    {
      "index": 20,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 21 of 52 \n \n \n \nThe following details shall apply to sealed designs: \n \n \n \ni) \nTransformers sealed by welding are not acceptable, and  \nwill be rejected by the Authority. \n \n  \n \nii) \nAny holes or plugs used to facilitate vacuum/pressure \ntesting, leak testing or oil filling  of the transformer shall finally be \nsealed. \n \n \n \niii) \nThe expansion space for the oil shall not be  less than 25 \npercent of the volume of the oil at 20 degrees Celsius, for transformers \nwith conservators and transformers using the tank for expansion, and \nshall be nitrogen filled. The transformer shall be sealed at atmospheric \npressure. \n \n \n \niv) \nTransformers using the expandable ribs for expansion \nshall be totally filled with oil and  sealed at atmospheric pressure. \n       \n \n \nv) \nPressure valves, pressure/vacuum gauges and non-return \nvalves shall not be fitted. \n \n \n \n \nvi) \nDrain plugs shall be fitted to transformer tanks up to and \nincluding 315 kVA, whilst drain valves shall be fitted to transformer \ntanks above 315 kVA  \n \n   \n \n \nvii) \nEarth studs are required at both the H.V and L.V ends of transformer. \n \n \n6.2 \nWindings \n \n \n(a)  \nTappings shall be provided in the H.V windings, preferably in the electrical \ncentre of the windings, to permit variation of the number of H.V turns without \nany variation in the kVA rating. The variations shall be effected by means of a \nmanually operated tapping switch to be provided in accordance with clause 6(4). \n \n \n(b) \nAll windings and terminations shall be fully insulated and those for \nservice above 1 000 volts shall be designed for impulse voltage tests. \n \n \n \nDesigns shall be such that electrical stresses are as uniform as possible \nthroughout the windings under impulse conditions. \n \n \n(c) \nWindings shall be vacuum impregnated and insulating materials shall not \nbe liable to soften, shrink, become brittle, carbonise, deteriorate, or collapse in \nany way during service. \n \n(e) L.V windings of Aluminium sheet are not acceptable. Transformers with such windings \nwill be rejected. \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 21 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            519.0999755859375,
            472.5820007324219
          ],
          "text": " \n \n \nThe following details shall apply to sealed designs: \n \n \n \ni) \nTransformers sealed by welding are not acceptable, and  \nwill be rejected by the Authority. \n \n  \n \nii) \nAny holes or plugs used to facilitate vacuum/pressure \ntesting, leak testing or oil filling  of the transformer shall finally be \nsealed. \n \n \n \niii) \nThe expansion space for the oil shall not be  less than 25 \npercent of the volume of the oil at 20 degrees Celsius, for transformers \nwith conservators and transformers using the tank for expansion, and \nshall be nitrogen filled. The transformer shall be sealed at atmospheric \npressure. \n \n \n \niv) \nTransformers using the expandable ribs for expansion \nshall be totally filled with oil and  sealed at atmospheric pressure. \n       \n \n \nv) \nPressure valves, pressure/vacuum gauges and non-return \nvalves shall not be fitted. \n \n \n \n \nvi) \nDrain plugs shall be fitted to transformer tanks up to and \nincluding 315 kVA, whilst drain valves shall be fitted to transformer \ntanks above 315 kVA  \n \n   \n \n \nvii) \nEarth studs are required at both the H.V and L.V ends of transformer. \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            485.3380126953125,
            524.81005859375,
            722.2119750976562
          ],
          "text": "6.2 \nWindings \n \n \n(a)  \nTappings shall be provided in the H.V windings, preferably in the electrical \ncentre of the windings, to permit variation of the number of H.V turns without \nany variation in the kVA rating. The variations shall be effected by means of a \nmanually operated tapping switch to be provided in accordance with clause 6(4). \n \n \n(b) \nAll windings and terminations shall be fully insulated and those for \nservice above 1 000 volts shall be designed for impulse voltage tests. \n \n \n \nDesigns shall be such that electrical stresses are as uniform as possible \nthroughout the windings under impulse conditions. \n \n \n(c) \nWindings shall be vacuum impregnated and insulating materials shall not \nbe liable to soften, shrink, become brittle, carbonise, deteriorate, or collapse in \nany way during service. \n \n"
        },
        {
          "bbox": [
            79.10399627685547,
            722.4400024414062,
            509.42413330078125,
            735.8919677734375
          ],
          "text": "(e) L.V windings of Aluminium sheet are not acceptable. Transformers with such windings \n"
        },
        {
          "bbox": [
            72.02400207519531,
            736.4039916992188,
            174.5,
            763.4879760742188
          ],
          "text": "will be rejected. \n \n"
        }
      ]
    },
    {
      "index": 21,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 22 of 52 \n6.3 \n Cores \n \n \n(a) \nThe magnetic circuit shall be earthed to the core clamping structure, at one point \nonly, and the core assembly to the tank cover. Where transformers are not sealed, \nreadily accessible removable bolted links shall be employed for the earthing \nconnections. \n \n \n(b) \nThe general construction of the cores, framework and the clamping \narrangements shall be robust and such that they will be capable of withstanding \ncompletely any stresses which may occur due to handling, transport or service.  \nAll cores and yokes shall be terminated and clamped by means of a suitable \nframework.  Suitable means shall be provided for lifting the cores from the tanks. \n \n \n(c) \nIt shall not be possible for the core to move relative to the tank during \nhandling or transport. Designs which  contravene this requirement will be \nrejected. \n \n \n(d) \nParticular attention shall be paid to maintaining low core loss consistent \nwith sound design. \n \n6.4 \nTapping Switches \n \n \n(a) \nTransformers shall be provided with approved off-circuit type tap \nchanging \nequipment. A fully insulated off circuit externally manually  \noperated ganged tapping switch shall be separately capable of withstanding the \nspecified impulse voltage when connected to the transformer windings. \n \n \n(b) \nClearly visible tap position indication shall be provided.  The tapping \nswitch shall be operated by means of an external handle which can be positively \nlocated and locked in each operating position. \n \n \n \nThe switch shall be mechanically robust and provided with a device \nbetween the handle and the switch to permit operation without strain in the event \nof imperfect alignment between switch and handle. The switch operating shaft \nshall be fully insulated as between tank and switch and shall be provided with a \nsuitable oil and vacuum tight gland where it passes through the tank. \n \n \n(c) \nThe use of wood shall be avoided wherever possible and all the supports and \nterminal boards shall be completely unaffected by hot oil and shall be non-\nmoisture absorbent. \n \n \n(d) \nHigh grade insulating materials shall be used in the construction of \ntapping switches which shall be designed with special attention to the elimination \nof points where tracking is likely to occur. \n \n \n(e) \nTapping switches shall be mounted on supports made of suitable high \nstrength insulating material and shall be provided with self-aligning spring \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 22 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.88801574707031,
            525.7000122070312,
            365.1620178222656
          ],
          "text": "6.3 \n Cores \n \n \n(a) \nThe magnetic circuit shall be earthed to the core clamping structure, at one point \nonly, and the core assembly to the tank cover. Where transformers are not sealed, \nreadily accessible removable bolted links shall be employed for the earthing \nconnections. \n \n \n(b) \nThe general construction of the cores, framework and the clamping \narrangements shall be robust and such that they will be capable of withstanding \ncompletely any stresses which may occur due to handling, transport or service.  \nAll cores and yokes shall be terminated and clamped by means of a suitable \nframework.  Suitable means shall be provided for lifting the cores from the tanks. \n \n \n(c) \nIt shall not be possible for the core to move relative to the tank during \nhandling or transport. Designs which  contravene this requirement will be \nrejected. \n \n \n(d) \nParticular attention shall be paid to maintaining low core loss consistent \nwith sound design. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            377.9179992675781,
            526.4600830078125,
            752.68798828125
          ],
          "text": "6.4 \nTapping Switches \n \n \n(a) \nTransformers shall be provided with approved off-circuit type tap \nchanging \nequipment. A fully insulated off circuit externally manually  \noperated ganged tapping switch shall be separately capable of withstanding the \nspecified impulse voltage when connected to the transformer windings. \n \n \n(b) \nClearly visible tap position indication shall be provided.  The tapping \nswitch shall be operated by means of an external handle which can be positively \nlocated and locked in each operating position. \n \n \n \nThe switch shall be mechanically robust and provided with a device \nbetween the handle and the switch to permit operation without strain in the event \nof imperfect alignment between switch and handle. The switch operating shaft \nshall be fully insulated as between tank and switch and shall be provided with a \nsuitable oil and vacuum tight gland where it passes through the tank. \n \n \n(c) \nThe use of wood shall be avoided wherever possible and all the supports and \nterminal boards shall be completely unaffected by hot oil and shall be non-\nmoisture absorbent. \n \n \n(d) \nHigh grade insulating materials shall be used in the construction of \ntapping switches which shall be designed with special attention to the elimination \nof points where tracking is likely to occur. \n \n \n(e) \nTapping switches shall be mounted on supports made of suitable high \nstrength insulating material and shall be provided with self-aligning spring \n"
        }
      ]
    },
    {
      "index": 22,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 23 of 52 \nloaded wiping contacts capable of maintaining good electrical contact without \nthe need for periodic maintenance. \n \n \n \nAll clearance between tapping switch contacts and leads shall be \nindicated on drawings submitted at the time of tendering and such clearances \nshall be sufficient to prevent tracking or flashover in the event of carbon or \nsludge deposits forming on leakage paths. \n \n \n(f) \nThe tappings to be provided on the H.V winding shall be as follows:-\nMinus 5%: Minus 2.5%: 0%(Normal): Plus 2.5%:  Plus 5% \n \n6.5 \nBushings  \n \n \n(a) \nAll line terminals and neutral connections where specified, shall be \nbrought out to porcelain outdoor type terminal bushings.  The bushings shall be \nthe outdoor type.  \n \n \n(b) \nArcing horns with equal double gaps shall be fitted on all transformer \nbushings above 660 volt. The total gap length (for two gaps) shall be set at 60 to \n70mm for 11kV \nand 140 to 150mm for 33kV nominal voltage. \n      \n \n(c) \nThe bushings shall have minimum Creepage distances of 670mm and \n250mm for nominal voltages of 33 and 11kV respectively. \n \n6.6 \nTanks and Conservators  \n \n6.6.1 General \n \n \ni) \nDrain valves may be either screwed or flanged whilst conservator isolator \nvalves shall be flanged. Drain valves shall be complete with captive plugs which \nshall be either of non-ferrous metal or galvanised. \n \n \nii) \nAll internal steel surfaces or tanks and conservators shall  be shot blasted \nand cleaned, and a coat of protecting compound, unaffected by  hot oil, should be \napplied. \n \n \niii) \nAll external surfaces and parts made of steel are to be thoroughly shot \nblasted and cleaned, after which two coats of priming paint, preferably of zinc \nchromate, one intermediate coat, and one coat of finishing paint are to be applied. \nThe colour of the finishing coat shall be medium Sea Grey, Colour No. 637 to BS \n381C. \n \n \n \niv) \nTransformers on which the paints are found to flake off or deteriorate \nwithin the guarantee period shall be suitably cleaned and repainted free of charge \nby the supplier. Suppliers providing such transformers will not in the future be \ngiven the opportunity to offer transformers to REF.  \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 23 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            510.380126953125,
            237.9319610595703
          ],
          "text": "loaded wiping contacts capable of maintaining good electrical contact without \nthe need for periodic maintenance. \n \n \n \nAll clearance between tapping switch contacts and leads shall be \nindicated on drawings submitted at the time of tendering and such clearances \nshall be sufficient to prevent tracking or flashover in the event of carbon or \nsludge deposits forming on leakage paths. \n \n \n(f) \nThe tappings to be provided on the H.V winding shall be as follows:-\nMinus 5%: Minus 2.5%: 0%(Normal): Plus 2.5%:  Plus 5% \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            250.68800354003906,
            520.5801391601562,
            432.36199951171875
          ],
          "text": "6.5 \nBushings  \n \n \n(a) \nAll line terminals and neutral connections where specified, shall be \nbrought out to porcelain outdoor type terminal bushings.  The bushings shall be \nthe outdoor type.  \n \n \n(b) \nArcing horns with equal double gaps shall be fitted on all transformer \nbushings above 660 volt. The total gap length (for two gaps) shall be set at 60 to \n70mm for 11kV \nand 140 to 150mm for 33kV nominal voltage. \n      \n \n(c) \nThe bushings shall have minimum Creepage distances of 670mm and \n250mm for nominal voltages of 33 and 11kV respectively. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            445.1180114746094,
            240.0500030517578,
            474.98199462890625
          ],
          "text": "6.6 \nTanks and Conservators  \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            487.7380065917969,
            527.5701293945312,
            765.8880004882812
          ],
          "text": "6.6.1 General \n \n \ni) \nDrain valves may be either screwed or flanged whilst conservator isolator \nvalves shall be flanged. Drain valves shall be complete with captive plugs which \nshall be either of non-ferrous metal or galvanised. \n \n \nii) \nAll internal steel surfaces or tanks and conservators shall  be shot blasted \nand cleaned, and a coat of protecting compound, unaffected by  hot oil, should be \napplied. \n \n \niii) \nAll external surfaces and parts made of steel are to be thoroughly shot \nblasted and cleaned, after which two coats of priming paint, preferably of zinc \nchromate, one intermediate coat, and one coat of finishing paint are to be applied. \nThe colour of the finishing coat shall be medium Sea Grey, Colour No. 637 to BS \n381C. \n \n \n \niv) \nTransformers on which the paints are found to flake off or deteriorate \nwithin the guarantee period shall be suitably cleaned and repainted free of charge \nby the supplier. Suppliers providing such transformers will not in the future be \ngiven the opportunity to offer transformers to REF.  \n"
        }
      ]
    },
    {
      "index": 23,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 24 of 52 \n \n6.6.2 Tanks \n \n \ni) \nEach transformer shall be housed in a tank of welded steel  \nplate \nconstruction suitably stiffened where necessary but with a flat base. \n \n \n \n \nWheels as rollers shall be provided for transformers rated  \nabove 500 \nkVA. Transformers rated equal to or less than 500 kVA shall not be provided \nwith wheels as rollers.  \n \n \nii) \nThe lifting lugs shall be suitable for lifting the transformer bodily by \nmeans of a hoist or crane when it is completely assembled and ready for service. \n \n \niii) \nAll transformers up to and including 315 kVA rating  shall be provided \nwith four fixing lugs on the base drilled with 16mm holes for bolting to a \nplatform. \n \n \n \nThe fixing holes shall project beyond the ends of the tank and be placed \nto provide the most practicable stable arrangement. \n \n6.6.3 Conservators \n \n \ni) \nConservators, shall be dimensioned such that oil expansion may occur \nover the working range of temperature from no load with the transformer cold \nand at minus 10 degrees Celsius  \nambient air temperature to full load at plus \n40 degrees Celsius ambient air temperature while the sump pipe remains covered \nand the oil level is visible or indicated. \n \n \nii) \nDrain plugs shall preferably incorporate approved sampling facilities, and \nshall be mounted at the lowest part of the conservator tank and so designed that \nthe sampling device can be readily cleared in the event of its being blocked by an \naccumulation of sludge etc., without the necessity of having to dismantle the \ndevice completely. \n \n \niii)  \nOil level gauges on conservator tanks shall be of the refracting plate glass \nor other approved type, marked with the level at 20 degrees Celsius at no-load \nand capable of indicating the level of oil over the specified working range. \n \n \niv) \nWhere dehydrating breathers are specified they shall be of the Silica gel \ntype which give indication of moisture absorption by change in colour of the \ncharge. \n \n \n \nAn inspection window shall be provided and mounted in a position \nconvenient for inspection. The breather is to incorporate an oil seal to prevent \ncontact with the external air when breathing is not taking place. The breather is to \nbe fitted on the LV end of the transformer. \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 24 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            75.02400207519531,
            99.93196868896484
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            112.68800354003906,
            521.260009765625,
            377.1620178222656
          ],
          "text": "6.6.2 Tanks \n \n \ni) \nEach transformer shall be housed in a tank of welded steel  \nplate \nconstruction suitably stiffened where necessary but with a flat base. \n \n \n \n \nWheels as rollers shall be provided for transformers rated  \nabove 500 \nkVA. Transformers rated equal to or less than 500 kVA shall not be provided \nwith wheels as rollers.  \n \n \nii) \nThe lifting lugs shall be suitable for lifting the transformer bodily by \nmeans of a hoist or crane when it is completely assembled and ready for service. \n \n \niii) \nAll transformers up to and including 315 kVA rating  shall be provided \nwith four fixing lugs on the base drilled with 16mm holes for bolting to a \nplatform. \n \n \n \nThe fixing holes shall project beyond the ends of the tank and be placed \nto provide the most practicable stable arrangement. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            389.9179992675781,
            526.5802001953125,
            764.68798828125
          ],
          "text": "6.6.3 Conservators \n \n \ni) \nConservators, shall be dimensioned such that oil expansion may occur \nover the working range of temperature from no load with the transformer cold \nand at minus 10 degrees Celsius  \nambient air temperature to full load at plus \n40 degrees Celsius ambient air temperature while the sump pipe remains covered \nand the oil level is visible or indicated. \n \n \nii) \nDrain plugs shall preferably incorporate approved sampling facilities, and \nshall be mounted at the lowest part of the conservator tank and so designed that \nthe sampling device can be readily cleared in the event of its being blocked by an \naccumulation of sludge etc., without the necessity of having to dismantle the \ndevice completely. \n \n \niii)  \nOil level gauges on conservator tanks shall be of the refracting plate glass \nor other approved type, marked with the level at 20 degrees Celsius at no-load \nand capable of indicating the level of oil over the specified working range. \n \n \niv) \nWhere dehydrating breathers are specified they shall be of the Silica gel \ntype which give indication of moisture absorption by change in colour of the \ncharge. \n \n \n \nAn inspection window shall be provided and mounted in a position \nconvenient for inspection. The breather is to incorporate an oil seal to prevent \ncontact with the external air when breathing is not taking place. The breather is to \nbe fitted on the LV end of the transformer. \n \n"
        }
      ]
    },
    {
      "index": 24,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 25 of 52 \n6.7 \nAccessories and Fittings  \n \n \n(a) \nAll transformers shall be provided with accessories and fittings in \naccordance with the tables below, unless otherwise specified in the enquiry: \n \n \n \nIn the following tables ‘Y’ means yes (To be provided) \n \n \n \n \n‘N’ means no  (Not to be provided) \n \nACCESSORIES  AND  FITTINGS\nFOR\n11/0.4  and  33/0.4  kVA  DISTRIBUTION  TRANSFORMERS.\nTransformer Nominal Ratings\n11kV  Primary Voltage\n33kV  Primary voltage\nUpto but\n100 kVA\n500 kVA\n \n500 kVA\nexcluding\nbut\nand\nupto but \nand \nTRANSFORMER TANK FITTINGS\n100 kVA\nexcluding\nabove\nexcluding\nabove\nFree\nSealed\n500 kVA\n 500 kVA\nBreathing\n1 Conservator\nN\nN\nY\nY\nY\nY\n2 Drain valve with captive sealing plug\nY\nN\nY\nY\nY\nY\n3 Lifting lugs\nY\nY\nY\nY\nY\nY\n4 Thermometer Pocket\nN\nN\nN\nY\nN\nY\n5 Rating and Diagram plate\nY\nY\nY\nY\nY\nY\n6 Hanger irons\nY\nY\nN\nN\nN\nN\n7 Platform mounting lugs\nY\nY\nY\nN\nY\nN\n8 Earthing Terminal\nY\nY\nY\nY\nY\nY\n9 Lightning arrestor brackets\nN\nN\nN\nY\nN\nY\n10 Dial type thermometer\nN\nN\nN\nY\nN\nY\n11 Jacking pads\nN\nN\n(Required only when the mass of the complete\ntransformer is 1 000 kg or more.)\n12 Plain breather\nY\nN\nN\nN\nN\n13 Oil gauge\nY\nY\nOn Concervator\n14 Mounting plate for Item 6 to be suitable\nN\nN\nN\nY\nN\nY\nfor mounting marshalling box Item 17)\n15 Lashing down facilities\nY\nY\nY\nY\nY\nY\n16 Marshalling box for Item 10 of Tank fitting \nand Item 7 of Conservator fittings\nConservator fittings\n1 Drain plugs\nN/A\nY\nY\nY\nY\n2 Sampler\nN/A\nY\nY\nY\nY\n3 Separate filling hole with caps\nN/A\nY\nY\nY\nY\n4 Dehydrating breather\nN/A\nAbove 100 kVA\nY\nY\nY\n5 Plain breather\nN/A\n100 kVA\nN\nN\nN\n6 Oil gauge\nN/A\nY\nY\nY\nY\n7 Gas and oil actuated relay\nN/A\nN\nY\nN\nY\n8 Conservator isolating valve\nN/A\nN\nY\nN\nY\n \n \n(b) \nRating and diagram plates shall be of engraved brass or other approved non-corroding \nmaterial and shall be placed on the L.V side of the transformer. \n \n(c) \nWhere a thermometer pocket is provided, it shall be of a thin walled metal mounted in \nthe tank cover.  The pocket shall project 25mm outside of the tank and shall be threaded \nalong the whole projecting portion with a 19mm B.S.P. male thread, a screwed cap shall \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 25 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.88801574707031,
            500.0199890136719,
            199.53199768066406
          ],
          "text": "6.7 \nAccessories and Fittings  \n \n \n(a) \nAll transformers shall be provided with accessories and fittings in \naccordance with the tables below, unless otherwise specified in the enquiry: \n \n \n \nIn the following tables ‘Y’ means yes (To be provided) \n \n \n \n \n‘N’ means no  (Not to be provided) \n \n"
        },
        {
          "bbox": [
            250.44317626953125,
            201.73414611816406,
            449.83660888671875,
            215.46054077148438
          ],
          "text": "ACCESSORIES  AND  FITTINGS\n"
        },
        {
          "bbox": [
            164.3208465576172,
            217.9009246826172,
            535.2694702148438,
            264.5476989746094
          ],
          "text": "FOR\n11/0.4  and  33/0.4  kVA  DISTRIBUTION  TRANSFORMERS.\nTransformer Nominal Ratings\n"
        },
        {
          "bbox": [
            113.61221313476562,
            269.8747253417969,
            572.722900390625,
            455.0081481933594
          ],
          "text": "11kV  Primary Voltage\n33kV  Primary voltage\nUpto but\n100 kVA\n500 kVA\n \n500 kVA\nexcluding\nbut\nand\nupto but \nand \nTRANSFORMER TANK FITTINGS\n100 kVA\nexcluding\nabove\nexcluding\nabove\nFree\nSealed\n500 kVA\n 500 kVA\nBreathing\n1 Conservator\nN\nN\nY\nY\nY\nY\n2 Drain valve with captive sealing plug\nY\nN\nY\nY\nY\nY\n3 Lifting lugs\nY\nY\nY\nY\nY\nY\n4 Thermometer Pocket\nN\nN\nN\nY\nN\nY\n5 Rating and Diagram plate\nY\nY\nY\nY\nY\nY\n6 Hanger irons\nY\nY\nN\nN\nN\nN\n7 Platform mounting lugs\nY\nY\nY\nN\nY\nN\n8 Earthing Terminal\nY\nY\nY\nY\nY\nY\n9 Lightning arrestor brackets\nN\nN\nN\nY\nN\nY\n10 Dial type thermometer\nN\nN\nN\nY\nN\nY\n11 Jacking pads\nN\nN\n(Required only when the mass of the complete\n"
        },
        {
          "bbox": [
            113.61221313476562,
            456.6321105957031,
            552.8574829101562,
            542.8960571289062
          ],
          "text": "transformer is 1 000 kg or more.)\n12 Plain breather\nY\nN\nN\nN\nN\n13 Oil gauge\nY\nY\nOn Concervator\n14 Mounting plate for Item 6 to be suitable\nN\nN\nN\nY\nN\nY\nfor mounting marshalling box Item 17)\n15 Lashing down facilities\nY\nY\nY\nY\nY\nY\n16 Marshalling box for Item 10 of Tank fitting \nand Item 7 of Conservator fittings\n"
        },
        {
          "bbox": [
            72.02400207519531,
            555.484375,
            552.8574829101562,
            763.7279663085938
          ],
          "text": "Conservator fittings\n1 Drain plugs\nN/A\nY\nY\nY\nY\n2 Sampler\nN/A\nY\nY\nY\nY\n3 Separate filling hole with caps\nN/A\nY\nY\nY\nY\n4 Dehydrating breather\nN/A\nAbove 100 kVA\nY\nY\nY\n5 Plain breather\nN/A\n100 kVA\nN\nN\nN\n6 Oil gauge\nN/A\nY\nY\nY\nY\n7 Gas and oil actuated relay\nN/A\nN\nY\nN\nY\n8 Conservator isolating valve\nN/A\nN\nY\nN\nY\n \n \n(b) \nRating and diagram plates shall be of engraved brass or other approved non-corroding \nmaterial and shall be placed on the L.V side of the transformer. \n \n(c) \nWhere a thermometer pocket is provided, it shall be of a thin walled metal mounted in \nthe tank cover.  The pocket shall project 25mm outside of the tank and shall be threaded \nalong the whole projecting portion with a 19mm B.S.P. male thread, a screwed cap shall \n"
        }
      ]
    },
    {
      "index": 25,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 26 of 52 \nbe provided to cover the pocket when not in use. The pocket shall have internal \ndimensions of not less than 19mm diameter and 115mm length. \n   \n(d) \nHanger irons, where specified, shall be suitable for  \nsuspending the transformer from a \n102mm x 51mm Mild  Steel Channel cross-arm, bolted to the vertical legs of an 'H' pole. \nA suitable stop shall be provided at the base of the tank to enable the transformer to be \nsuspended vertically, and rest against a similar 102 mm x 51mm Channel provided on the \n'H' pole at a lower level for this purpose. The hanger irons shall be drilled for an M16 \nbolt to enable them to be bolted to the vertical web of the cross-arm and thereby prevent \nany lateral movement of the transformer. \n \n \nThe hanger irons shall be mounted on the LV side of the transformer tank. \n \n7.0 \nINSULATING OIL  \n \n \nThe transformers shall be fitted with low viscosity \nmineral  \ninsulating oil which \ncomplies in every respect with the  \nprovisions of BS 148. \n \n8.0 \nOVERLOADING CAPABILITY \n \n \nThe transformer shall be capable of overload at 35 C ambient temperature without \nreduction in the anticipated working life of the transformer, as shown in the curve below. \n         \n     \nTRANSFORMER OVERLOAD CAPABILITY\n100\n105\n110\n115\n120\n125\n130\n135\n140\n145\n150\n2\n4\n6\n8\n10\n12\n14\n16\n18\n20\n22\n24\nHours\nPercentage Load\n% load\n \n \n \nThe maximum load at other periods is assumed to be 70% of the  \ntransformer rating \nfor the above transformer overload  capability curve.  \n \n9.0 \nNOISE POLLUTION \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 26 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            528.5001220703125,
            265.5320129394531
          ],
          "text": "be provided to cover the pocket when not in use. The pocket shall have internal \ndimensions of not less than 19mm diameter and 115mm length. \n   \n(d) \nHanger irons, where specified, shall be suitable for  \nsuspending the transformer from a \n102mm x 51mm Mild  Steel Channel cross-arm, bolted to the vertical legs of an 'H' pole. \nA suitable stop shall be provided at the base of the tank to enable the transformer to be \nsuspended vertically, and rest against a similar 102 mm x 51mm Channel provided on the \n'H' pole at a lower level for this purpose. The hanger irons shall be drilled for an M16 \nbolt to enable them to be bolted to the vertical web of the cross-arm and thereby prevent \nany lateral movement of the transformer. \n \n \nThe hanger irons shall be mounted on the LV side of the transformer tank. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            278.3180236816406,
            527.5,
            349.56201171875
          ],
          "text": "7.0 \nINSULATING OIL  \n \n \nThe transformers shall be fitted with low viscosity \nmineral  \ninsulating oil which \ncomplies in every respect with the  \nprovisions of BS 148. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            362.3179931640625,
            525.5800170898438,
            434.4020080566406
          ],
          "text": "8.0 \nOVERLOADING CAPABILITY \n \n \nThe transformer shall be capable of overload at 35 C ambient temperature without \nreduction in the anticipated working life of the transformer, as shown in the curve below. \n         \n"
        },
        {
          "bbox": [
            108.0199966430664,
            652.16796875,
            122.53998565673828,
            665.4519653320312
          ],
          "text": "     \n"
        },
        {
          "bbox": [
            158.3653564453125,
            447.9339294433594,
            386.2607727050781,
            461.3359375
          ],
          "text": "TRANSFORMER OVERLOAD CAPABILITY\n"
        },
        {
          "bbox": [
            153.85008239746094,
            611.792724609375,
            167.43841552734375,
            621.0233764648438
          ],
          "text": "100\n"
        },
        {
          "bbox": [
            153.85008239746094,
            597.54150390625,
            167.43841552734375,
            606.7721557617188
          ],
          "text": "105\n"
        },
        {
          "bbox": [
            153.85008239746094,
            583.290283203125,
            167.43841552734375,
            592.5209350585938
          ],
          "text": "110\n"
        },
        {
          "bbox": [
            153.85008239746094,
            569.0390014648438,
            167.43841552734375,
            578.2696533203125
          ],
          "text": "115\n"
        },
        {
          "bbox": [
            153.85008239746094,
            554.790771484375,
            167.43841552734375,
            564.0214233398438
          ],
          "text": "120\n"
        },
        {
          "bbox": [
            153.85008239746094,
            540.5595092773438,
            167.43841552734375,
            549.7901611328125
          ],
          "text": "125\n"
        },
        {
          "bbox": [
            153.85008239746094,
            526.3082885742188,
            167.43841552734375,
            535.5389404296875
          ],
          "text": "130\n"
        },
        {
          "bbox": [
            153.85008239746094,
            512.0570678710938,
            167.43841552734375,
            521.2877197265625
          ],
          "text": "135\n"
        },
        {
          "bbox": [
            153.85008239746094,
            497.80584716796875,
            167.43841552734375,
            507.0364685058594
          ],
          "text": "140\n"
        },
        {
          "bbox": [
            153.85008239746094,
            483.5545959472656,
            167.43841552734375,
            492.78521728515625
          ],
          "text": "145\n"
        },
        {
          "bbox": [
            153.85008239746094,
            469.3033752441406,
            167.43841552734375,
            478.53399658203125
          ],
          "text": "150\n"
        },
        {
          "bbox": [
            168.85948181152344,
            622.1688232421875,
            178.09498596191406,
            626.771728515625
          ],
          "text": "2\n"
        },
        {
          "bbox": [
            184.6050262451172,
            622.1688232421875,
            193.8405303955078,
            626.771728515625
          ],
          "text": "4\n"
        },
        {
          "bbox": [
            201.09844970703125,
            622.1688232421875,
            210.33395385742188,
            626.771728515625
          ],
          "text": "6\n"
        },
        {
          "bbox": [
            216.8419952392578,
            622.1688232421875,
            226.07749938964844,
            626.771728515625
          ],
          "text": "8\n"
        },
        {
          "bbox": [
            232.5885467529297,
            622.181640625,
            241.8240509033203,
            631.273681640625
          ],
          "text": "10\n"
        },
        {
          "bbox": [
            248.3350830078125,
            622.181640625,
            257.5705871582031,
            631.273681640625
          ],
          "text": "12\n"
        },
        {
          "bbox": [
            264.83050537109375,
            622.181640625,
            274.0660095214844,
            631.273681640625
          ],
          "text": "14\n"
        },
        {
          "bbox": [
            280.59698486328125,
            622.181640625,
            289.8324890136719,
            631.273681640625
          ],
          "text": "16\n"
        },
        {
          "bbox": [
            296.34356689453125,
            622.181640625,
            305.5790710449219,
            631.273681640625
          ],
          "text": "18\n"
        },
        {
          "bbox": [
            312.080078125,
            622.181640625,
            321.3155822753906,
            631.273681640625
          ],
          "text": "20\n"
        },
        {
          "bbox": [
            328.5755615234375,
            622.181640625,
            337.81103515625,
            631.273681640625
          ],
          "text": "22\n"
        },
        {
          "bbox": [
            344.32208251953125,
            622.181640625,
            353.5575866699219,
            631.273681640625
          ],
          "text": "24\n"
        },
        {
          "bbox": [
            249.09120178222656,
            637.2872924804688,
            272.6656188964844,
            646.5179443359375
          ],
          "text": "Hours\n"
        },
        {
          "bbox": [
            138.11927795410156,
            515.5855102539062,
            147.3547821044922,
            580.2865600585938
          ],
          "text": "Percentage Load\n"
        },
        {
          "bbox": [
            390.0711669921875,
            540.5595092773438,
            414.3043518066406,
            549.7901611328125
          ],
          "text": "% load\n"
        },
        {
          "bbox": [
            72.02400207519531,
            652.16796875,
            519.4599609375,
            717.6519775390625
          ],
          "text": " \n \n \nThe maximum load at other periods is assumed to be 70% of the  \ntransformer rating \nfor the above transformer overload  capability curve.  \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            730.407958984375,
            223.3699951171875,
            760.2479858398438
          ],
          "text": "9.0 \nNOISE POLLUTION \n \n"
        }
      ]
    },
    {
      "index": 26,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 27 of 52 \n \nThe maximum values for the noise levels of the various distribution transformers shall be \nas given in the table below: \n           \n            \nTRANSFORMER RATING kVA\nMAXIMUM POLLUTION dB(A)\nLess than or equal to 50kVA\n48\nBetween 50 and 315kVA\n55\nBetween 315 and 500kVA\n56\nBetween 500 and 800kVA\n57\nBetween 800 and 1000kVA\n58\nBetween 1000 and 1600kVA\n60\nAbove 1600 kVA\n61\n \n          \n \nTransformers with Noise Pollution levels higher than that given above will be rejected \nby the Authority. \n \n10. \nTESTS  \n \n \nElectrical tests are to be carried out according to IEC 76.  Routine covering test \ncertificates shall be submitted immediately after completion of tests  in the factory, for \neach and every identical group of transformers. \n \n \nThe following tests shall be carried out in addition to the routine tests: \n \n \n(a) \nAs a type test, a temperature rise test on each different rating of transformer. \n \n \n(b) \nAs a special test, an impulse voltage withstand test \nincluding chopped \nwaves on each different rating of  transformer. \n \n \nNOTE: \nIf tests to (a) and (b) above have been carried out \n \nsatisfactorily on designs identical in all essential details,  tests (a) and (b) \nmay be waived on the production of  acceptable certified type test certificates. \n \n11. \nPACKING AND TRANSPORT  \n \n \nTransformers shall be transported to destination with their tanks full of oil up to the \nservice level. \n \n \nBushings and any accessories or fittings likely to be damaged shall be protected \nadequately against damage in transit. \n \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 27 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            526.7001342773438,
            127.5320053100586
          ],
          "text": " \nThe maximum values for the noise levels of the various distribution transformers shall be \nas given in the table below: \n           \n"
        },
        {
          "bbox": [
            108.0199966430664,
            234.2480010986328,
            142.4600067138672,
            247.53199768066406
          ],
          "text": "            \n"
        },
        {
          "bbox": [
            72.02400207519531,
            129.83653259277344,
            525.3920288085938,
            299.7619934082031
          ],
          "text": "TRANSFORMER RATING kVA\nMAXIMUM POLLUTION dB(A)\nLess than or equal to 50kVA\n48\nBetween 50 and 315kVA\n55\nBetween 315 and 500kVA\n56\nBetween 500 and 800kVA\n57\nBetween 800 and 1000kVA\n58\nBetween 1000 and 1600kVA\n60\nAbove 1600 kVA\n61\n \n          \n \nTransformers with Noise Pollution levels higher than that given above will be rejected \nby the Authority. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            312.5180358886719,
            521.6199951171875,
            549.3819580078125
          ],
          "text": "10. \nTESTS  \n \n \nElectrical tests are to be carried out according to IEC 76.  Routine covering test \ncertificates shall be submitted immediately after completion of tests  in the factory, for \neach and every identical group of transformers. \n \n \nThe following tests shall be carried out in addition to the routine tests: \n \n \n(a) \nAs a type test, a temperature rise test on each different rating of transformer. \n \n \n(b) \nAs a special test, an impulse voltage withstand test \nincluding chopped \nwaves on each different rating of  transformer. \n \n \nNOTE: \nIf tests to (a) and (b) above have been carried out \n \nsatisfactorily on designs identical in all essential details,  tests (a) and (b) \nmay be waived on the production of  acceptable certified type test certificates. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            562.137939453125,
            498.6200866699219,
            757.6079711914062
          ],
          "text": "11. \nPACKING AND TRANSPORT  \n \n \nTransformers shall be transported to destination with their tanks full of oil up to the \nservice level. \n \n \nBushings and any accessories or fittings likely to be damaged shall be protected \nadequately against damage in transit. \n \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 27,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 28 of 52 \n \n \n \n \n12. \nDRAWINGS AND DIAGRAMS  \n \n12.1 \nDrawings to be supplied with the Tender  \n \n \nThe following drawings shall be supplied with any tender.  \n \n \n(a) \nGeneral arrangement drawing of each rating of  transformer offered showing : \n \n \n \n(i) \nAll dimensions on height, width, depth, etc., minimum clearance (phase \nto phase and phase to earth) on H.V. and  L.V. bushings including \nclearance H.V. to L.V. \n \n \n \n(ii) \nWeights of oil, core/winding assembly and transformer fully erected. \n \n \n \n(iii) \nPositions and identification in a separate legend of all fittings with type \nnumbers. \n \n \n \n(iv) \nSize and position of all fixing holes. \n \n \n(b) \nDetailed dimensioned drawings of tapping switch illustrating type of material, \nclearances, between tapping points and to earth and method of operation. \n \n \n(c) \nDetailed dimensioned drawings of bushings, silica gel or plain oil seal type \nbreather, and conservator. \n \n   \n \nNOTE: \nWhere sealed transformers are offered, a cross arrangement \ndrawing shall be submitted with the tender showing, in particular, details \nof the tank construction and internal tank finish and the depth of the \nexpansion space above the oil. \n \n12.2 \nDrawings to be supplied with the Contract  \n \n \n(a) \nLatest issues of the drawing listed under Clause 12.1 shall be supplied under the \ncontract. If no modifications are applicable to the drawings supplied with the \ntender, this shall be confirmed in writing under the contract and further drawings \nneed not be supplied. \n \n \n(b)  \nRating and diagram plate shall include the following information: \n \n \n \nI) \nManufacturer \n \n \nii) \nSize in kVA \n \n \niii) \nVector group \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 28 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            75.02400207519531,
            141.3319854736328
          ],
          "text": " \n \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            154.0879669189453,
            280.010009765625,
            183.9319610595703
          ],
          "text": "12. \nDRAWINGS AND DIAGRAMS  \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            196.68800354003906,
            522.0501098632812,
            585.3819580078125
          ],
          "text": "12.1 \nDrawings to be supplied with the Tender  \n \n \nThe following drawings shall be supplied with any tender.  \n \n \n(a) \nGeneral arrangement drawing of each rating of  transformer offered showing : \n \n \n \n(i) \nAll dimensions on height, width, depth, etc., minimum clearance (phase \nto phase and phase to earth) on H.V. and  L.V. bushings including \nclearance H.V. to L.V. \n \n \n \n(ii) \nWeights of oil, core/winding assembly and transformer fully erected. \n \n \n \n(iii) \nPositions and identification in a separate legend of all fittings with type \nnumbers. \n \n \n \n(iv) \nSize and position of all fixing holes. \n \n \n(b) \nDetailed dimensioned drawings of tapping switch illustrating type of material, \nclearances, between tapping points and to earth and method of operation. \n \n \n(c) \nDetailed dimensioned drawings of bushings, silica gel or plain oil seal type \nbreather, and conservator. \n \n   \n \nNOTE: \nWhere sealed transformers are offered, a cross arrangement \ndrawing shall be submitted with the tender showing, in particular, details \nof the tank construction and internal tank finish and the depth of the \nexpansion space above the oil. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            598.137939453125,
            523.0599975585938,
            765.8880004882812
          ],
          "text": "12.2 \nDrawings to be supplied with the Contract  \n \n \n(a) \nLatest issues of the drawing listed under Clause 12.1 shall be supplied under the \ncontract. If no modifications are applicable to the drawings supplied with the \ntender, this shall be confirmed in writing under the contract and further drawings \nneed not be supplied. \n \n \n(b)  \nRating and diagram plate shall include the following information: \n \n \n \nI) \nManufacturer \n \n \nii) \nSize in kVA \n \n \niii) \nVector group \n"
        }
      ]
    },
    {
      "index": 28,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 29 of 52 \n \n \niv) \nVoltage rating \n \n \nv) \nYear of manufacture \n \n \nvi) \nTotal weight \n \n \nvii) \nFull load loss  \n \n \nviii) \nNo load loss \n \n \nix) \nVolume of oil in litres \n \n \nx) \nREF Tender number \n \n \nxi) \nREF order number \n \n \nxii) \nPercentage impedance \n \n \nxiii) \nVoltage table at various tap positions \n \n13. \nMAXIMUM DIMENSIONS AND WEIGHTS REQUIRED \n \n \nThe dimensions of the transformers are as shown on the drawings above. \n \n \nThe dimensions referred to above shall mean the following: \n \n \ni) \nMaximum height shall be denoted by (h1) \n \nii) \nMaximum width shall be denoted by (a1) \n \niii) \nMaximum depth shall be denoted by (b) \n \n \nThe maximum dimensions in mm and weights in kg shall be as indicated in the table \nbelow.  Any transformer  whose dimensions and weights exceed the stated values will be \nrejected. \n \nRATING \nkVA \nRATIO \nHEIGHT (h1) DEPTH (b) \nWIDTH (a1) \nWEIGHT \n(kg) \n10 single ph. \n11/0.4 \n900 \n770 \n782 \n240 \n10 \n11/0.4 \n850 \n780 \n800 \n245 \n15 \n11/0.4 \n929 \n782 \n930 \n360 \n25 \n11/0.4 \n929 \n782 \n930 \n360 \n50 \n11/0.4 \n1500 \n910 \n950 \n445 \n100 \n11/0.4 \n1650 \n1130 \n1050 \n673 \n15 \n33/0.4 \n1415 \n670 \n1500 \n500 \n25 \n33/0.4 \n1415 \n670 \n1500 \n550 \n50 \n33/0.4 \n2025 \n1230 \n1280 \n1180 \n100 \n33/0.4 \n2070 \n1490 \n1380 \n1250 \n \n \n \n \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 29 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            355.6300048828125,
            237.9319610595703
          ],
          "text": " \n \niv) \nVoltage rating \n \n \nv) \nYear of manufacture \n \n \nvi) \nTotal weight \n \n \nvii) \nFull load loss  \n \n \nviii) \nNo load loss \n \n \nix) \nVolume of oil in litres \n \n \nx) \nREF Tender number \n \n \nxi) \nREF order number \n \n \nxii) \nPercentage impedance \n \n \nxiii) \nVoltage table at various tap positions \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            250.68800354003906,
            525.7400512695312,
            474.50201416015625
          ],
          "text": "13. \nMAXIMUM DIMENSIONS AND WEIGHTS REQUIRED \n \n \nThe dimensions of the transformers are as shown on the drawings above. \n \n \nThe dimensions referred to above shall mean the following: \n \n \ni) \nMaximum height shall be denoted by (h1) \n \nii) \nMaximum width shall be denoted by (a1) \n \niii) \nMaximum depth shall be denoted by (b) \n \n \nThe maximum dimensions in mm and weights in kg shall be as indicated in the table \nbelow.  Any transformer  whose dimensions and weights exceed the stated values will be \nrejected. \n \nRATING \nkVA \n"
        },
        {
          "bbox": [
            72.02400207519531,
            447.39801025390625,
            506.3800048828125,
            758.68798828125
          ],
          "text": "RATIO \nHEIGHT (h1) DEPTH (b) \nWIDTH (a1) \nWEIGHT \n(kg) \n10 single ph. \n11/0.4 \n900 \n770 \n782 \n240 \n10 \n11/0.4 \n850 \n780 \n800 \n245 \n15 \n11/0.4 \n929 \n782 \n930 \n360 \n25 \n11/0.4 \n929 \n782 \n930 \n360 \n50 \n11/0.4 \n1500 \n910 \n950 \n445 \n100 \n11/0.4 \n1650 \n1130 \n1050 \n673 \n15 \n33/0.4 \n1415 \n670 \n1500 \n500 \n25 \n33/0.4 \n1415 \n670 \n1500 \n550 \n50 \n33/0.4 \n2025 \n1230 \n1280 \n1180 \n100 \n33/0.4 \n2070 \n1490 \n1380 \n1250 \n \n \n \n \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 29,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 30 of 52 \n \n \n \n \n14. \nEVALUATION OF LOSSES \n \n14.1 \nGuaranteed Output and Losses, Liquidated Damages \n \n \nFailure to meet the guaranteed outputs and losses with be dealt with as follows: \n \n \nTransformer Output \n \n \nIf the guaranteed continuous output at rated voltage of any transformer has to be \nreduced below the guaranteed value in order to maintain the temperature rises of any \npart of the transformer within the guaranteed limits, liquidated damages shall be paid at \nthe rate of ZWD (TO BE SPECIFIED) per kVA. \n \nTransformer Losses \n \n \nIf the total transformer losses of any transformer, as determined by these, without any \ntolerances, at rated voltage, frequency and 100% rated kVA (on principal tapping) \nexceed the guaranteed total losses, the excess in losses shall be capitalised at the rates \nstated in Sub-Clause 14.2 below and the resulting amount shall be paid as liquidated \ndamages. \n \n \nThe payment on account of failure of one or more transformer to meet the guaranteed \noutput and guaranteed losses shall be applied individually, as the case may be, and shall \ntherefore be understood to be cumulative. \n \n \nRejection Limits \n \n \nShould any transformer fail to meet the guaranteed output by more than 5% (five per \ncent) or the total losses should exceed the total guaranteed losses by more that 1/5 (one \nfifth), and should the Contractor fail within a reasonable time to modify the transformer \nin order to increase the output and/or reduce the losses sufficiently, the Purchaser shall \nhave the option to reject the transformer. \n \n14.2 \nEvaluation of Losses  (TO BE STATED) \n \n \nTransformer losses will be evaluated based on the following figures: \n \n \nLoad losses:   ZWD (TO BE STATED)/kW \n \nNo load losses:  ZWD (TO BE STATED)/kW \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 30 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            75.02400207519531,
            141.3319854736328
          ],
          "text": " \n \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            154.0879669189453,
            260.45001220703125,
            183.9319610595703
          ],
          "text": "14. \nEVALUATION OF LOSSES \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            196.68800354003906,
            523.8880004882812,
            626.781982421875
          ],
          "text": "14.1 \nGuaranteed Output and Losses, Liquidated Damages \n \n \nFailure to meet the guaranteed outputs and losses with be dealt with as follows: \n \n \nTransformer Output \n \n \nIf the guaranteed continuous output at rated voltage of any transformer has to be \nreduced below the guaranteed value in order to maintain the temperature rises of any \npart of the transformer within the guaranteed limits, liquidated damages shall be paid at \nthe rate of ZWD (TO BE SPECIFIED) per kVA. \n \nTransformer Losses \n \n \nIf the total transformer losses of any transformer, as determined by these, without any \ntolerances, at rated voltage, frequency and 100% rated kVA (on principal tapping) \nexceed the guaranteed total losses, the excess in losses shall be capitalised at the rates \nstated in Sub-Clause 14.2 below and the resulting amount shall be paid as liquidated \ndamages. \n \n \nThe payment on account of failure of one or more transformer to meet the guaranteed \noutput and guaranteed losses shall be applied individually, as the case may be, and shall \ntherefore be understood to be cumulative. \n \n \nRejection Limits \n \n \nShould any transformer fail to meet the guaranteed output by more than 5% (five per \ncent) or the total losses should exceed the total guaranteed losses by more that 1/5 (one \nfifth), and should the Contractor fail within a reasonable time to modify the transformer \nin order to increase the output and/or reduce the losses sufficiently, the Purchaser shall \nhave the option to reject the transformer. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            639.5679931640625,
            444.5799865722656,
            765.8880004882812
          ],
          "text": "14.2 \nEvaluation of Losses  (TO BE STATED) \n \n \nTransformer losses will be evaluated based on the following figures: \n \n \nLoad losses:   ZWD (TO BE STATED)/kW \n \nNo load losses:  ZWD (TO BE STATED)/kW \n \n \n \n"
        }
      ]
    },
    {
      "index": 30,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 31 of 52 \n \n \n \n \n15. \nTECHNICAL GUARANTEE SCHEDULES \n \n15.1 \nPreamble \n \n15.1.1 \nThe Technical Schedules shall be filled in and completed by the Bidder, and \nsubmitted with the Bid (see example below) \n \nDISTRIBUTION \nTRANSFORMERs \nREF Requirement  \nCla\nuse \nDescription \nUnit \nRequired \nValues \nRequired \nValues \nRequired \nValues \nRequired \nValues \n1 \nName of \nManufacturer \n  \n  \n  \n  \n  \n2 \nCountry of \nManufacturer \n  \n  \n  \n  \n  \n3 \nContinuous \nMaximum \nRating \n(C.M.R.) \nkVA \n25 \n50 \n50 \n25 \n4 \nNormal \nvoltage \nbetween \nphase at no \nload \n  \n  \n  \n  \n  \n  \n(a)  H.V \nVolts \n33000 \n33000 \n11000 \n11000 \n  \n(b)  LV \nVolts \n400 \n400 \n400 \n400 \n  \nNo of phases \nper \ntransformer \n  \n3 \n  \n3 \n3 \n5 \nTappings \n  \n  \n  \n  \n  \n  \n(a)  Plus \n% \n5 \n5 \n5 \n5 \n  \n(b)  Minus \n% \n5 \n5 \n5 \n5 \n6 \nPerformance \nData at Sea \n  \n  \n  \n  \n  \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 31 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            75.02400207519531,
            141.3319854736328
          ],
          "text": " \n \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            154.0879669189453,
            339.07000732421875,
            183.9319610595703
          ],
          "text": "15. \nTECHNICAL GUARANTEE SCHEDULES \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            196.68800354003906,
            480.9680480957031,
            300.4820251464844
          ],
          "text": "15.1 \nPreamble \n \n15.1.1 \nThe Technical Schedules shall be filled in and completed by the Bidder, and \nsubmitted with the Bid (see example below) \n \nDISTRIBUTION \nTRANSFORMERs \nREF Requirement  \n"
        },
        {
          "bbox": [
            75.26399993896484,
            333.39801025390625,
            93.26399993896484,
            346.6820068359375
          ],
          "text": "Cla\n"
        },
        {
          "bbox": [
            75.86399841308594,
            333.39801025390625,
            292.45404052734375,
            360.48199462890625
          ],
          "text": "use \nDescription \nUnit \nRequired \n"
        },
        {
          "bbox": [
            248.2100067138672,
            347.197998046875,
            285.8900146484375,
            360.48199462890625
          ],
          "text": "Values \n"
        },
        {
          "bbox": [
            316.75,
            333.39801025390625,
            367.71405029296875,
            346.6820068359375
          ],
          "text": "Required \n"
        },
        {
          "bbox": [
            323.4700012207031,
            347.197998046875,
            361.1499938964844,
            360.48199462890625
          ],
          "text": "Values \n"
        },
        {
          "bbox": [
            391.989990234375,
            333.39801025390625,
            442.95404052734375,
            346.6820068359375
          ],
          "text": "Required \n"
        },
        {
          "bbox": [
            398.7099914550781,
            347.197998046875,
            436.4200134277344,
            360.48199462890625
          ],
          "text": "Values \n"
        },
        {
          "bbox": [
            467.260009765625,
            333.39801025390625,
            518.2240600585938,
            346.6820068359375
          ],
          "text": "Required \n"
        },
        {
          "bbox": [
            473.9800109863281,
            347.197998046875,
            511.6600036621094,
            360.48199462890625
          ],
          "text": "Values \n"
        },
        {
          "bbox": [
            81.26399993896484,
            375.75799560546875,
            175.5800018310547,
            402.8420104980469
          ],
          "text": "1 \nName of \nManufacturer \n"
        },
        {
          "bbox": [
            187.85000610351562,
            375.9980163574219,
            193.85000610351562,
            389.2820129394531
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            264.04998779296875,
            417.39801025390625,
            420.54998779296875,
            430.9219970703125
          ],
          "text": "  \n  \n  \n"
        },
        {
          "bbox": [
            489.82000732421875,
            396.75799560546875,
            495.82000732421875,
            410.0419921875
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            81.26399993896484,
            431.6780090332031,
            175.5800018310547,
            458.7619934082031
          ],
          "text": "2 \nCountry of \nManufacturer \n"
        },
        {
          "bbox": [
            187.85000610351562,
            431.9179992675781,
            193.85000610351562,
            445.2019958496094
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            81.26399993896484,
            473.4580078125,
            495.82000732421875,
            542.4219360351562
          ],
          "text": "  \n  \n  \n  \n3 \nContinuous \nMaximum \nRating \n(C.M.R.) \n"
        },
        {
          "bbox": [
            193.49000549316406,
            487.7380065917969,
            219.77000427246094,
            501.0220031738281
          ],
          "text": "kVA \n"
        },
        {
          "bbox": [
            259.489990234375,
            508.3780212402344,
            500.260009765625,
            521.6619873046875
          ],
          "text": "25 \n50 \n50 \n25 \n"
        },
        {
          "bbox": [
            81.26399993896484,
            543.41796875,
            164.15602111816406,
            611.9019775390625
          ],
          "text": "4 \nNormal \nvoltage \nbetween \nphase at no \nload \n"
        },
        {
          "bbox": [
            203.69000244140625,
            543.41796875,
            209.69000244140625,
            556.7019653320312
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            82.7040023803711,
            598.6179809570312,
            509.260009765625,
            683.3319702148438
          ],
          "text": "  \n  \n  \n  \n  \n(a)  H.V \nVolts \n33000 \n33000 \n11000 \n11000 \n  \n(b)  LV \nVolts \n400 \n400 \n400 \n400 \n  \nNo of phases \nper \ntransformer \n"
        },
        {
          "bbox": [
            203.69000244140625,
            642.447998046875,
            209.69000244140625,
            655.7319946289062
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            262.489990234375,
            670.0479736328125,
            271.489990234375,
            683.3319702148438
          ],
          "text": "3 \n"
        },
        {
          "bbox": [
            339.30999755859375,
            642.447998046875,
            345.30999755859375,
            655.7319946289062
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            81.26399993896484,
            670.0479736328125,
            497.260009765625,
            755.68798828125
          ],
          "text": "3 \n3 \n5 \nTappings \n  \n  \n  \n  \n  \n  \n(a)  Plus \n% \n5 \n5 \n5 \n5 \n  \n(b)  Minus \n% \n5 \n5 \n5 \n5 \n6 \nPerformance \nData at Sea \n"
        },
        {
          "bbox": [
            203.69000244140625,
            728.6079711914062,
            209.69000244140625,
            741.8919677734375
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            264.04998779296875,
            742.4039916992188,
            495.82000732421875,
            755.68798828125
          ],
          "text": "  \n  \n  \n  \n"
        }
      ]
    },
    {
      "index": 31,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 32 of 52 \nLevel \ncorrected at \nsea 75% \n  \n(a)   No load \nloss at \nprimary \nvoltage \nWatts \n350 \n198 \n330 \n130 \n  \n(b) No load \nLoss At 10% \nPrimary \nOvervoltage \nWatts \n522 \n240 \n450 \n158 \n  \n(c )  Load loss \nat C.M.R \nWatts \n1800 \n620 \n1800 \n580 \n  \n(d)   \nImpedance \nC.M.R and \nnormal ratio \n% \n≤5 \n≤5 \n≤5 \n≤5 \n  \n(e)    \nMaximum \ntemperature \nrise at C.M.R \n  \n  \n  \n  \n  \n  \n         i )  Top \noil by \nthermometer \nDeg. \nCels \n55 \n55 \n55 \n55 \n  \n         ii)   \nAverage \nresistance per \nwinding \nDeg. \nCels \n60 \n60 \n60 \n60 \n  \n         iii)  Hot \nSpot \ncorresponding \nto (ii) \nDeg. \nCels \n60 \n60 \n60 \n60 \n7 \nType of \ninsulation in \nwindings \n  \n  \n  \n  \n  \n  \n(a)   H.V \n  \nEnamel \nInsulation \nEnamel \nInsulation \nEnamel \nInsulation \nEnamel \nInsulation \n  \n(b)   LV \n  \nPaper \nPaper \nPaper \nPaper \n8 \nLightning \nimpulse \ninsulation \nlevel \n  \n  \n  \n  \n  \n  \n(a)   H.V \nwinding \nkV pk \n170 \n170 \n170 \n170 \n  \n(b)   L.V \nwinding \nkV pk \nN/A \nN/A \nN/A \nN/A \n  \n(c)   Tap \nchange \n  \n  \n  \n  \n  \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 32 of 52 \n"
        },
        {
          "bbox": [
            82.7040023803711,
            86.64796447753906,
            170.80401611328125,
            183.2119903564453
          ],
          "text": "Level \ncorrected at \nsea 75% \n  \n(a)   No load \nloss at \nprimary \nvoltage \n"
        },
        {
          "bbox": [
            191.2100067138672,
            128.52796936035156,
            222.1699981689453,
            141.8119659423828
          ],
          "text": "Watts \n"
        },
        {
          "bbox": [
            82.7040023803711,
            169.92799377441406,
            503.260009765625,
            238.89198303222656
          ],
          "text": "350 \n198 \n330 \n130 \n  \n(b) No load \nLoss At 10% \nPrimary \nOvervoltage \n"
        },
        {
          "bbox": [
            191.2100067138672,
            184.2079620361328,
            222.1699981689453,
            197.49195861816406
          ],
          "text": "Watts \n"
        },
        {
          "bbox": [
            82.7040023803711,
            225.6079864501953,
            503.260009765625,
            266.9720153808594
          ],
          "text": "522 \n240 \n450 \n158 \n  \n(c )  Load loss \nat C.M.R \n"
        },
        {
          "bbox": [
            191.2100067138672,
            239.8880157470703,
            222.1699981689453,
            253.17201232910156
          ],
          "text": "Watts \n"
        },
        {
          "bbox": [
            82.7040023803711,
            253.68800354003906,
            503.260009765625,
            322.6819763183594
          ],
          "text": "1800 \n620 \n1800 \n580 \n  \n(d)   \nImpedance \nC.M.R and \nnormal ratio \n"
        },
        {
          "bbox": [
            200.2100067138672,
            267.9980163574219,
            213.1699981689453,
            281.2820129394531
          ],
          "text": "% \n"
        },
        {
          "bbox": [
            82.7040023803711,
            309.3979797363281,
            500.6199951171875,
            378.48199462890625
          ],
          "text": "≤5 \n≤5 \n≤5 \n≤5 \n  \n(e)    \nMaximum \ntemperature \nrise at C.M.R \n"
        },
        {
          "bbox": [
            203.69000244140625,
            323.7980041503906,
            209.69000244140625,
            337.0820007324219
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            82.7040023803711,
            365.197998046875,
            495.82000732421875,
            420.36199951171875
          ],
          "text": "  \n  \n  \n  \n  \n         i )  Top \noil by \nthermometer \n"
        },
        {
          "bbox": [
            193.72999572753906,
            379.4779968261719,
            219.63800048828125,
            392.7619934082031
          ],
          "text": "Deg. \n"
        },
        {
          "bbox": [
            194.4499969482422,
            393.27801513671875,
            218.80999755859375,
            406.56201171875
          ],
          "text": "Cels \n"
        },
        {
          "bbox": [
            82.7040023803711,
            407.0780029296875,
            500.260009765625,
            476.06201171875
          ],
          "text": "55 \n55 \n55 \n55 \n  \n         ii)   \nAverage \nresistance per \nwinding \n"
        },
        {
          "bbox": [
            193.72999572753906,
            421.3580017089844,
            219.63800048828125,
            434.6419982910156
          ],
          "text": "Deg. \n"
        },
        {
          "bbox": [
            194.4499969482422,
            435.15802001953125,
            218.80999755859375,
            448.4420166015625
          ],
          "text": "Cels \n"
        },
        {
          "bbox": [
            82.7040023803711,
            462.77801513671875,
            500.260009765625,
            531.7420043945312
          ],
          "text": "60 \n60 \n60 \n60 \n  \n         iii)  Hot \nSpot \ncorresponding \nto (ii) \n"
        },
        {
          "bbox": [
            193.72999572753906,
            477.0580139160156,
            219.63800048828125,
            490.3420104980469
          ],
          "text": "Deg. \n"
        },
        {
          "bbox": [
            194.4499969482422,
            490.8580017089844,
            218.80999755859375,
            504.1419982910156
          ],
          "text": "Cels \n"
        },
        {
          "bbox": [
            81.26399993896484,
            518.4580078125,
            500.260009765625,
            573.6220092773438
          ],
          "text": "60 \n60 \n60 \n60 \n7 \nType of \ninsulation in \nwindings \n"
        },
        {
          "bbox": [
            203.69000244140625,
            532.7379760742188,
            209.69000244140625,
            546.02197265625
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            82.7040023803711,
            560.3380126953125,
            495.82000732421875,
            601.7019653320312
          ],
          "text": "  \n  \n  \n  \n  \n(a)   H.V \n  \nEnamel \nInsulation \n"
        },
        {
          "bbox": [
            316.75,
            574.6179809570312,
            367.75,
            601.7019653320312
          ],
          "text": "Enamel \nInsulation \n"
        },
        {
          "bbox": [
            391.989990234375,
            574.6179809570312,
            443.0199890136719,
            601.7019653320312
          ],
          "text": "Enamel \nInsulation \n"
        },
        {
          "bbox": [
            81.26399993896484,
            574.6179809570312,
            518.260009765625,
            672.1719360351562
          ],
          "text": "Enamel \nInsulation \n  \n(b)   LV \n  \nPaper \nPaper \nPaper \nPaper \n8 \nLightning \nimpulse \ninsulation \nlevel \n"
        },
        {
          "bbox": [
            203.69000244140625,
            617.4580078125,
            209.69000244140625,
            630.7420043945312
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            82.7040023803711,
            658.887939453125,
            495.82000732421875,
            700.251953125
          ],
          "text": "  \n  \n  \n  \n  \n(a)   H.V \nwinding \n"
        },
        {
          "bbox": [
            190.3699951171875,
            673.16796875,
            223.00999450683594,
            686.4519653320312
          ],
          "text": "kV pk \n"
        },
        {
          "bbox": [
            82.7040023803711,
            686.9679565429688,
            503.260009765625,
            728.4519653320312
          ],
          "text": "170 \n170 \n170 \n170 \n  \n(b)   L.V \nwinding \n"
        },
        {
          "bbox": [
            190.3699951171875,
            701.3679809570312,
            223.00999450683594,
            714.6519775390625
          ],
          "text": "kV pk \n"
        },
        {
          "bbox": [
            82.7040023803711,
            715.16796875,
            504.5799865722656,
            756.5279541015625
          ],
          "text": "N/A \nN/A \nN/A \nN/A \n  \n(c)   Tap \nchange \n"
        },
        {
          "bbox": [
            203.69000244140625,
            729.447998046875,
            209.69000244140625,
            742.7319946289062
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            264.04998779296875,
            743.2439575195312,
            495.82000732421875,
            756.5279541015625
          ],
          "text": "  \n  \n  \n  \n"
        }
      ]
    },
    {
      "index": 32,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 33 of 52 \nequipment \nand \nconnections \n  \n         i)   To \nearth \nkV pk \n170 \n170 \n170 \n170 \n  \n         ii)   \nBetween \ncontact \nkV pk \n1/4 of 170kV \npk \n1/4 of 170kV \npk \n1/4 of 170kV \npk \n1/4 of 170kV \npk \n9 \nAre test \ncertificates \nsupplied \nsupporting the \ninsulation \nlevel stated in \n6 above \nY/N \nYes \nYes \nYes \nYes \n10 \nSilica Gel \nBreather \n  \n  \n  \n  \n  \n  \n           i)    \nMake of unit \nfitted \n  \n  \n  \n  \n  \n  \n           ii)   \nSize of unit \n  \n125 \n125 \n125 \n125 \n11 \nNoise \nPollution \ndB \n48 \n48 \n48 \n48 \n12 \nVector Group \nDyn11 \nDyn11 \nDyn11 \nDyn11 \nDyn11 \n13 \nDimensions \n  \n  \n  \n  \n  \n  \n(i) Height \nMm \nVaries \nvaries \nvaries \nvaries \n  \n(ii) Width \nMm \nVaries \nvaries \nvaries \nvaries \n  \n(iii) Depth \nMm \nVaries \nvaries \nvaries \nvaries \n14 \nWinding \nMaterial \n  \n  \n  \n  \n  \n  \n(i) Primary \n  \nElectrolytic \ncopper \nElectrolytic \ncopper \nElectrolytic \ncopper \nElectrolytic \ncopper \n  \n(ii) Secondary \n  \nElectrolytic \ncopper \nElectrolytic \ncopper \nElectrolytic \ncopper \nElectrolytic \ncopper \n15 \nColour \n  \nSea Grey \nSea Grey \nSea Grey \nSea Grey \n16 \nWeight \n  \n  \n  \n  \n  \n  \n(i) Core & \nWinding \nKg \nVaries \nvaries \nvaries \nvaries \n  \n(ii) Tank & \nFitting \nKg \nVaries \nvaries \nvaries \nvaries \n  \n(iii) Weight of \nOil \nKg \nVaries \nvaries \nvaries \nvaries \n  \n(iv) Total \nWeight \nKg \nVaries \nvaries \nvaries \nvaries \n17 \nPower \nFrequency \nVoltage \n  \n  \n  \n  \n  \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 33 of 52 \n"
        },
        {
          "bbox": [
            82.7040023803711,
            86.64796447753906,
            167.66000366210938,
            155.6120147705078
          ],
          "text": "equipment \nand \nconnections \n  \n         i)   To \nearth \n"
        },
        {
          "bbox": [
            190.3699951171875,
            128.52796936035156,
            223.00999450683594,
            141.8119659423828
          ],
          "text": "kV pk \n"
        },
        {
          "bbox": [
            82.7040023803711,
            142.32801818847656,
            503.260009765625,
            197.49195861816406
          ],
          "text": "170 \n170 \n170 \n170 \n  \n         ii)   \nBetween \ncontact \n"
        },
        {
          "bbox": [
            190.3699951171875,
            156.6079864501953,
            223.00999450683594,
            169.89198303222656
          ],
          "text": "kV pk \n"
        },
        {
          "bbox": [
            233.57000732421875,
            170.40797424316406,
            300.5299987792969,
            197.49195861816406
          ],
          "text": "1/4 of 170kV \npk \n"
        },
        {
          "bbox": [
            308.8299865722656,
            170.40797424316406,
            375.78997802734375,
            197.49195861816406
          ],
          "text": "1/4 of 170kV \npk \n"
        },
        {
          "bbox": [
            384.07000732421875,
            170.40797424316406,
            451.0299987792969,
            197.49195861816406
          ],
          "text": "1/4 of 170kV \npk \n"
        },
        {
          "bbox": [
            81.26399993896484,
            170.40797424316406,
            526.3240356445312,
            294.6020202636719
          ],
          "text": "1/4 of 170kV \npk \n9 \nAre test \ncertificates \nsupplied \nsupporting the \ninsulation \nlevel stated in \n6 above \n"
        },
        {
          "bbox": [
            194.80999755859375,
            198.4879913330078,
            218.4499969482422,
            211.77198791503906
          ],
          "text": "Y/N \n"
        },
        {
          "bbox": [
            78.26399993896484,
            281.3180236816406,
            503.6199951171875,
            322.6819763183594
          ],
          "text": "Yes \nYes \nYes \nYes \n10 \nSilica Gel \nBreather \n"
        },
        {
          "bbox": [
            203.69000244140625,
            295.5979919433594,
            209.69000244140625,
            308.8819885253906
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            82.7040023803711,
            309.3979797363281,
            495.82000732421875,
            364.6820068359375
          ],
          "text": "  \n  \n  \n  \n  \n           i)    \nMake of unit \nfitted \n"
        },
        {
          "bbox": [
            203.69000244140625,
            323.7980041503906,
            209.69000244140625,
            337.0820007324219
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            82.7040023803711,
            351.39801025390625,
            495.82000732421875,
            392.7619934082031
          ],
          "text": "  \n  \n  \n  \n  \n           ii)   \nSize of unit \n"
        },
        {
          "bbox": [
            203.69000244140625,
            365.6780090332031,
            209.69000244140625,
            378.9620056152344
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            78.26399993896484,
            379.4779968261719,
            503.260009765625,
            420.8420104980469
          ],
          "text": "125 \n125 \n125 \n125 \n11 \nNoise \nPollution \n"
        },
        {
          "bbox": [
            198.1699981689453,
            393.75799560546875,
            215.2100067138672,
            407.0419921875
          ],
          "text": "dB \n"
        },
        {
          "bbox": [
            78.26399993896484,
            407.5580139160156,
            510.5799865722656,
            522.7420043945312
          ],
          "text": "48 \n48 \n48 \n48 \n12 \nVector Group \nDyn11 \nDyn11 \nDyn11 \nDyn11 \nDyn11 \n13 \nDimensions \n  \n  \n  \n  \n  \n  \n(i) Height \nMm \nVaries \nvaries \nvaries \nvaries \n  \n(ii) Width \nMm \nVaries \nvaries \nvaries \nvaries \n  \n(iii) Depth \nMm \nVaries \nvaries \nvaries \nvaries \n14 \nWinding \nMaterial \n"
        },
        {
          "bbox": [
            203.69000244140625,
            495.65802001953125,
            209.69000244140625,
            508.9420166015625
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            82.7040023803711,
            509.4580383300781,
            495.82000732421875,
            537.261962890625
          ],
          "text": "  \n  \n  \n  \n  \n(i) Primary \n  \nElectrolytic \n"
        },
        {
          "bbox": [
            249.1699981689453,
            537.5379638671875,
            284.80999755859375,
            550.8219604492188
          ],
          "text": "copper \n"
        },
        {
          "bbox": [
            312.9100036621094,
            523.7379760742188,
            371.6860046386719,
            537.02197265625
          ],
          "text": "Electrolytic \n"
        },
        {
          "bbox": [
            324.42999267578125,
            537.5379638671875,
            360.07000732421875,
            550.8219604492188
          ],
          "text": "copper \n"
        },
        {
          "bbox": [
            388.1499938964844,
            523.7379760742188,
            446.9259948730469,
            537.02197265625
          ],
          "text": "Electrolytic \n"
        },
        {
          "bbox": [
            399.6700134277344,
            537.5379638671875,
            435.3399963378906,
            550.8219604492188
          ],
          "text": "copper \n"
        },
        {
          "bbox": [
            463.4200134277344,
            523.7379760742188,
            522.196044921875,
            537.02197265625
          ],
          "text": "Electrolytic \n"
        },
        {
          "bbox": [
            82.7040023803711,
            537.5379638671875,
            510.5799865722656,
            565.3419799804688
          ],
          "text": "copper \n  \n(ii) Secondary \n  \nElectrolytic \n"
        },
        {
          "bbox": [
            249.1699981689453,
            565.6179809570312,
            284.80999755859375,
            578.9019775390625
          ],
          "text": "copper \n"
        },
        {
          "bbox": [
            312.9100036621094,
            551.8179931640625,
            371.6860046386719,
            565.1019897460938
          ],
          "text": "Electrolytic \n"
        },
        {
          "bbox": [
            324.42999267578125,
            565.6179809570312,
            360.07000732421875,
            578.9019775390625
          ],
          "text": "copper \n"
        },
        {
          "bbox": [
            388.1499938964844,
            551.8179931640625,
            446.9259948730469,
            565.1019897460938
          ],
          "text": "Electrolytic \n"
        },
        {
          "bbox": [
            399.6700134277344,
            565.6179809570312,
            435.3399963378906,
            578.9019775390625
          ],
          "text": "copper \n"
        },
        {
          "bbox": [
            463.4200134277344,
            551.8179931640625,
            522.196044921875,
            565.1019897460938
          ],
          "text": "Electrolytic \n"
        },
        {
          "bbox": [
            78.26399993896484,
            565.6179809570312,
            516.4600219726562,
            636.501953125
          ],
          "text": "copper \n15 \nColour \n  \nSea Grey \nSea Grey \nSea Grey \nSea Grey \n16 \nWeight \n  \n  \n  \n  \n  \n  \n(i) Core & \nWinding \n"
        },
        {
          "bbox": [
            197.80999755859375,
            609.41796875,
            215.4499969482422,
            622.7019653320312
          ],
          "text": "Kg \n"
        },
        {
          "bbox": [
            82.7040023803711,
            623.2179565429688,
            508.6600036621094,
            664.6119995117188
          ],
          "text": "Varies \nvaries \nvaries \nvaries \n  \n(ii) Tank & \nFitting \n"
        },
        {
          "bbox": [
            197.80999755859375,
            637.5279541015625,
            215.4499969482422,
            650.8119506835938
          ],
          "text": "Kg \n"
        },
        {
          "bbox": [
            82.7040023803711,
            651.3280029296875,
            508.6600036621094,
            692.6919555664062
          ],
          "text": "Varies \nvaries \nvaries \nvaries \n  \n(iii) Weight of \nOil \n"
        },
        {
          "bbox": [
            197.80999755859375,
            665.6079711914062,
            215.4499969482422,
            678.8919677734375
          ],
          "text": "Kg \n"
        },
        {
          "bbox": [
            82.7040023803711,
            679.407958984375,
            508.6600036621094,
            720.77197265625
          ],
          "text": "Varies \nvaries \nvaries \nvaries \n  \n(iv) Total \nWeight \n"
        },
        {
          "bbox": [
            197.80999755859375,
            693.68798828125,
            215.4499969482422,
            706.9719848632812
          ],
          "text": "Kg \n"
        },
        {
          "bbox": [
            78.26399993896484,
            707.4879760742188,
            508.6600036621094,
            762.64794921875
          ],
          "text": "Varies \nvaries \nvaries \nvaries \n17 \nPower \nFrequency \nVoltage \n"
        },
        {
          "bbox": [
            203.69000244140625,
            721.7679443359375,
            209.69000244140625,
            735.0519409179688
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            264.04998779296875,
            749.3639526367188,
            495.82000732421875,
            762.64794921875
          ],
          "text": "  \n  \n  \n  \n"
        }
      ]
    },
    {
      "index": 33,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 34 of 52 \nWithstand \n  \n(i) H.V. \nkVrms \n70 \n70 \n70 \n70 \n  \n(ii) L.V. \nkVrms \n2.5 \n2.5 \n2.5 \n2.5 \n18 \nNumber of \nPhases \n  \n3 \n3 \n3 \n3 \n19 \nReference \nStandards \nIEC60\n076 \nIEC60074 \nIEC60075 \nIEC60076 \nIEC60076 \n \n \n15.1.2 \nAll documentation necessary to evaluate whether the equipment offered is in \naccordance with this Specification shall be submitted with the Bid. \n \n15.1.3 \nAll data entered in the Schedules of Technical Guarantees are guaranteed values by \nthe Bidder and cannot be departed from whatsoever. \n \n15.1.4 \nAll data entered in the Schedules of Informative Data are also guaranteed values by \nthe Bidder.  These data may only be altered following the Engineer's written consent. \n \n15.1.5 \nEquipment or Systems offered which are not in accordance with this Specification \nshall be listed in Schedule III-9. \n \n16.0 \nDefinitions and Abbreviations \n \n \nThe following terms may be met in these Technical Schedules and shall be \ninterpreted as follows: \n \n \nHz  \n \nshall mean hertz \n \nkW  \n \nshall mean kilowatt \n \nMW  \n \nshall mean megawatt \n \nVA (kVA, MVA) shall mean volt-ampere (kilo-, mega-) \n \nA (kA) \n \nshall mean ampere (kilo-) \n \nV (kV) \n \nshall mean volt (kilo-) \n \nW/m \n \nshall mean watt per metre \n \nAC  \n \nshall mean alternating current \n \nDC  \n \nshall mean direct current \n \nIN \n \n \nshall mean rated (nominal) current \n \nUN  \n \nshall mean rated (nominal) voltage \n \nAh  \n \nshall mean ampere-hours \n \nlm  \n \nshall mean lumen \n \nlm/w \n \nshall mean lumen per watt \n \nmin  \n \nshall mean minute \n \nmin.  \n \nshall mean minimum \n \n  (prefix) \n \nshall mean micro \n \nrms  \n \nshall mean root mean square \n \np.u.  \n \nshall mean per unit \n \np/p  \n \nshall mean peak to peak \n \nT \n \n \nshall mean Tesla \n \nkg \n \n \nshall mean kilogram \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 34 of 52 \n"
        },
        {
          "bbox": [
            78.26399993896484,
            86.64796447753906,
            501.82000732421875,
            158.01197814941406
          ],
          "text": "Withstand \n  \n(i) H.V. \nkVrms \n70 \n70 \n70 \n70 \n  \n(ii) L.V. \nkVrms \n2.5 \n2.5 \n2.5 \n2.5 \n18 \nNumber of \nPhases \n"
        },
        {
          "bbox": [
            203.69000244140625,
            130.92799377441406,
            209.69000244140625,
            144.2119903564453
          ],
          "text": "  \n"
        },
        {
          "bbox": [
            262.489990234375,
            144.7279815673828,
            497.260009765625,
            158.01197814941406
          ],
          "text": "3 \n3 \n3 \n3 \n"
        },
        {
          "bbox": [
            78.26399993896484,
            159.0080108642578,
            169.31600952148438,
            186.3319854736328
          ],
          "text": "19 \nReference \n"
        },
        {
          "bbox": [
            118.45999908447266,
            172.80799865722656,
            168.74000549316406,
            186.0919952392578
          ],
          "text": "Standards \n"
        },
        {
          "bbox": [
            189.52999877929688,
            159.0080108642578,
            220.70599365234375,
            172.29200744628906
          ],
          "text": "IEC60\n"
        },
        {
          "bbox": [
            72.02400207519531,
            172.80799865722656,
            523.1799926757812,
            380.2820129394531
          ],
          "text": "076 \nIEC60074 \nIEC60075 \nIEC60076 \nIEC60076 \n \n \n15.1.2 \nAll documentation necessary to evaluate whether the equipment offered is in \naccordance with this Specification shall be submitted with the Bid. \n \n15.1.3 \nAll data entered in the Schedules of Technical Guarantees are guaranteed values by \nthe Bidder and cannot be departed from whatsoever. \n \n15.1.4 \nAll data entered in the Schedules of Informative Data are also guaranteed values by \nthe Bidder.  These data may only be altered following the Engineer's written consent. \n \n15.1.5 \nEquipment or Systems offered which are not in accordance with this Specification \nshall be listed in Schedule III-9. \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            393.0379943847656,
            526.2919311523438,
            767.927978515625
          ],
          "text": "16.0 \nDefinitions and Abbreviations \n \n \nThe following terms may be met in these Technical Schedules and shall be \ninterpreted as follows: \n \n \nHz  \n \nshall mean hertz \n \nkW  \n \nshall mean kilowatt \n \nMW  \n \nshall mean megawatt \n \nVA (kVA, MVA) shall mean volt-ampere (kilo-, mega-) \n \nA (kA) \n \nshall mean ampere (kilo-) \n \nV (kV) \n \nshall mean volt (kilo-) \n \nW/m \n \nshall mean watt per metre \n \nAC  \n \nshall mean alternating current \n \nDC  \n \nshall mean direct current \n \nIN \n \n \nshall mean rated (nominal) current \n \nUN  \n \nshall mean rated (nominal) voltage \n \nAh  \n \nshall mean ampere-hours \n \nlm  \n \nshall mean lumen \n \nlm/w \n \nshall mean lumen per watt \n \nmin  \n \nshall mean minute \n \nmin.  \n \nshall mean minimum \n \n  (prefix) \n \nshall mean micro \n \nrms  \n \nshall mean root mean square \n \np.u.  \n \nshall mean per unit \n \np/p  \n \nshall mean peak to peak \n \nT \n \n \nshall mean Tesla \n \nkg \n \n \nshall mean kilogram \n"
        }
      ]
    },
    {
      "index": 34,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 35 of 52 \n \nN \n \n \nshall mean Newton \n \nl \n \n \nshall mean litre \n \ns or sec. \n \nshall mean second \n \nNo.  \n \nshall mean number \n \ndB  \n \nshall mean decibel \n \nAmp \n \nshall mean amperes \n \nF \n \n \nshall mean Farad \n \noC \n \n \nshall mean centigrade \n \nK \n \n \nshall mean degree Kelvin \n \nm2  \n \nshall mean square metre (mm2 for millimetre, etc) \n \nm3  \n \nshall mean cubic metre (mm3 for millimetre, etc) \n \nm3/s  \n \nshall mean cubic metres per second \n \nm \n \n \nshall mean metre \n \ncm  \n \nshall mean centimetre \n \nmm  \n \nshall mean millimetre \n \njoules \n \nshall mean joules per hour \n \ntonne \n \nshall mean metric tonne \n \n% \n \n \nshall mean percentage \n \nPascal \n \n1 N/m2 \n \ncst \n \n \nshall mean centistoke \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 35 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            454.17999267578125,
            762.2879638671875
          ],
          "text": " \nN \n \n \nshall mean Newton \n \nl \n \n \nshall mean litre \n \ns or sec. \n \nshall mean second \n \nNo.  \n \nshall mean number \n \ndB  \n \nshall mean decibel \n \nAmp \n \nshall mean amperes \n \nF \n \n \nshall mean Farad \n \noC \n \n \nshall mean centigrade \n \nK \n \n \nshall mean degree Kelvin \n \nm2  \n \nshall mean square metre (mm2 for millimetre, etc) \n \nm3  \n \nshall mean cubic metre (mm3 for millimetre, etc) \n \nm3/s  \n \nshall mean cubic metres per second \n \nm \n \n \nshall mean metre \n \ncm  \n \nshall mean centimetre \n \nmm  \n \nshall mean millimetre \n \njoules \n \nshall mean joules per hour \n \ntonne \n \nshall mean metric tonne \n \n% \n \n \nshall mean percentage \n \nPascal \n \n1 N/m2 \n \ncst \n \n \nshall mean centistoke \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 35,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 36 of 52 \n \n \n  \n   \n                                \n \n    \n \n \n \n \n \n \n \n \n \n \n    TECHNICAL SPECIFICATIONS FOR  SWER TRANSFORMERS  \n \n1.  \nPARTICULARS OF  ELECTRICAL SYSTEM  \n \n     \nUnless otherwise specified in Schedule of  Requirements,  it must be assumed \nthat the system on which the equipment will operate is : \n \na) Single Wire Earth Return (SWER) overhead-line construction and \nunderground system.  \nb) Operated at 50 Hz, with approximately sinusoidal wave form. \n \n \nc) The highest system voltage does not normally exceed the nominal \nsystem    voltage by more than 10%.   \nd) The system frequency variation does not exceed plus or minus 2.5% \nfrom    50 Hz. \n \n \nDesigns should allow for these variations. \n2. \nPARTICULARS OF ENVIRONMENT  \n  \nThe transformers shall be capable of operating under the following environmental   \nconditions. \n \na) \nAmbient  temperatures: \n \n \n(i) \nMaximum: \n \n40 °C \n \n \n(ii) \nMinimum:   \n \nminus 10 °C \n      \n \n(iii) \nMaximum daily average: 35 °C \n \nb) \nAltitude: \n \nMaximum altitude of 1 500 metres above sea level.  The design shall \nallow for reduced cooling effect due to high altitude.   \n \nc) \nThe transformers will be exposed to direct tropical sunlight. \n \n \n \nd) \nHumidity:  \n \nHumidity of 13mg per cubic metre absolute and 65% relative before \nstorms with vapour pressure of 17mmHg. \n \nTransformers will operate within the tropics and will be subjected to sudden ambient air \ntemperature changes of  the order of 10 C per hour, occurring at the onset of rain, but \nRURAL ELECTRIFICATRICATION AGENCY \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 36 of 52 \n"
        },
        {
          "bbox": [
            297.7699890136719,
            86.64796447753906,
            300.7699890136719,
            99.93196868896484
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            100.70333862304688,
            434.8600158691406,
            125.524658203125
          ],
          "text": " \n  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            126.02334594726562,
            476.3800048828125,
            193.05201721191406
          ],
          "text": "   \n                                \n \n    \n \n \n \n \n \n \n \n \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            191.9903564453125,
            526.6519775390625,
            287.5699768066406
          ],
          "text": "    TECHNICAL SPECIFICATIONS FOR  SWER TRANSFORMERS  \n \n1.  \nPARTICULARS OF  ELECTRICAL SYSTEM  \n \n     \nUnless otherwise specified in Schedule of  Requirements,  it must be assumed \nthat the system on which the equipment will operate is : \n \n"
        },
        {
          "bbox": [
            144.02000427246094,
            288.1099853515625,
            526.8219604492188,
            301.4899597167969
          ],
          "text": "a) Single Wire Earth Return (SWER) overhead-line construction and \n"
        },
        {
          "bbox": [
            162.02000427246094,
            303.95001220703125,
            278.4259948730469,
            317.3299865722656
          ],
          "text": "underground system.  \n"
        },
        {
          "bbox": [
            144.02000427246094,
            329.8699951171875,
            479.3559875488281,
            343.2499694824219
          ],
          "text": "b) Operated at 50 Hz, with approximately sinusoidal wave form. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            355.5500183105469,
            111.35599517822266,
            368.92999267578125
          ],
          "text": " \n \n"
        },
        {
          "bbox": [
            144.02000427246094,
            369.4700012207031,
            526.6881103515625,
            382.8499755859375
          ],
          "text": "c) The highest system voltage does not normally exceed the nominal \n"
        },
        {
          "bbox": [
            162.02000427246094,
            385.30999755859375,
            360.64599609375,
            398.6899719238281
          ],
          "text": "system    voltage by more than 10%.   \n"
        },
        {
          "bbox": [
            144.02000427246094,
            411.2300109863281,
            526.7621459960938,
            424.6099853515625
          ],
          "text": "d) The system frequency variation does not exceed plus or minus 2.5% \n"
        },
        {
          "bbox": [
            162.02000427246094,
            427.07000732421875,
            235.3459930419922,
            440.4499816894531
          ],
          "text": "from    50 Hz. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            452.8900146484375,
            533.1599731445312,
            757.1279907226562
          ],
          "text": " \n \nDesigns should allow for these variations. \n2. \nPARTICULARS OF ENVIRONMENT  \n  \nThe transformers shall be capable of operating under the following environmental   \nconditions. \n \na) \nAmbient  temperatures: \n \n \n(i) \nMaximum: \n \n40 °C \n \n \n(ii) \nMinimum:   \n \nminus 10 °C \n      \n \n(iii) \nMaximum daily average: 35 °C \n \nb) \nAltitude: \n \nMaximum altitude of 1 500 metres above sea level.  The design shall \nallow for reduced cooling effect due to high altitude.   \n \nc) \nThe transformers will be exposed to direct tropical sunlight. \n \n \n \nd) \nHumidity:  \n \nHumidity of 13mg per cubic metre absolute and 65% relative before \nstorms with vapour pressure of 17mmHg. \n \nTransformers will operate within the tropics and will be subjected to sudden ambient air \ntemperature changes of  the order of 10 C per hour, occurring at the onset of rain, but \n"
        },
        {
          "bbox": [
            90.02400207519531,
            145.9056854248047,
            446.8863830566406,
            164.49908447265625
          ],
          "text": "RURAL ELECTRIFICATRICATION AGENCY \n"
        }
      ]
    },
    {
      "index": 36,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 37 of 52 \nthe barometric pressure at any given place does not vary by more than approximately \n10mm Mercury.   Frequent and severe lightning storms occur during summer months, \nwith isoceraunic levels varying between 50 and 100 thunderstorm days per annum.  \nIt is the manufacturers responsibility to make himself familiar with any other climatic \nand physical conditions pertaining in Zimbabwe and to allow for all conditions in his \ndesigns. \nParticular attention should be paid in the design of all equipment to ensure that there is \nno possibility of damage to working parts or insulation through the ingress of dust, \ninsects or vermin. \n \nAll orifices and air vents should be covered by  easily replaceable weather resisting, \nfine mesh wire where practicable. \n \n3. \nSTANDARDS, UNITS AND LANGUAGE \n  \n     \nExcept where modified by the Authority's Specifications, IEC Recommendations \n(IEC 76) shall apply throughout or British Standards (BS) where they amplify the \nIEC 76. \n \n \nIn the case of conflict between the above stated Standards and this \nSpecification, the ruling of this Specification will prevail. \n \n \nAll tenders, correspondence, description upon drawings, illustrations or \ninstructions shall be in unambiguous English Language. SI Units of \nmeasurements shall be used throughout.  \n \n \n \n \nAll materials used in the manufacture of the transformers shall be new and of \nhigh commercial quality. \n \n \nThe transformers shall be manufactured to high quality standards. \n \n \nType test certificates are to be submitted with the tender for each transformer \nrating and voltage.   \n \n \nThe transformers shall be sourced from manufacturers who have ISO 9001 \nCertification or equivalent.  Documentary evidence of the ISO 9001 Certification \nshall be provided with the bid.  Manufacturers who cannot submit such \ncertification are liable to be rejected. \n \n \n4. \nTECHNICAL SCHEDULES \n \nThe Technical Schedules shall be filled in and completed by the Bidder, and \nsubmitted with the Bid. \n \na) \nAll documentation necessary to evaluate whether the equipment offered is in \naccordance with this Specification shall be submitted with the Bid. \n \nb) \nAll data entered in the Schedules of Technical Guarantees are guaranteed \nvalues by the Bidder and cannot be departed from whatsoever. \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 37 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.72001647949219,
            526.8759765625,
            762.4559936523438
          ],
          "text": "the barometric pressure at any given place does not vary by more than approximately \n10mm Mercury.   Frequent and severe lightning storms occur during summer months, \nwith isoceraunic levels varying between 50 and 100 thunderstorm days per annum.  \nIt is the manufacturers responsibility to make himself familiar with any other climatic \nand physical conditions pertaining in Zimbabwe and to allow for all conditions in his \ndesigns. \nParticular attention should be paid in the design of all equipment to ensure that there is \nno possibility of damage to working parts or insulation through the ingress of dust, \ninsects or vermin. \n \nAll orifices and air vents should be covered by  easily replaceable weather resisting, \nfine mesh wire where practicable. \n \n3. \nSTANDARDS, UNITS AND LANGUAGE \n  \n     \nExcept where modified by the Authority's Specifications, IEC Recommendations \n(IEC 76) shall apply throughout or British Standards (BS) where they amplify the \nIEC 76. \n \n \nIn the case of conflict between the above stated Standards and this \nSpecification, the ruling of this Specification will prevail. \n \n \nAll tenders, correspondence, description upon drawings, illustrations or \ninstructions shall be in unambiguous English Language. SI Units of \nmeasurements shall be used throughout.  \n \n \n \n \nAll materials used in the manufacture of the transformers shall be new and of \nhigh commercial quality. \n \n \nThe transformers shall be manufactured to high quality standards. \n \n \nType test certificates are to be submitted with the tender for each transformer \nrating and voltage.   \n \n \nThe transformers shall be sourced from manufacturers who have ISO 9001 \nCertification or equivalent.  Documentary evidence of the ISO 9001 Certification \nshall be provided with the bid.  Manufacturers who cannot submit such \ncertification are liable to be rejected. \n \n \n4. \nTECHNICAL SCHEDULES \n \nThe Technical Schedules shall be filled in and completed by the Bidder, and \nsubmitted with the Bid. \n \na) \nAll documentation necessary to evaluate whether the equipment offered is in \naccordance with this Specification shall be submitted with the Bid. \n \nb) \nAll data entered in the Schedules of Technical Guarantees are guaranteed \nvalues by the Bidder and cannot be departed from whatsoever. \n"
        }
      ]
    },
    {
      "index": 37,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 38 of 52 \n \nc) \nAll data entered in the Schedules of Informative Data are also guaranteed \nvalues by the Bidder.  These data may only be altered following the \nEngineer's written consent. \n \n \n \nTechnical schedules A and B \nSWER Distribution Transformer – Inland Application \nPhase –to neutral connected transformer with centre-tapped low-voltage \nWinding (16 kVA 19 kV/+240 V) \n \nSchedule A:  Purchaser’s specific requirements \nSchedule B:  Particulars of equipment to be supplied \nItem \nDescription \n \n \nSchedule A \nSchedule B \n1 \nIdentification \n \n \n \n \na)  Manufacturer’s name \n \n \n \n \nb)  Country of Manufacture \n \n \n \n \n \n \n \n \n2 \nConstructional requirements \n \n \n \n2.1 \nTransformer dimensions \n(shown in drawing SDT 01) \n \n \n \n \na)   Ho (max.) including surge arrester            mm \n1 600 \n \n \nb)  Wo (max.) including surge arresters           mm \n1 080 \n \n \nc)   Lo (max.)                                                          mm \n1 500 \n \n \nd)  Max. mass                                                 kg \n900 \n \n \ne)  Oil capacity                                                l \n \n \n \n \n \n \n \n2.2 \nTank  \n \n \n \n \na)  Tank type:   Sealed \n \nSealed \n \n \n                 Rigid or Corrugated \n \n \n \n \n \n \n \n \n2.3 \nBushings \n \n \n \n \n \n \n \n \n \nMV bushing: \n \nOutdoor \n \n \n    a)  Material \n \nPorcelain \n \n \n    b)  Min. creepage distance: \nmm/kV \n22 \n \n \n    c)  Stem  diameter \nmm \nM12 \n \n \n    d)  Stem  type \n \nThreaded \n \n \n \n \n \n \n \nL V bushing: \n \nOutdoor \n \n \n   a)   Material \n \nPorcelain \n \n \n   b)  Min Creepage distance:                          mm/kV \n22 \n \n \n   c)  Stem diameter \nmm \nM12 \n \n \n   d)  Stem type \n \nThreaded \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 38 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.72001647949219,
            526.639892578125,
            155.2999725341797
          ],
          "text": " \nc) \nAll data entered in the Schedules of Informative Data are also guaranteed \nvalues by the Bidder.  These data may only be altered following the \nEngineer's written consent. \n \n"
        },
        {
          "bbox": [
            90.98400115966797,
            155.64796447753906,
            507.78399658203125,
            224.2999725341797
          ],
          "text": " \n \nTechnical schedules A and B \nSWER Distribution Transformer – Inland Application \nPhase –to neutral connected transformer with centre-tapped low-voltage \n"
        },
        {
          "bbox": [
            72.02400207519531,
            224.7200164794922,
            388.6059875488281,
            279.5299987792969
          ],
          "text": "Winding (16 kVA 19 kV/+240 V) \n \nSchedule A:  Purchaser’s specific requirements \nSchedule B:  Particulars of equipment to be supplied \n"
        },
        {
          "bbox": [
            72.74400329589844,
            280.42999267578125,
            261.2659912109375,
            293.8099670410156
          ],
          "text": "Item \nDescription \n"
        },
        {
          "bbox": [
            224.92999267578125,
            294.22998046875,
            228.2659912109375,
            307.6099548339844
          ],
          "text": " \n"
        },
        {
          "bbox": [
            351.9100036621094,
            280.42999267578125,
            551.3759765625,
            293.8099670410156
          ],
          "text": " \nSchedule A \nSchedule B \n"
        },
        {
          "bbox": [
            81.74400329589844,
            306.5737609863281,
            517.4951171875,
            321.8899841308594
          ],
          "text": "1 \nIdentification \n \n \n \n"
        },
        {
          "bbox": [
            85.10399627685547,
            320.8537902832031,
            518.5960083007812,
            364.8499755859375
          ],
          "text": " \na)  Manufacturer’s name \n \n \n \n \nb)  Country of Manufacture \n \n \n \n \n \n \n \n \n"
        },
        {
          "bbox": [
            81.74400329589844,
            363.81378173828125,
            517.4951171875,
            379.1299743652344
          ],
          "text": "2 \nConstructional requirements \n \n \n \n"
        },
        {
          "bbox": [
            76.7040023803711,
            380.0299987792969,
            256.9460144042969,
            407.2099914550781
          ],
          "text": "2.1 \nTransformer dimensions \n(shown in drawing SDT 01) \n"
        },
        {
          "bbox": [
            351.9100036621094,
            378.0937805175781,
            517.4951171875,
            387.0583801269531
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            76.7040023803711,
            406.17376708984375,
            518.5960083007812,
            764.2559814453125
          ],
          "text": " \na)   Ho (max.) including surge arrester            mm \n1 600 \n \n \nb)  Wo (max.) including surge arresters           mm \n1 080 \n \n \nc)   Lo (max.)                                                          mm \n1 500 \n \n \nd)  Max. mass                                                 kg \n900 \n \n \ne)  Oil capacity                                                l \n \n \n \n \n \n \n \n2.2 \nTank  \n \n \n \n \na)  Tank type:   Sealed \n \nSealed \n \n \n                 Rigid or Corrugated \n \n \n \n \n \n \n \n \n2.3 \nBushings \n \n \n \n \n \n \n \n \n \nMV bushing: \n \nOutdoor \n \n \n    a)  Material \n \nPorcelain \n \n \n    b)  Min. creepage distance: \nmm/kV \n22 \n \n \n    c)  Stem  diameter \nmm \nM12 \n \n \n    d)  Stem  type \n \nThreaded \n \n \n \n \n \n \n \nL V bushing: \n \nOutdoor \n \n \n   a)   Material \n \nPorcelain \n \n \n   b)  Min Creepage distance:                          mm/kV \n22 \n \n \n   c)  Stem diameter \nmm \nM12 \n \n \n   d)  Stem type \n \nThreaded \n \n \n \n"
        }
      ]
    },
    {
      "index": 38,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 39 of 52 \n \nPhase-to-neutral connected transformer with centre tapped low voltage \nWinding (16 kVA 19 kV/+240 V) \nItem  Description \n \nSchedule A Schedule B \n2.4 \nDehydrating breathers \n \nNot required  \n2.5 \nOil-level  gauges \n \nNot required  \n \nDrain Valve \n \nNot required  \n2.6 \nEarthing  terminals \n \n \n \n \na)  Distance between L V earth terminal \nand  neutral bushing.                                   \n \nmm \n \n250 to 300 \n \n \n \n \n \n \n2.7 \nPole-mounting brackets \n(as shown in drawing SDT 01) \n \n \n \n \na)  Mo                                                          \nmm \n400 \n \n \nb)  h1 (max.)                                                \nmm \n400 \n \n \nc)  W1 (max.)                                               \nmm \n450 \n \n \nd)  Provide clamp and threaded rods \n \nYes  \n \n \n \n \n \n \n2.8 \nWinding material          HV \n \nCopper  \n \n \n                                     LV \n \nCopper  \n \n \n \n \n \n \n3 \nElectrical requirements \n \n \n \n3.1 \nRating  \n \n \n \n \na)   Nominal rating                                       \nkVA \n16 \n \n \nb)  Rated  primary voltage                           \nkV \n19 \n \n \nc)  Rated secondary no-load voltage           \nV \n+240 \n \n \nd)  BIL                                                          \nkV \n200 \n \n \ne)  Number of phases \n \n1 ph \n \n \nf)  Vector symbol \n \nN/A \n \n \n \n \n \n \n3.2 \nLosses \n \n \n \n \n \na)   No-load losses, P1                                 \n \nkW \n \n0.1 max \n \n \n \nb)  Load losses; Pc                                       \n \nkW \n \n0.4 max \n \n \nc)  cost per kW of no-load losses; C1                USD/kW $1 531.02 \n \n \nd)  cost per kW of load losses, Cc               USD/kW $181.79 \n \n \n \n \n \n \n3.3 \nImpedance Voltage \n \n \n \n \na) Impedance at principle tapping \n% \n≤4.5 \n \n \nb) X/R ratio \n \nxxxxxxxx \n \nItem Description \n \n \nSchedule A Schedule B \n4.0 \nRating Plate and Diagram information \nRequirements \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 39 of 52 \n"
        },
        {
          "bbox": [
            94.34400177001953,
            86.72001647949219,
            504.5559997558594,
            113.9000015258789
          ],
          "text": " \nPhase-to-neutral connected transformer with centre tapped low voltage \n"
        },
        {
          "bbox": [
            72.02400207519531,
            114.31999206542969,
            542.2559814453125,
            227.2999725341797
          ],
          "text": "Winding (16 kVA 19 kV/+240 V) \nItem  Description \n \nSchedule A Schedule B \n2.4 \nDehydrating breathers \n \nNot required  \n2.5 \nOil-level  gauges \n \nNot required  \n \nDrain Valve \n \nNot required  \n2.6 \nEarthing  terminals \n \n \n \n \na)  Distance between L V earth terminal \nand  neutral bushing.                                   \n"
        },
        {
          "bbox": [
            352.2699890136719,
            200.11997985839844,
            375.64599609375,
            227.2999725341797
          ],
          "text": " \nmm \n"
        },
        {
          "bbox": [
            396.07000732421875,
            200.11997985839844,
            476.83599853515625,
            227.2999725341797
          ],
          "text": " \n250 to 300 \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            228.1999969482422,
            476.83599853515625,
            269.6600036621094
          ],
          "text": " \n \n \n \n \n2.7 \nPole-mounting brackets \n(as shown in drawing SDT 01) \n"
        },
        {
          "bbox": [
            362.2300109863281,
            242.47996520996094,
            476.83599853515625,
            255.85997009277344
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            270.59002685546875,
            476.83599853515625,
            555.9183959960938
          ],
          "text": " \na)  Mo                                                          \nmm \n400 \n \n \nb)  h1 (max.)                                                \nmm \n400 \n \n \nc)  W1 (max.)                                               \nmm \n450 \n \n \nd)  Provide clamp and threaded rods \n \nYes  \n \n \n \n \n \n \n2.8 \nWinding material          HV \n \nCopper  \n \n \n                                     LV \n \nCopper  \n \n \n \n \n \n \n3 \nElectrical requirements \n \n \n \n3.1 \nRating  \n \n \n \n \na)   Nominal rating                                       \nkVA \n16 \n \n \nb)  Rated  primary voltage                           \nkV \n19 \n \n \nc)  Rated secondary no-load voltage           \nV \n+240 \n \n \nd)  BIL                                                          \nkV \n200 \n \n \ne)  Number of phases \n \n1 ph \n \n \nf)  Vector symbol \n \nN/A \n \n \n \n \n \n \n3.2 \nLosses \n \n \n \n \n \na)   No-load losses, P1                                 \n"
        },
        {
          "bbox": [
            353.5899963378906,
            528.010009765625,
            374.20599365234375,
            555.1900024414062
          ],
          "text": " \nkW \n"
        },
        {
          "bbox": [
            396.07000732421875,
            528.010009765625,
            476.83599853515625,
            555.1900024414062
          ],
          "text": " \n0.1 max \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            556.0899658203125,
            336.4460144042969,
            583.9984130859375
          ],
          "text": " \n \nb)  Load losses; Pc                                       \n"
        },
        {
          "bbox": [
            353.5899963378906,
            556.0899658203125,
            374.20599365234375,
            583.27001953125
          ],
          "text": " \nkW \n"
        },
        {
          "bbox": [
            396.07000732421875,
            556.0899658203125,
            476.83599853515625,
            583.27001953125
          ],
          "text": " \n0.4 max \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            584.1700439453125,
            476.83599853515625,
            598.2783813476562
          ],
          "text": " \nc)  cost per kW of no-load losses; C1                USD/kW $1 531.02 \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            608.0499877929688,
            476.83599853515625,
            622.1583862304688
          ],
          "text": " \nd)  cost per kW of load losses, Cc               USD/kW $181.79 \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            630.6099853515625,
            476.83599853515625,
            686.8599853515625
          ],
          "text": " \n \n \n \n \n3.3 \nImpedance Voltage \n \n \n \n \na) Impedance at principle tapping \n% \n≤4.5 \n \n \nb) X/R ratio \n \nxxxxxxxx \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            711.760009765625,
            176.87599182128906,
            725.1400146484375
          ],
          "text": "Item Description \n"
        },
        {
          "bbox": [
            107.54000091552734,
            725.5599975585938,
            110.8759994506836,
            738.9400024414062
          ],
          "text": " \n"
        },
        {
          "bbox": [
            362.2300109863281,
            711.760009765625,
            542.2559814453125,
            725.1400146484375
          ],
          "text": " \nSchedule A Schedule B \n"
        },
        {
          "bbox": [
            72.02400207519531,
            739.8359985351562,
            310.9159851074219,
            767.0159912109375
          ],
          "text": "4.0 \nRating Plate and Diagram information \nRequirements \n"
        },
        {
          "bbox": [
            362.2300109863281,
            739.8359985351562,
            476.83599853515625,
            753.2160034179688
          ],
          "text": " \n \n \n"
        }
      ]
    },
    {
      "index": 39,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 40 of 52 \n \n \n \n \n \n \nI) \nManufacturer \n \nRequired \n \n \nii) \nSize in Kva \n \nRequired \n \n \niii) \nVoltage rating \n \nRequired \n \n \niv) \nYear of manufacture \n \nRequired \n \n \nv) \nTotal weight \n \nRequired \n \n \nvi) \nFull load loss  \n \nRequired \n \n \nvii) \nNo load loss \n \nRequired \n \n \nviii) \nVolume of oil in litres \n \nRequired \n \n \nix) \nREA Tender number \n \nRequired \n \n \nx) \nREA order number \n \nRequired \n \n \nxi) \nPercentage impedance \n \nRequired \n \n \nxii) \nVoltage table at various tap \npositions \n \nRequired \n \n \n \n \n \n \n5.0 \nTests \n \n \n \n5.1 \nType Tests \n \n \n \n \na) Temperature-rise test \n \nTest Report \nNumber \n \n \nb) Lightning impulse test chopped on \ntail \n \nTest Report \nNumber \n \n \nc) Short-Circuit withstand test \n \nTest Report \nNumber \n \n \nd) Pollution test \n \nTest Report \nNumber \n \n \ne) Equivalent disturbing current test \n \nTest Report \nNumber \n \nItem Description \n \nShedule A \nSchedule B \n5.2 \nRoutine Tests \n \n \n \n \na) Measurement of winding \nresistance \n \nTest Report \nNumber \n \n \nb) Measurement of voltage ratio and \ncheck of phase displacement \n \nTest Report \nNumber \n \n \nc) Measurement of short-circuit \nimpedance and load loss \n \nTest Report \nNumber \n \n \nd) Measurement of no-load loss and \ncurrent \n \nTest Report \nNumber \n \n \ne) 480V across outer terminals \n \nTest Report \nNumber \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 40 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            87.19999694824219,
            476.83599853515625,
            114.8599624633789
          ],
          "text": " \n \n \n \n \n \nI) \nManufacturer \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            122.72001647949219,
            476.83599853515625,
            136.1000213623047
          ],
          "text": " \nii) \nSize in Kva \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            142.87998962402344,
            476.83599853515625,
            242.0599822998047
          ],
          "text": " \niii) \nVoltage rating \n \nRequired \n \n \niv) \nYear of manufacture \n \nRequired \n \n \nv) \nTotal weight \n \nRequired \n \n \nvi) \nFull load loss  \n \nRequired \n \n \nvii) \nNo load loss \n \nRequired \n \n \nviii) \nVolume of oil in litres \n \nRequired \n \n \nix) \nREA Tender number \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            250.28001403808594,
            476.83599853515625,
            263.6600036621094
          ],
          "text": " \nx) \nREA order number \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            272.8699951171875,
            476.83599853515625,
            314.3299865722656
          ],
          "text": " \nxi) \nPercentage impedance \n \nRequired \n \n \nxii) \nVoltage table at various tap \npositions \n"
        },
        {
          "bbox": [
            362.2300109863281,
            287.1500244140625,
            476.83599853515625,
            300.5299987792969
          ],
          "text": " \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            315.22998046875,
            476.83599853515625,
            385.2499694824219
          ],
          "text": " \n \n \n \n \n5.0 \nTests \n \n \n \n5.1 \nType Tests \n \n \n \n \na) Temperature-rise test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            358.07000732421875,
            476.83599853515625,
            371.4499816894531
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            386.27001953125,
            329.10205078125,
            399.6499938964844
          ],
          "text": " \nb) Lightning impulse test chopped on \n"
        },
        {
          "bbox": [
            143.5399932861328,
            400.07000732421875,
            162.23599243164062,
            413.4499816894531
          ],
          "text": "tail \n"
        },
        {
          "bbox": [
            362.2300109863281,
            386.27001953125,
            462.1300354003906,
            413.4499816894531
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            386.27001953125,
            476.83599853515625,
            399.6499938964844
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            414.3500061035156,
            462.1300354003906,
            441.52996826171875
          ],
          "text": " \nc) Short-Circuit withstand test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            414.3500061035156,
            476.83599853515625,
            427.72998046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            442.42999267578125,
            462.1300354003906,
            469.6299743652344
          ],
          "text": " \nd) Pollution test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            442.42999267578125,
            476.83599853515625,
            455.8099670410156
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            470.5299987792969,
            462.1300354003906,
            497.7099914550781
          ],
          "text": " \ne) Equivalent disturbing current test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            470.5299987792969,
            476.83599853515625,
            483.90997314453125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            576.25,
            542.2559814453125,
            589.6300048828125
          ],
          "text": "Item Description \n \nShedule A \nSchedule B \n"
        },
        {
          "bbox": [
            72.02400207519531,
            612.25,
            476.83599853515625,
            639.9100341796875
          ],
          "text": "5.2 \nRoutine Tests \n \n \n \n \na) Measurement of winding \n"
        },
        {
          "bbox": [
            143.5399932861328,
            640.3599853515625,
            201.62599182128906,
            653.739990234375
          ],
          "text": "resistance \n"
        },
        {
          "bbox": [
            362.2300109863281,
            626.530029296875,
            462.1300354003906,
            653.739990234375
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            626.530029296875,
            476.83599853515625,
            639.9100341796875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            654.760009765625,
            325.5199890136719,
            668.1400146484375
          ],
          "text": " \nb) Measurement of voltage ratio and \n"
        },
        {
          "bbox": [
            143.5399932861328,
            668.5599975585938,
            301.70599365234375,
            681.9400024414062
          ],
          "text": "check of phase displacement \n"
        },
        {
          "bbox": [
            362.2300109863281,
            654.760009765625,
            462.1300354003906,
            681.9400024414062
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            654.760009765625,
            476.83599853515625,
            668.1400146484375
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            682.8400268554688,
            298.93402099609375,
            696.2200317382812
          ],
          "text": " \nc) Measurement of short-circuit \n"
        },
        {
          "bbox": [
            143.5399932861328,
            696.6400146484375,
            279.6260070800781,
            710.02001953125
          ],
          "text": "impedance and load loss \n"
        },
        {
          "bbox": [
            362.2300109863281,
            682.8400268554688,
            462.1300354003906,
            710.02001953125
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            682.8400268554688,
            476.83599853515625,
            696.2200317382812
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            710.9199829101562,
            325.0460205078125,
            724.2999877929688
          ],
          "text": " \nd) Measurement of no-load loss and \n"
        },
        {
          "bbox": [
            143.5399932861328,
            724.7200317382812,
            184.2259979248047,
            738.1000366210938
          ],
          "text": "current \n"
        },
        {
          "bbox": [
            362.2300109863281,
            710.9199829101562,
            462.18402099609375,
            738.1000366210938
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            710.9199829101562,
            476.83599853515625,
            724.2999877929688
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            738.9960327148438,
            462.1300354003906,
            766.176025390625
          ],
          "text": " \ne) 480V across outer terminals \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            738.9960327148438,
            476.83599853515625,
            752.3760375976562
          ],
          "text": " \n"
        }
      ]
    },
    {
      "index": 40,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 41 of 52 \n \nf) Separate source test \n \nTest Report \nNumber \n \n \ng) Induced overvoltage test \n \nTest Report \nNumber \n \n \nh) Measurement of paint thickness \n \nTest Report \nNumber \n \n \ni) Test for effective sealing \n \nTest Report \nNumber \n \n \n \n \n \n \n6.0 \nDrawings to be submitted with tender \n \n \n \n \na) Outline Drawing \n \nDrawing \nNumber \n \n \nb) Rating and diagram plate \n \n \n \nDrawing \nNumber \n \n \n \n \nTechnical schedules A and B \nSWER Distribution Transformer – Inland Application \nPhase –to neutral connected transformer with centre-tapped low-voltage \nWinding (32 kVA 19 kV/+240 V) \n \nSchedule A:  Purchaser’s specific requirements \nSchedule B:  Particulars of equipment to be supplied \nItem \nDescription \n \n \nSchedule A \nSchedule B \n1 \nIdentification \n \n \n \n \na)  Manufacturer’s name \n \n \n \n \nb)  Country of Manufacture \n \n \n \n \n \n \n \n \n2 \nConstructional requirements \n \n \n \n2.1 \nTransformer dimensions \n(shown in drawing SDT 01) \n \n \n \n \na)   Ho (max.) including surge arrester            mm \n1 600 \n \n \nb)  Wo (max.) including surge arresters           mm \n1 080 \n \n \nc)   Lo (max.)                                                          mm \n1 500 \n \n \nd)  Max. mass                                                 kg \n900 \n \n \ne)  Oil capacity                                                l \n \n \n \n \n \n \n \n2.2 \nTank  \n \n \n \n \na)  Tank type:   Sealed \n \nSealed \n \n \n                 Rigid or Corrugated \n \n \n \n \n \n \n \n \n2.3 \nBushings \n \n \n \n \n \n \n \n \n \nMV bushing: \n \nOutdoor \n \n \n    a)  Material \n \nPorcelain \n \n \n    b)  Min. creepage distance: \nmm/kV \n22 \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 41 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            87.19999694824219,
            462.1300354003906,
            114.3799819946289
          ],
          "text": " \nf) Separate source test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            87.19999694824219,
            476.83599853515625,
            100.57999420166016
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            115.28001403808594,
            462.1300354003906,
            142.4600067138672
          ],
          "text": " \ng) Induced overvoltage test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            115.28001403808594,
            476.83599853515625,
            128.66001892089844
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            143.35997009277344,
            462.1300354003906,
            170.54002380371094
          ],
          "text": " \nh) Measurement of paint thickness \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            143.35997009277344,
            476.83599853515625,
            156.73997497558594
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            171.5599822998047,
            462.1300354003906,
            198.73997497558594
          ],
          "text": " \ni) Test for effective sealing \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            171.5599822998047,
            476.83599853515625,
            184.9399871826172
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            199.63999938964844,
            476.83599853515625,
            255.37998962402344
          ],
          "text": " \n \n \n \n \n6.0 \nDrawings to be submitted with tender \n \n \n \n \na) Outline Drawing \n \nDrawing \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            228.1999969482422,
            476.83599853515625,
            241.5800018310547
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            256.280029296875,
            443.3020324707031,
            283.4899597167969
          ],
          "text": " \nb) Rating and diagram plate \n \n \n \nDrawing \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            256.280029296875,
            476.83599853515625,
            269.6600036621094
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            284.3900146484375,
            75.36000061035156,
            297.7699890136719
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            298.1180114746094,
            300.7699890136719,
            325.2019958496094
          ],
          "text": " \n \n"
        },
        {
          "bbox": [
            90.98400115966797,
            325.7900085449219,
            507.78399658203125,
            366.7699890136719
          ],
          "text": "Technical schedules A and B \nSWER Distribution Transformer – Inland Application \nPhase –to neutral connected transformer with centre-tapped low-voltage \n"
        },
        {
          "bbox": [
            72.02400207519531,
            367.19000244140625,
            388.6059875488281,
            421.969970703125
          ],
          "text": "Winding (32 kVA 19 kV/+240 V) \n \nSchedule A:  Purchaser’s specific requirements \nSchedule B:  Particulars of equipment to be supplied \n"
        },
        {
          "bbox": [
            72.74400329589844,
            422.8699951171875,
            261.2659912109375,
            436.2499694824219
          ],
          "text": "Item \nDescription \n"
        },
        {
          "bbox": [
            224.92999267578125,
            436.6700134277344,
            228.2659912109375,
            450.04998779296875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            351.9100036621094,
            422.8699951171875,
            551.3759765625,
            436.2499694824219
          ],
          "text": " \nSchedule A \nSchedule B \n"
        },
        {
          "bbox": [
            81.74400329589844,
            449.1337890625,
            517.4951171875,
            464.469970703125
          ],
          "text": "1 \nIdentification \n \n \n \n"
        },
        {
          "bbox": [
            85.10399627685547,
            463.43377685546875,
            518.5960083007812,
            507.3099670410156
          ],
          "text": " \na)  Manufacturer’s name \n \n \n \n \nb)  Country of Manufacture \n \n \n \n \n \n \n \n \n"
        },
        {
          "bbox": [
            81.74400329589844,
            506.2737731933594,
            517.4951171875,
            521.5900268554688
          ],
          "text": "2 \nConstructional requirements \n \n \n \n"
        },
        {
          "bbox": [
            76.7040023803711,
            522.489990234375,
            256.9460144042969,
            549.6700439453125
          ],
          "text": "2.1 \nTransformer dimensions \n(shown in drawing SDT 01) \n"
        },
        {
          "bbox": [
            351.9100036621094,
            520.5537719726562,
            517.4951171875,
            529.5183715820312
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            76.7040023803711,
            548.6338500976562,
            518.5960083007812,
            764.2559814453125
          ],
          "text": " \na)   Ho (max.) including surge arrester            mm \n1 600 \n \n \nb)  Wo (max.) including surge arresters           mm \n1 080 \n \n \nc)   Lo (max.)                                                          mm \n1 500 \n \n \nd)  Max. mass                                                 kg \n900 \n \n \ne)  Oil capacity                                                l \n \n \n \n \n \n \n \n2.2 \nTank  \n \n \n \n \na)  Tank type:   Sealed \n \nSealed \n \n \n                 Rigid or Corrugated \n \n \n \n \n \n \n \n \n2.3 \nBushings \n \n \n \n \n \n \n \n \n \nMV bushing: \n \nOutdoor \n \n \n    a)  Material \n \nPorcelain \n \n \n    b)  Min. creepage distance: \nmm/kV \n22 \n \n"
        }
      ]
    },
    {
      "index": 41,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 42 of 52 \n \n    c)  Stem  diameter \nmm \nM12 \n \n \n    d)  Stem  type \n \nThreaded \n \n \n \n \n \n \n \nL V bushing: \n \nOutdoor \n \n \n   a)   Material \n \nPorcelain \n \n \n   b)  Min Creepage distance:                          mm/kV \n22 \n \n \n   c)  Stem diameter \nmm \nM12 \n \n \n   d)  Stem type \n \nThreaded \n \n \nPhase-to-neutral connected transformer with centre tapped low voltage \nWinding (32 kVA 19 kV/+240 V) \nItem  Description \n \nSchedule A Schedule B \n2.4 \nDehydrating breathers \n \nNot required  \n2.5 \nOil-level  gauges \n \nNot required  \n \nDrain Valve \n \nNot required  \n2.6 \nEarthing  terminals \n \n \n \n \na)  Distance between L V earth terminal \nand  neutral bushing.                                   \n \nmm \n \n250 to 300 \n \n \n \n \n \n \n2.7 \nPole-mounting brackets \n(as shown in drawing SDT 01) \n \n \n \n \na)  Mo                                                          \nmm \n400 \n \n \nb)  h1 (max.)                                                \nmm \n400 \n \n \nc)  W1 (max.)                                               \nmm \n450 \n \n \nd)  Provide clamp and threaded rods \n \nYes  \n \n \n \n \n \n \n2.8 \nWinding material          HV \n \nCopper  \n \n \n                                     LV \n \nCopper  \n \n \n \n \n \n \n3 \nElectrical requirements \n \n \n \n3.1 \nRating  \n \n \n \n \na)   Nominal rating                                       \nkVA \n32 \n \n \nb)  Rated  primary voltage                           \nkV \n19 \n \n \nc)  Rated secondary no-load voltage           \nV \n+240 \n \n \nd)  BIL                                                          \nkV \n200 \n \n \ne)  Number of phases \n \n2 ph \n \n \nf)  Vector symbol \n \nxxxxxxxxx \n \n \n \n \n \n \n3.2 \nlosses \n \n \n \n \n \na)   No-load losses, P1                                 \n \nkW \n \n0.17 max \n \n \n \nb)  Load losses; Pc                                       \n \nkW \n \n0.63 max \n \n \nc)  cost per kW of no-load losses; C1                USD/kW $1 531.02 \n \n \nd)  cost per kW of load losses, Cc               USD/kW $181.79 \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 42 of 52 \n"
        },
        {
          "bbox": [
            85.10399627685547,
            87.19999694824219,
            518.5960083007812,
            228.73997497558594
          ],
          "text": " \n    c)  Stem  diameter \nmm \nM12 \n \n \n    d)  Stem  type \n \nThreaded \n \n \n \n \n \n \n \nL V bushing: \n \nOutdoor \n \n \n   a)   Material \n \nPorcelain \n \n \n   b)  Min Creepage distance:                          mm/kV \n22 \n \n \n   c)  Stem diameter \nmm \nM12 \n \n \n   d)  Stem type \n \nThreaded \n \n \nPhase-to-neutral connected transformer with centre tapped low voltage \n"
        },
        {
          "bbox": [
            72.02400207519531,
            229.16001892089844,
            542.2559814453125,
            342.16998291015625
          ],
          "text": "Winding (32 kVA 19 kV/+240 V) \nItem  Description \n \nSchedule A Schedule B \n2.4 \nDehydrating breathers \n \nNot required  \n2.5 \nOil-level  gauges \n \nNot required  \n \nDrain Valve \n \nNot required  \n2.6 \nEarthing  terminals \n \n \n \n \na)  Distance between L V earth terminal \nand  neutral bushing.                                   \n"
        },
        {
          "bbox": [
            352.2699890136719,
            314.989990234375,
            375.64599609375,
            342.16998291015625
          ],
          "text": " \nmm \n"
        },
        {
          "bbox": [
            396.07000732421875,
            314.989990234375,
            476.83599853515625,
            342.16998291015625
          ],
          "text": " \n250 to 300 \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            343.07000732421875,
            476.83599853515625,
            384.6499938964844
          ],
          "text": " \n \n \n \n \n2.7 \nPole-mounting brackets \n(as shown in drawing SDT 01) \n"
        },
        {
          "bbox": [
            362.2300109863281,
            357.4700012207031,
            476.83599853515625,
            370.8499755859375
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            385.5500183105469,
            476.83599853515625,
            670.9083862304688
          ],
          "text": " \na)  Mo                                                          \nmm \n400 \n \n \nb)  h1 (max.)                                                \nmm \n400 \n \n \nc)  W1 (max.)                                               \nmm \n450 \n \n \nd)  Provide clamp and threaded rods \n \nYes  \n \n \n \n \n \n \n2.8 \nWinding material          HV \n \nCopper  \n \n \n                                     LV \n \nCopper  \n \n \n \n \n \n \n3 \nElectrical requirements \n \n \n \n3.1 \nRating  \n \n \n \n \na)   Nominal rating                                       \nkVA \n32 \n \n \nb)  Rated  primary voltage                           \nkV \n19 \n \n \nc)  Rated secondary no-load voltage           \nV \n+240 \n \n \nd)  BIL                                                          \nkV \n200 \n \n \ne)  Number of phases \n \n2 ph \n \n \nf)  Vector symbol \n \nxxxxxxxxx \n \n \n \n \n \n \n3.2 \nlosses \n \n \n \n \n \na)   No-load losses, P1                                 \n"
        },
        {
          "bbox": [
            353.5899963378906,
            643.0,
            374.20599365234375,
            670.1799926757812
          ],
          "text": " \nkW \n"
        },
        {
          "bbox": [
            396.07000732421875,
            643.0,
            476.83599853515625,
            670.1799926757812
          ],
          "text": " \n0.17 max \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            671.0800170898438,
            336.4460144042969,
            698.9884033203125
          ],
          "text": " \n \nb)  Load losses; Pc                                       \n"
        },
        {
          "bbox": [
            353.5899963378906,
            671.0800170898438,
            374.20599365234375,
            698.260009765625
          ],
          "text": " \nkW \n"
        },
        {
          "bbox": [
            396.07000732421875,
            671.0800170898438,
            476.83599853515625,
            698.260009765625
          ],
          "text": " \n0.63 max \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            699.1600341796875,
            476.83599853515625,
            713.2683715820312
          ],
          "text": " \nc)  cost per kW of no-load losses; C1                USD/kW $1 531.02 \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            723.0400390625,
            476.83599853515625,
            737.1483764648438
          ],
          "text": " \nd)  cost per kW of load losses, Cc               USD/kW $181.79 \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            745.4760131835938,
            476.83599853515625,
            758.8560180664062
          ],
          "text": " \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 42,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 43 of 52 \n3.3 \nImpedance Voltage \n \n \n \n \nc) Impedance at principle tapping \n% \n≤4.5 \n \n \nd) X/R ratio \n \nxxxxxxxx \n \nItem Description \n \n \nSchedule A Schedule B \n4.0 \nRating Plate and Diagram information \nRequirements \n \n \n \n \n \n \n \n \n \nI) \nManufacturer \n \nRequired \n \n \nii) \nSize in kVA \n \nRequired \n \n \niii) \nVoltage rating \n \nRequired \n \n \niv) \nYear of manufacture \n \nRequired \n \n \nv) \nTotal weight \n \nRequired \n \n \nvi) \nFull load loss  \n \nRequired \n \n \nvii) \nNo load loss \n \nRequired \n \n \nviii) \nVolume of oil in litres \n \nRequired \n \n \nix) \nREA Tender number \n \nRequired \n \n \nx) \nREA order number \n \nRequired \n \n \nxi) \nPercentage impedance \n \nRequired \n \n \nxii) \nVoltage table at various tap \npositions \n \nRequired \n \n \n \n \n \n \n5.0 \nTests \n \n \n \n5.1 \nType Tests \n \n \n \n \nf) Temperature-rise test \n \nTest Report \nNumber \n \n \ng) Lightning impulse test chopped on \ntail \n \nTest Report \nNumber \n \n \nh) Short-Circuit withstand test \n \nTest Report \nNumber \n \n \ni) Pollution test \n \nTest Report \nNumber \n \n \nj) Equivalent disturbing current test \n \nTest Report \nNumber \n \nItem Description \n \nShedule A \nSchedule B \n5.2 \nRoutine Tests \n \n \n \n \nj) Measurement of winding \n \nTest Report \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 43 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            87.19999694824219,
            476.83599853515625,
            129.13999938964844
          ],
          "text": "3.3 \nImpedance Voltage \n \n \n \n \nc) Impedance at principle tapping \n% \n≤4.5 \n \n \nd) X/R ratio \n \nxxxxxxxx \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            154.0399627685547,
            176.87599182128906,
            167.4199676513672
          ],
          "text": "Item Description \n"
        },
        {
          "bbox": [
            107.54000091552734,
            167.8400115966797,
            110.8759994506836,
            181.2200164794922
          ],
          "text": " \n"
        },
        {
          "bbox": [
            362.2300109863281,
            154.0399627685547,
            542.2559814453125,
            167.4199676513672
          ],
          "text": " \nSchedule A Schedule B \n"
        },
        {
          "bbox": [
            72.02400207519531,
            182.11997985839844,
            310.9159851074219,
            209.2999725341797
          ],
          "text": "4.0 \nRating Plate and Diagram information \nRequirements \n"
        },
        {
          "bbox": [
            362.2300109863281,
            182.11997985839844,
            476.83599853515625,
            195.49998474121094
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            210.1999969482422,
            476.83599853515625,
            237.9800262451172
          ],
          "text": " \n \n \n \n \n \nI) \nManufacturer \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            245.7200164794922,
            476.83599853515625,
            259.1000061035156
          ],
          "text": " \nii) \nSize in kVA \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            266.030029296875,
            476.83599853515625,
            365.2099914550781
          ],
          "text": " \niii) \nVoltage rating \n \nRequired \n \n \niv) \nYear of manufacture \n \nRequired \n \n \nv) \nTotal weight \n \nRequired \n \n \nvi) \nFull load loss  \n \nRequired \n \n \nvii) \nNo load loss \n \nRequired \n \n \nviii) \nVolume of oil in litres \n \nRequired \n \n \nix) \nREA Tender number \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            373.42999267578125,
            476.83599853515625,
            386.8099670410156
          ],
          "text": " \nx) \nREA order number \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            395.8699951171875,
            476.83599853515625,
            437.3299865722656
          ],
          "text": " \nxi) \nPercentage impedance \n \nRequired \n \n \nxii) \nVoltage table at various tap \npositions \n"
        },
        {
          "bbox": [
            362.2300109863281,
            410.1499938964844,
            476.83599853515625,
            423.52996826171875
          ],
          "text": " \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            438.2300109863281,
            476.83599853515625,
            508.3899841308594
          ],
          "text": " \n \n \n \n \n5.0 \nTests \n \n \n \n5.1 \nType Tests \n \n \n \n \nf) Temperature-rise test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            481.21002197265625,
            476.83599853515625,
            494.5899963378906
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            509.2900390625,
            328.9880065917969,
            522.6700439453125
          ],
          "text": " \ng) Lightning impulse test chopped on \n"
        },
        {
          "bbox": [
            143.5399932861328,
            523.0899658203125,
            162.23599243164062,
            536.469970703125
          ],
          "text": "tail \n"
        },
        {
          "bbox": [
            362.2300109863281,
            509.2900390625,
            462.1300354003906,
            536.469970703125
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            509.2900390625,
            476.83599853515625,
            522.6700439453125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            537.3699951171875,
            462.1300354003906,
            564.550048828125
          ],
          "text": " \nh) Short-Circuit withstand test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            537.3699951171875,
            476.83599853515625,
            550.75
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            565.4500122070312,
            462.1300354003906,
            592.6300048828125
          ],
          "text": " \ni) Pollution test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            565.4500122070312,
            476.83599853515625,
            578.8300170898438
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            593.530029296875,
            462.1300354003906,
            620.7100219726562
          ],
          "text": " \nj) Equivalent disturbing current test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            593.530029296875,
            476.83599853515625,
            606.9100341796875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            699.4000244140625,
            542.2559814453125,
            712.780029296875
          ],
          "text": "Item Description \n \nShedule A \nSchedule B \n"
        },
        {
          "bbox": [
            72.02400207519531,
            735.39599609375,
            476.83599853515625,
            763.0560302734375
          ],
          "text": "5.2 \nRoutine Tests \n \n \n \n \nj) Measurement of winding \n \nTest Report \n \n"
        }
      ]
    },
    {
      "index": 43,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 44 of 52 \nresistance \nNumber \n \nk) Measurement of voltage ratio and \ncheck of phase displacement \n \nTest Report \nNumber \n \n \nl) Measurement of short-circuit \nimpedance and load loss \n \nTest Report \nNumber \n \n \nm) Measurement of no-load loss and \ncurrent \n \nTest Report \nNumber \n \n \nn) 480V across outer terminals \n \nTest Report \nNumber \n \n \no) Separate source test \n \nTest Report \nNumber \n \n \np) Induced overvoltage test \n \nTest Report \nNumber \n \n \nq) Measurement of paint thickness \n \nTest Report \nNumber \n \n \nr) Test for effective sealing \n \nTest Report \nNumber \n \n \n \n \n \n \n6.0 \nDrawings to be submitted with tender \n \n \n \n \nc) Outline Drawing \n \nDrawing \nNumber \n \n \nd) Rating and diagram plate \n \n \n \nDrawing \nNumber \n \n \n \n \nTechnical schedules A and B \nSWER Distribution Transformer – Inland Application \nPhase –to neutral connected transformer with centre-tapped low-voltage \nWinding (64 kVA 19 kV/+240 V) \n \nSchedule A:  Purchaser’s specific requirements \nSchedule B:  Particulars of equipment to be supplied \nItem \nDescription \n \n \nSchedule A Schedule B \n1 \nIdentification \n \n \n \n \na)  Manufacturer’s name \n \n \n \n \nb)  Country of Manufacture \n \n \n \n \n \n \n \n \n2 \nConstructional requirements \n \n \n \n2.1 \nTransformer dimensions \n(shown in drawing SDT 01) \n \n \n \n \na)   Ho (max.) including surge arrester              mm \n1 600 \n \n \nb)  Wo (max.) including surge arresters            mm \n1 080 \n \n \nc)   Lo (max.)                                                            mm \n1 500 \n \n \nd)  Max. mass                                                   kg \n900 \n \n \ne)  Oil capacity                                                 l \nxxxxxxxx \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 44 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            87.19999694824219,
            442.156005859375,
            114.8599624633789
          ],
          "text": "resistance \nNumber \n \nk) Measurement of voltage ratio and \n"
        },
        {
          "bbox": [
            143.5399932861328,
            115.28001403808594,
            301.70599365234375,
            128.66001892089844
          ],
          "text": "check of phase displacement \n"
        },
        {
          "bbox": [
            362.2300109863281,
            101.47996520996094,
            462.1300354003906,
            128.66001892089844
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            101.47996520996094,
            476.83599853515625,
            114.8599624633789
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            129.5599822998047,
            298.93402099609375,
            142.9399871826172
          ],
          "text": " \nl) Measurement of short-circuit \n"
        },
        {
          "bbox": [
            143.5399932861328,
            143.35997009277344,
            279.6260070800781,
            156.73997497558594
          ],
          "text": "impedance and load loss \n"
        },
        {
          "bbox": [
            362.2300109863281,
            129.5599822998047,
            462.1300354003906,
            156.73997497558594
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            129.5599822998047,
            476.83599853515625,
            142.9399871826172
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            157.75999450683594,
            325.0460205078125,
            171.13999938964844
          ],
          "text": " \nm) Measurement of no-load loss and \n"
        },
        {
          "bbox": [
            143.5399932861328,
            171.5599822998047,
            184.2259979248047,
            184.9399871826172
          ],
          "text": "current \n"
        },
        {
          "bbox": [
            362.2300109863281,
            157.75999450683594,
            462.1300354003906,
            184.9399871826172
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            157.75999450683594,
            476.83599853515625,
            171.13999938964844
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            185.8400115966797,
            462.1300354003906,
            213.02000427246094
          ],
          "text": " \nn) 480V across outer terminals \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            185.8400115966797,
            476.83599853515625,
            199.2200164794922
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            213.9199676513672,
            462.1300354003906,
            241.1000213623047
          ],
          "text": " \no) Separate source test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            213.9199676513672,
            476.83599853515625,
            227.2999725341797
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            241.99998474121094,
            462.1300354003906,
            269.1799621582031
          ],
          "text": " \np) Induced overvoltage test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            241.99998474121094,
            476.83599853515625,
            255.37998962402344
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            270.1099853515625,
            462.1300354003906,
            297.2900085449219
          ],
          "text": " \nq) Measurement of paint thickness \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            270.1099853515625,
            476.83599853515625,
            283.4899597167969
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            298.19000244140625,
            462.1300354003906,
            325.3699645996094
          ],
          "text": " \nr) Test for effective sealing \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            298.19000244140625,
            476.83599853515625,
            311.5699768066406
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            326.27001953125,
            476.83599853515625,
            382.1299743652344
          ],
          "text": " \n \n \n \n \n6.0 \nDrawings to be submitted with tender \n \n \n \n \nc) Outline Drawing \n \nDrawing \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            354.95001220703125,
            476.83599853515625,
            368.3299865722656
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            383.0299987792969,
            443.3020324707031,
            410.2099914550781
          ],
          "text": " \nd) Rating and diagram plate \n \n \n \nDrawing \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            383.0299987792969,
            476.83599853515625,
            396.40997314453125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            411.1100158691406,
            75.36000061035156,
            452.0899963378906
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            90.98400115966797,
            452.5299987792969,
            507.78399658203125,
            493.5099792480469
          ],
          "text": "Technical schedules A and B \nSWER Distribution Transformer – Inland Application \nPhase –to neutral connected transformer with centre-tapped low-voltage \n"
        },
        {
          "bbox": [
            72.02400207519531,
            493.92999267578125,
            388.6059875488281,
            548.7100219726562
          ],
          "text": "Winding (64 kVA 19 kV/+240 V) \n \nSchedule A:  Purchaser’s specific requirements \nSchedule B:  Particulars of equipment to be supplied \n"
        },
        {
          "bbox": [
            72.74400329589844,
            549.6099853515625,
            263.5459899902344,
            562.989990234375
          ],
          "text": "Item \nDescription \n"
        },
        {
          "bbox": [
            227.2100067138672,
            563.4100341796875,
            230.54600524902344,
            576.7900390625
          ],
          "text": " \n"
        },
        {
          "bbox": [
            356.4700012207031,
            549.6099853515625,
            551.3759765625,
            562.989990234375
          ],
          "text": " \nSchedule A Schedule B \n"
        },
        {
          "bbox": [
            81.74400329589844,
            575.7538452148438,
            517.4951171875,
            591.0700073242188
          ],
          "text": "1 \nIdentification \n \n \n \n"
        },
        {
          "bbox": [
            85.10399627685547,
            590.0338134765625,
            518.5960083007812,
            634.030029296875
          ],
          "text": " \na)  Manufacturer’s name \n \n \n \n \nb)  Country of Manufacture \n \n \n \n \n \n \n \n \n"
        },
        {
          "bbox": [
            81.74400329589844,
            632.9938354492188,
            517.4951171875,
            648.3400268554688
          ],
          "text": "2 \nConstructional requirements \n \n \n \n"
        },
        {
          "bbox": [
            76.7040023803711,
            649.239990234375,
            256.9460144042969,
            676.4200439453125
          ],
          "text": "2.1 \nTransformer dimensions \n(shown in drawing SDT 01) \n"
        },
        {
          "bbox": [
            356.4700012207031,
            647.3037719726562,
            517.4951171875,
            656.2683715820312
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            85.10399627685547,
            675.3837890625,
            518.5960083007812,
            762.2160034179688
          ],
          "text": " \na)   Ho (max.) including surge arrester              mm \n1 600 \n \n \nb)  Wo (max.) including surge arresters            mm \n1 080 \n \n \nc)   Lo (max.)                                                            mm \n1 500 \n \n \nd)  Max. mass                                                   kg \n900 \n \n \ne)  Oil capacity                                                 l \nxxxxxxxx \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 44,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 45 of 52 \n2.2 \nTank  \n \n \n \n \na)  Tank type:   Sealed \n \nSealed \n \n \n                 Rigid or Corrugated \n \n \n \n \n \n \n \n \n2.3 \nBushings \n \n \n \n \n \n \n \n \n \nMV bushing: \n \nOutdoor \n \n \n    a)  Material \n \nPorcelain \n \n \n    b)  Min. creepage distance: \nmm/kV \n22 \n \n \n    c)  Stem  diameter \nmm \nM12 \n \n \n    d)  Stem  type \n \nThreaded \n \n \n \n \n \n \n \nL V bushing: \n \nOutdoor \n \n \n   a)   Material \n \nPorcelain \n \n \n   b)  Min Creepage distance:                           mm/kV \n22 \n \n \n   c)  Stem diameter \nmm \nM12 \n \n \n   d)  Stem type \n \nThreaded \n \n \nPhase-to-neutral connected transformer with centre tapped low voltage \nWinding g(64 kVA 19 kV/+240 V) \nItem  Description \n \nSchedule A Schedule B \n2.4 \nDehydrating breathers \n \nNot required  \n2.5 \nOil-level  gauges \n \nNot required  \n \nDrain Valve \n \nNot required  \n2.6 \nEarthing  terminals \n \n \n \n \na)  Distance between L V earth terminal \nand  neutral bushing.                                   \n \nmm \n \n250 to 300 \n \n \n \n \n \n \n2.7 \nPole-mounting brackets \n(as shown in drawing SDT 01) \n \n \n \n \na)  Mo                                                          \nmm \n400 \n \n \nb)  h1 (max.)                                                \nmm \n400 \n \n \nc)  W1 (max.)                                               \nmm \n450 \n \n \nd)  Provide clamp and threaded rods \n \nYes  \n \n \n \n \n \n \n2.8 \nWinding material          HV \n \nCopper  \n \n \n                                     LV \n \nCopper  \n \n \n \n \n \n \n3 \nElectrical requirements \n \n \n \n3.1 \nRating  \n \n \n \n \na)   Nominal rating                                       \nkVA \n64 \n \n \nb)  Rated  primary voltage                           \nkV \n19 \n \n \nc)  Rated secondary no-load voltage           \nV \n+240 \n \n \nd)  BIL                                                          \nkV \n200 \n \n \ne)  Number of phases \n \n2 ph \n \n \nf)  Vector symbol \n \nxxxxxxxxx \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 45 of 52 \n"
        },
        {
          "bbox": [
            76.7040023803711,
            87.19999694824219,
            518.5960083007812,
            357.52996826171875
          ],
          "text": "2.2 \nTank  \n \n \n \n \na)  Tank type:   Sealed \n \nSealed \n \n \n                 Rigid or Corrugated \n \n \n \n \n \n \n \n \n2.3 \nBushings \n \n \n \n \n \n \n \n \n \nMV bushing: \n \nOutdoor \n \n \n    a)  Material \n \nPorcelain \n \n \n    b)  Min. creepage distance: \nmm/kV \n22 \n \n \n    c)  Stem  diameter \nmm \nM12 \n \n \n    d)  Stem  type \n \nThreaded \n \n \n \n \n \n \n \nL V bushing: \n \nOutdoor \n \n \n   a)   Material \n \nPorcelain \n \n \n   b)  Min Creepage distance:                           mm/kV \n22 \n \n \n   c)  Stem diameter \nmm \nM12 \n \n \n   d)  Stem type \n \nThreaded \n \n \nPhase-to-neutral connected transformer with centre tapped low voltage \n"
        },
        {
          "bbox": [
            72.02400207519531,
            357.95001220703125,
            542.2559814453125,
            470.9499816894531
          ],
          "text": "Winding g(64 kVA 19 kV/+240 V) \nItem  Description \n \nSchedule A Schedule B \n2.4 \nDehydrating breathers \n \nNot required  \n2.5 \nOil-level  gauges \n \nNot required  \n \nDrain Valve \n \nNot required  \n2.6 \nEarthing  terminals \n \n \n \n \na)  Distance between L V earth terminal \nand  neutral bushing.                                   \n"
        },
        {
          "bbox": [
            352.2699890136719,
            443.75,
            375.64599609375,
            470.9499816894531
          ],
          "text": " \nmm \n"
        },
        {
          "bbox": [
            396.07000732421875,
            443.75,
            476.83599853515625,
            470.9499816894531
          ],
          "text": " \n250 to 300 \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            471.8500061035156,
            476.83599853515625,
            513.3099975585938
          ],
          "text": " \n \n \n \n \n2.7 \nPole-mounting brackets \n(as shown in drawing SDT 01) \n"
        },
        {
          "bbox": [
            362.2300109863281,
            486.1300048828125,
            476.83599853515625,
            499.5099792480469
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            514.2100219726562,
            476.83599853515625,
            756.4559936523438
          ],
          "text": " \na)  Mo                                                          \nmm \n400 \n \n \nb)  h1 (max.)                                                \nmm \n400 \n \n \nc)  W1 (max.)                                               \nmm \n450 \n \n \nd)  Provide clamp and threaded rods \n \nYes  \n \n \n \n \n \n \n2.8 \nWinding material          HV \n \nCopper  \n \n \n                                     LV \n \nCopper  \n \n \n \n \n \n \n3 \nElectrical requirements \n \n \n \n3.1 \nRating  \n \n \n \n \na)   Nominal rating                                       \nkVA \n64 \n \n \nb)  Rated  primary voltage                           \nkV \n19 \n \n \nc)  Rated secondary no-load voltage           \nV \n+240 \n \n \nd)  BIL                                                          \nkV \n200 \n \n \ne)  Number of phases \n \n2 ph \n \n \nf)  Vector symbol \n \nxxxxxxxxx \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 45,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 46 of 52 \n3.2 \nlosses \n \n \n \n \n \na)   No-load losses, P1                                 \n \nkW \n \n0.29 max \n \n \n \nb)  Load losses; Pc                                       \n \nkW \n \n0.99 max \n \n \nc)  cost per kW of no-load losses; C1                USD/kW $1 531.02 \n \n \nd)  cost per kW of load losses, Cc               USD/kW $181.79 \n \n \n \n \n \n \n3.3 \nImpedance Voltage \n \n \n \n \ne) Impedance at principle tapping \n% \n≤4.5 \n \n \nf) X/R ratio \n \nxxxxxxxx \n \nItem Description \n \n \nSchedule A Schedule B \n4.0 \nRating Plate and Diagram information \nRequirements \n \n \n \n \n \n \n \n \n \nI) \nManufacturer \n \nRequired \n \n \nii) \nSize in kVA \n \nRequired \n \n \niii) \nVoltage rating \n \nRequired \n \n \niv) \nYear of manufacture \n \nRequired \n \n \nv) \nTotal weight \n \nRequired \n \n \nvi) \nFull load loss  \n \nRequired \n \n \nvii) \nNo load loss \n \nRequired \n \n \nviii) \nVolume of oil in litres \n \nRequired \n \n \nix) \nREA Tender number \n \nRequired \n \n \nx) \nREA order number \n \nRequired \n \n \nxi) \nPercentage impedance \n \nRequired \n \n \nxii) \nVoltage table at various tap \npositions \n \nRequired \n \n \n \n \n \n \n5.0 \nTests \n \n \n \n5.1 \nType Tests \n \n \n \n \nk) Temperature-rise test \n \nTest Report \nNumber \n \n \nl) Lightning impulse test chopped on \ntail \n \nTest Report \nNumber \n \n \nm) Short-Circuit withstand test \n \nTest Report \nNumber \n \n \nn) Pollution test \n \nTest Report \nNumber \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 46 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            87.19999694824219,
            476.83599853515625,
            129.38841247558594
          ],
          "text": "3.2 \nlosses \n \n \n \n \n \na)   No-load losses, P1                                 \n"
        },
        {
          "bbox": [
            353.5899963378906,
            101.47996520996094,
            374.20599365234375,
            128.66001892089844
          ],
          "text": " \nkW \n"
        },
        {
          "bbox": [
            396.07000732421875,
            101.47996520996094,
            476.83599853515625,
            128.66001892089844
          ],
          "text": " \n0.29 max \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            129.5599822998047,
            336.55401611328125,
            157.46836853027344
          ],
          "text": " \n \nb)  Load losses; Pc                                       \n"
        },
        {
          "bbox": [
            353.5899963378906,
            129.5599822998047,
            374.20599365234375,
            156.73997497558594
          ],
          "text": " \nkW \n"
        },
        {
          "bbox": [
            396.07000732421875,
            129.5599822998047,
            476.83599853515625,
            156.73997497558594
          ],
          "text": " \n0.99 max \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            157.75999450683594,
            476.83599853515625,
            171.86839294433594
          ],
          "text": " \nc)  cost per kW of no-load losses; C1                USD/kW $1 531.02 \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            181.52000427246094,
            476.83599853515625,
            195.62840270996094
          ],
          "text": " \nd)  cost per kW of load losses, Cc               USD/kW $181.79 \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            204.0800018310547,
            476.83599853515625,
            260.2999572753906
          ],
          "text": " \n \n \n \n \n3.3 \nImpedance Voltage \n \n \n \n \ne) Impedance at principle tapping \n% \n≤4.5 \n \n \nf) X/R ratio \n \nxxxxxxxx \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            285.22998046875,
            176.87599182128906,
            298.6099548339844
          ],
          "text": "Item Description \n"
        },
        {
          "bbox": [
            107.54000091552734,
            299.030029296875,
            110.8759994506836,
            312.4100036621094
          ],
          "text": " \n"
        },
        {
          "bbox": [
            362.2300109863281,
            285.22998046875,
            542.2559814453125,
            298.6099548339844
          ],
          "text": " \nSchedule A Schedule B \n"
        },
        {
          "bbox": [
            72.02400207519531,
            313.30999755859375,
            310.9159851074219,
            340.489990234375
          ],
          "text": "4.0 \nRating Plate and Diagram information \nRequirements \n"
        },
        {
          "bbox": [
            362.2300109863281,
            313.30999755859375,
            476.83599853515625,
            326.6899719238281
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            341.3900146484375,
            476.83599853515625,
            369.04998779296875
          ],
          "text": " \n \n \n \n \n \nI) \nManufacturer \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            376.9100036621094,
            476.83599853515625,
            390.28997802734375
          ],
          "text": " \nii) \nSize in kVA \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            397.07000732421875,
            476.83599853515625,
            496.2699890136719
          ],
          "text": " \niii) \nVoltage rating \n \nRequired \n \n \niv) \nYear of manufacture \n \nRequired \n \n \nv) \nTotal weight \n \nRequired \n \n \nvi) \nFull load loss  \n \nRequired \n \n \nvii) \nNo load loss \n \nRequired \n \n \nviii) \nVolume of oil in litres \n \nRequired \n \n \nix) \nREA Tender number \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            504.489990234375,
            476.83599853515625,
            517.8699951171875
          ],
          "text": " \nx) \nREA order number \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            527.050048828125,
            476.83599853515625,
            568.510009765625
          ],
          "text": " \nxi) \nPercentage impedance \n \nRequired \n \n \nxii) \nVoltage table at various tap \npositions \n"
        },
        {
          "bbox": [
            362.2300109863281,
            541.3300170898438,
            476.83599853515625,
            554.7100219726562
          ],
          "text": " \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            569.4100341796875,
            476.83599853515625,
            639.550048828125
          ],
          "text": " \n \n \n \n \n5.0 \nTests \n \n \n \n5.1 \nType Tests \n \n \n \n \nk) Temperature-rise test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            612.3699951171875,
            476.83599853515625,
            625.75
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            640.47998046875,
            328.9880065917969,
            653.8599853515625
          ],
          "text": " \nl) Lightning impulse test chopped on \n"
        },
        {
          "bbox": [
            143.5399932861328,
            654.280029296875,
            162.23599243164062,
            667.6600341796875
          ],
          "text": "tail \n"
        },
        {
          "bbox": [
            362.2300109863281,
            640.47998046875,
            462.1300354003906,
            667.6600341796875
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            640.47998046875,
            476.83599853515625,
            653.8599853515625
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            668.5599975585938,
            462.1300354003906,
            695.739990234375
          ],
          "text": " \nm) Short-Circuit withstand test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            668.5599975585938,
            476.83599853515625,
            681.9400024414062
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            696.6400146484375,
            462.1300354003906,
            723.8200073242188
          ],
          "text": " \nn) Pollution test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            696.6400146484375,
            476.83599853515625,
            710.02001953125
          ],
          "text": " \n"
        }
      ]
    },
    {
      "index": 46,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 47 of 52 \n \no) Equivalent disturbing current test \n \nTest Report \nNumber \n \nItem Description \n \nShedule A \nSchedule B \n5.2 \nRoutine Tests \n \n \n \n \ns) Measurement of winding \nresistance \n \nTest Report \nNumber \n \n \nt) Measurement of voltage ratio and \ncheck of phase displacement \n \nTest Report \nNumber \n \n \nu) Measurement of short-circuit \nimpedance and load loss \n \nTest Report \nNumber \n \n \nv) Measurement of no-load loss and \ncurrent \n \nTest Report \nNumber \n \n \nw) 480V across outer terminals \n \nTest Report \nNumber \n \n \nx) Separate source test \n \nTest Report \nNumber \n \n \ny) Induced overvoltage test \n \nTest Report \nNumber \n \n \nz) Measurement of paint thickness \n \nTest Report \nNumber \n \n \naa) Test for effective sealing \n \nTest Report \nNumber \n \n \n \n \n \n \n6.0 \nDrawings to be submitted with tender \n \n \n \n \ne) Outline Drawing \n \nDrawing \nNumber \n \n \nf) Rating and diagram plate \n \n \n \nDrawing \nNumber \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 47 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            87.19999694824219,
            462.1300354003906,
            114.3799819946289
          ],
          "text": " \no) Equivalent disturbing current test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            87.19999694824219,
            476.83599853515625,
            100.57999420166016
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            192.9199676513672,
            542.2559814453125,
            206.2999725341797
          ],
          "text": "Item Description \n \nShedule A \nSchedule B \n"
        },
        {
          "bbox": [
            72.02400207519531,
            228.9199676513672,
            476.83599853515625,
            256.6999816894531
          ],
          "text": "5.2 \nRoutine Tests \n \n \n \n \ns) Measurement of winding \n"
        },
        {
          "bbox": [
            143.5399932861328,
            257.0,
            201.62599182128906,
            270.3799743652344
          ],
          "text": "resistance \n"
        },
        {
          "bbox": [
            362.2300109863281,
            243.3199920654297,
            462.1300354003906,
            270.3799743652344
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            243.3199920654297,
            476.83599853515625,
            256.6999816894531
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            271.42999267578125,
            325.6460266113281,
            284.8099670410156
          ],
          "text": " \nt) Measurement of voltage ratio and \n"
        },
        {
          "bbox": [
            143.5399932861328,
            285.22998046875,
            301.70599365234375,
            298.6099548339844
          ],
          "text": "check of phase displacement \n"
        },
        {
          "bbox": [
            362.2300109863281,
            271.42999267578125,
            462.1300354003906,
            298.6099548339844
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            271.42999267578125,
            476.83599853515625,
            284.8099670410156
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            299.510009765625,
            298.93402099609375,
            312.8899841308594
          ],
          "text": " \nu) Measurement of short-circuit \n"
        },
        {
          "bbox": [
            143.5399932861328,
            313.30999755859375,
            279.6260070800781,
            326.6899719238281
          ],
          "text": "impedance and load loss \n"
        },
        {
          "bbox": [
            362.2300109863281,
            299.510009765625,
            462.1300354003906,
            326.6899719238281
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            299.510009765625,
            476.83599853515625,
            312.8899841308594
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            327.5899963378906,
            325.0460205078125,
            340.969970703125
          ],
          "text": " \nv) Measurement of no-load loss and \n"
        },
        {
          "bbox": [
            143.5399932861328,
            341.3900146484375,
            184.2259979248047,
            354.7699890136719
          ],
          "text": "current \n"
        },
        {
          "bbox": [
            362.2300109863281,
            327.5899963378906,
            462.1300354003906,
            354.7699890136719
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            327.5899963378906,
            476.83599853515625,
            340.969970703125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            355.6700134277344,
            462.1300354003906,
            382.8499755859375
          ],
          "text": " \nw) 480V across outer terminals \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            355.6700134277344,
            476.83599853515625,
            369.04998779296875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            383.75,
            462.1300354003906,
            410.92999267578125
          ],
          "text": " \nx) Separate source test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            383.75,
            476.83599853515625,
            397.1299743652344
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            411.83001708984375,
            462.1300354003906,
            439.0099792480469
          ],
          "text": " \ny) Induced overvoltage test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            411.83001708984375,
            476.83599853515625,
            425.2099914550781
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            440.0299987792969,
            462.1300354003906,
            467.22998046875
          ],
          "text": " \nz) Measurement of paint thickness \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            440.0299987792969,
            476.83599853515625,
            453.40997314453125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            468.1300048828125,
            462.1300354003906,
            495.3099670410156
          ],
          "text": " \naa) Test for effective sealing \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            468.1300048828125,
            476.83599853515625,
            481.5099792480469
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            496.21002197265625,
            476.83599853515625,
            551.9500122070312
          ],
          "text": " \n \n \n \n \n6.0 \nDrawings to be submitted with tender \n \n \n \n \ne) Outline Drawing \n \nDrawing \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            524.77001953125,
            476.83599853515625,
            538.1500244140625
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            552.8499755859375,
            443.3020324707031,
            580.030029296875
          ],
          "text": " \nf) Rating and diagram plate \n \n \n \nDrawing \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            552.8499755859375,
            476.83599853515625,
            566.22998046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            580.9299926757812,
            75.36000061035156,
            759.93603515625
          ],
          "text": " \n \n \n \n \n \n \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 47,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 48 of 52 \n \nTechnical schedules A and B \nSWER Isolation Transformer (475 kVA 33kV/19 kV)– Inland Application \n \nSchedule A:  Purchaser’s specific requirements \nSchedule B:  Particulars of equipment to be supplied \nItem \nDescription \n \n \nSchedule A Schedule B \n1 \nIdentification \n \n \n \n \na)  Manufacturer’s name \n \nxxxxxxx \n \n \nb)  Country of Manufacture \n \nxxxxxxx \n \n \n \n \n \n \n2 \nConstructional requirements \n \n \n \n2.1 \nTransformer dimensions \n(shown in drawing SIT 01) \n \n \n \n \na)   Ho (max.) including surge arrester              mm \n1 600 \n \n \nb)  Wo (max.) including surge arresters            mm \n1 800 \n \n \nc)   Lo (max.)                                                            mm \n1 800 \n \n \nd)  Max. mass                                                   kg \n2 200 \n \n \ne)  Oil capacity                                                 l \nxxxxxx \n \n \n \n \n \n \n2.2 \nTank  \n \n \n \n \na)  Tank type:   Sealed \n \nSealed \n \n \n                 Rigid or Corrugated \n \nxxxxxxx \n \n \n \n \n \n \n2.3 \nBushings \n \n \n \n \n \n \n \n \n \nMV bushing: \n \nOutdoor \n \n \n    a)  Material \n \nPorcelain \n \n \n    b)  Min. creepage distance: \nmm/kV \n22 \n \n \n    c)  Stem  diameter \nmm \nM12 \n \n \n    d)  Stem  type \n \nThreaded \n \n \n \n \n \n \n \nL V bushing: \n \nOutdoor \n \n \n   a)   Material \n \nPorcelain \n \n \n   b)  Creepage distance:                                  mm/kV \n22 \n \n \n   c)  Stem diameter \nmm \nM12 \n \n \n   d)  Stem type \n \nThreaded \n \n \n \nSWER Isolation Transformer (475 kVA 33kV/19 kV)– Inland Application  \nItem  Description \n \nSchedule A Schedule B \n2.4 \nDehydrating breathers \n \nNot required  \n2.5 \nOil-level  gauges \n \nNot required  \n \nDrain Valve \n \nNot required  \n2.6 \nWinding material          MV \n \nCopper  \n \n \n                                     SWER \n \nCopper  \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 48 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.72001647949219,
            75.36000061035156,
            100.10001373291016
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            100.52000427246094,
            501.4360046386719,
            169.1000213623047
          ],
          "text": "Technical schedules A and B \nSWER Isolation Transformer (475 kVA 33kV/19 kV)– Inland Application \n \nSchedule A:  Purchaser’s specific requirements \nSchedule B:  Particulars of equipment to be supplied \n"
        },
        {
          "bbox": [
            72.74400329589844,
            169.99998474121094,
            263.5459899902344,
            183.37998962402344
          ],
          "text": "Item \nDescription \n"
        },
        {
          "bbox": [
            227.2100067138672,
            183.7999725341797,
            230.54600524902344,
            197.1799774169922
          ],
          "text": " \n"
        },
        {
          "bbox": [
            356.4700012207031,
            169.99998474121094,
            551.3759765625,
            183.37998962402344
          ],
          "text": " \nSchedule A Schedule B \n"
        },
        {
          "bbox": [
            81.74400329589844,
            196.14378356933594,
            517.4951171875,
            211.4600067138672
          ],
          "text": "1 \nIdentification \n \n \n \n"
        },
        {
          "bbox": [
            85.10399627685547,
            210.42381286621094,
            518.5960083007812,
            254.4199676513672
          ],
          "text": " \na)  Manufacturer’s name \n \nxxxxxxx \n \n \nb)  Country of Manufacture \n \nxxxxxxx \n \n \n \n \n \n \n"
        },
        {
          "bbox": [
            81.74400329589844,
            253.38377380371094,
            517.4951171875,
            268.6999816894531
          ],
          "text": "2 \nConstructional requirements \n \n \n \n"
        },
        {
          "bbox": [
            76.7040023803711,
            269.6300048828125,
            251.66600036621094,
            296.8099670410156
          ],
          "text": "2.1 \nTransformer dimensions \n(shown in drawing SIT 01) \n"
        },
        {
          "bbox": [
            356.4700012207031,
            267.6637878417969,
            517.4951171875,
            276.6283874511719
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            295.7737731933594,
            542.2559814453125,
            767.7360229492188
          ],
          "text": " \na)   Ho (max.) including surge arrester              mm \n1 600 \n \n \nb)  Wo (max.) including surge arresters            mm \n1 800 \n \n \nc)   Lo (max.)                                                            mm \n1 800 \n \n \nd)  Max. mass                                                   kg \n2 200 \n \n \ne)  Oil capacity                                                 l \nxxxxxx \n \n \n \n \n \n \n2.2 \nTank  \n \n \n \n \na)  Tank type:   Sealed \n \nSealed \n \n \n                 Rigid or Corrugated \n \nxxxxxxx \n \n \n \n \n \n \n2.3 \nBushings \n \n \n \n \n \n \n \n \n \nMV bushing: \n \nOutdoor \n \n \n    a)  Material \n \nPorcelain \n \n \n    b)  Min. creepage distance: \nmm/kV \n22 \n \n \n    c)  Stem  diameter \nmm \nM12 \n \n \n    d)  Stem  type \n \nThreaded \n \n \n \n \n \n \n \nL V bushing: \n \nOutdoor \n \n \n   a)   Material \n \nPorcelain \n \n \n   b)  Creepage distance:                                  mm/kV \n22 \n \n \n   c)  Stem diameter \nmm \nM12 \n \n \n   d)  Stem type \n \nThreaded \n \n \n \nSWER Isolation Transformer (475 kVA 33kV/19 kV)– Inland Application  \nItem  Description \n \nSchedule A Schedule B \n2.4 \nDehydrating breathers \n \nNot required  \n2.5 \nOil-level  gauges \n \nNot required  \n \nDrain Valve \n \nNot required  \n2.6 \nWinding material          MV \n \nCopper  \n \n \n                                     SWER \n \nCopper  \n \n \n \n \n \n \n"
        }
      ]
    },
    {
      "index": 48,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 49 of 52 \n2.7 \nElectrical requirements \n \n \n \n \nRating  \n \n \n \n \na)   Nominal rating                                       \nkVA \n475 \n \n \nb)  Rated  primary voltage (p-to-p)              \nkV \n33 \n \n \nc)  Rated secondary voltage (p-to-g)           \nV \n19 \n \n \nd)  MV BIL                                                   \nkV \n200 \n \n \ne)  SWER BIL \n \n200 \n \n \nf)  Vector symbol \n \nxxxxxxxxx \n \n \n \n \n \n \n3 \nlosses \n \n \n \n3.1 \na)   No-load losses, P1                                 \nkW \n1.24 max \n \n \nb)  Load losses; Pc                                       \nkW \n5.35 max \n \n \nc)  cost per kW of no-load losses; C1                USD/kW $1 531.02 \n \n \nd)  cost per kW of load losses, Cc               USD/kW $181.79 \n \n \n \n \n \n \n4.0 \nRating Plate and Diagram information \nRequirements \n \n \n \n \n \n \n \n \n \nI) \nManufacturer \n \nRequired \n \n \nii) \nSize in kVA \n \nRequired \n \n \niii) \nVoltage rating \n \nRequired \n \n \niv) \nYear of manufacture \n \nRequired \n \n \nv) \nTotal weight \n \nRequired \n \n \nvi) \nFull load loss  \n \nRequired \n \n \nvii) \nNo load loss \n \nRequired \n \n \nviii) \nVolume of oil in litres \n \nRequired \n \n \nix) \nREA Tender number \n \nRequired \n \nSWER Isolation Transformer (475 kVA 33kV/19 kV)– Inland Application  \n \n \nx) \nREA order number \n \nRequired \n \n \nxi) \nPercentage impedance \n \nRequired \n \n \nxii) \nVoltage table at various tap \npositions \n \nRequired \n \n \n \n \n \n \n5.0 \nTests \n \n \n \n5.1 \nType Tests \n \n \n \n \np) Temperature-rise test \n \nTest Report \nNumber \n \n \nq) Lightning impulse test chopped on \ntail \n \nTest Report \nNumber \n \n \nr) Short-Circuit withstand test \n \nTest Report \nNumber \n \n \ns) Pollution test \n \nTest Report \nNumber \n \n \nt) Equivalent disturbing current test \n \nTest Report \nNumber \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 49 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            87.19999694824219,
            476.83599853515625,
            328.8500061035156
          ],
          "text": "2.7 \nElectrical requirements \n \n \n \n \nRating  \n \n \n \n \na)   Nominal rating                                       \nkVA \n475 \n \n \nb)  Rated  primary voltage (p-to-p)              \nkV \n33 \n \n \nc)  Rated secondary voltage (p-to-g)           \nV \n19 \n \n \nd)  MV BIL                                                   \nkV \n200 \n \n \ne)  SWER BIL \n \n200 \n \n \nf)  Vector symbol \n \nxxxxxxxxx \n \n \n \n \n \n \n3 \nlosses \n \n \n \n3.1 \na)   No-load losses, P1                                 \nkW \n1.24 max \n \n \nb)  Load losses; Pc                                       \nkW \n5.35 max \n \n \nc)  cost per kW of no-load losses; C1                USD/kW $1 531.02 \n \n \nd)  cost per kW of load losses, Cc               USD/kW $181.79 \n \n \n \n \n \n \n4.0 \nRating Plate and Diagram information \nRequirements \n"
        },
        {
          "bbox": [
            362.2300109863281,
            301.66998291015625,
            476.83599853515625,
            315.0499572753906
          ],
          "text": " \n \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            329.8699951171875,
            476.83599853515625,
            393.52996826171875
          ],
          "text": " \n \n \n \n \n \nI) \nManufacturer \n \nRequired \n \n \nii) \nSize in kVA \n \nRequired \n \n \niii) \nVoltage rating \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            398.9900207519531,
            476.83599853515625,
            483.90997314453125
          ],
          "text": " \niv) \nYear of manufacture \n \nRequired \n \n \nv) \nTotal weight \n \nRequired \n \n \nvi) \nFull load loss  \n \nRequired \n \n \nvii) \nNo load loss \n \nRequired \n \n \nviii) \nVolume of oil in litres \n \nRequired \n \n \nix) \nREA Tender number \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            492.1300048828125,
            504.7959899902344,
            531.3099975585938
          ],
          "text": "SWER Isolation Transformer (475 kVA 33kV/19 kV)– Inland Application  \n \n \nx) \nREA order number \n \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            540.489990234375,
            476.83599853515625,
            581.9500122070312
          ],
          "text": " \nxi) \nPercentage impedance \n \nRequired \n \n \nxii) \nVoltage table at various tap \npositions \n"
        },
        {
          "bbox": [
            362.2300109863281,
            554.77001953125,
            476.83599853515625,
            568.1500244140625
          ],
          "text": " \nRequired \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            582.8499755859375,
            476.83599853515625,
            652.9000244140625
          ],
          "text": " \n \n \n \n \n5.0 \nTests \n \n \n \n5.1 \nType Tests \n \n \n \n \np) Temperature-rise test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            625.6900024414062,
            476.83599853515625,
            639.0700073242188
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            653.7999877929688,
            328.9880065917969,
            667.1799926757812
          ],
          "text": " \nq) Lightning impulse test chopped on \n"
        },
        {
          "bbox": [
            143.5399932861328,
            667.5999755859375,
            162.23599243164062,
            680.97998046875
          ],
          "text": "tail \n"
        },
        {
          "bbox": [
            362.2300109863281,
            653.7999877929688,
            462.1300354003906,
            680.97998046875
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            653.7999877929688,
            476.83599853515625,
            667.1799926757812
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            682.0,
            462.1300354003906,
            709.1799926757812
          ],
          "text": " \nr) Short-Circuit withstand test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            682.0,
            476.83599853515625,
            695.3800048828125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            710.0800170898438,
            462.1300354003906,
            737.260009765625
          ],
          "text": " \ns) Pollution test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            710.0800170898438,
            476.83599853515625,
            723.4600219726562
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            738.156005859375,
            462.1300354003906,
            765.3359985351562
          ],
          "text": " \nt) Equivalent disturbing current test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            738.156005859375,
            476.83599853515625,
            751.5360107421875
          ],
          "text": " \n"
        }
      ]
    },
    {
      "index": 49,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 50 of 52 \n5.2 \nRoutine Tests \n \n \n \n \nbb) Measurement of winding \nresistance \n \nTest Report \nNumber \n \n \ncc) Measurement of voltage ratio and \ncheck of phase displacement \n \nTest Report \nNumber \n \n \ndd) Measurement of short-circuit \nimpedance and load loss \n \nTest Report \nNumber \n \n \nee) Measurement of no-load loss and \ncurrent \n \nTest Report \nNumber \n \n \nff) Separate source test \n \nTest Report \nNumber \n \n \ngg) Induced overvoltage test \n \nTest Report \nNumber \n \n \nhh) Measurement of paint thickness \n \nTest Report \nNumber \n \n \nii) Test for effective sealing \n \nTest Report \nNumber \n \n \n \n \n \n \n6.0 \nDrawings to be submitted with tender \n \n \n \n \ng) Outline Drawing \n \nDrawing \nNumber \n \n \nh) Rating and diagram plate \n \n \n \nDrawing \nNumber \n \n \nNB: \nAll transformers will be inspected by ZESA Enterprises (Pvt) Ltd before delivery to Rural \nElectrification Agency Central Stores. The cost of inspection will be borne by the supplier. \nRural Electrification Agency will accept transformers which have passed ZESA tests only.  \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 50 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            87.19999694824219,
            476.83599853515625,
            114.8599624633789
          ],
          "text": "5.2 \nRoutine Tests \n \n \n \n \nbb) Measurement of winding \n"
        },
        {
          "bbox": [
            143.5399932861328,
            115.28001403808594,
            201.62599182128906,
            128.66001892089844
          ],
          "text": "resistance \n"
        },
        {
          "bbox": [
            362.2300109863281,
            101.47996520996094,
            462.1300354003906,
            128.66001892089844
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            101.47996520996094,
            476.83599853515625,
            114.8599624633789
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            129.5599822998047,
            325.5199890136719,
            142.9399871826172
          ],
          "text": " \ncc) Measurement of voltage ratio and \n"
        },
        {
          "bbox": [
            143.5399932861328,
            143.35997009277344,
            301.70599365234375,
            156.73997497558594
          ],
          "text": "check of phase displacement \n"
        },
        {
          "bbox": [
            362.2300109863281,
            129.5599822998047,
            462.1300354003906,
            156.73997497558594
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            129.5599822998047,
            476.83599853515625,
            142.9399871826172
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            157.75999450683594,
            298.93402099609375,
            171.13999938964844
          ],
          "text": " \ndd) Measurement of short-circuit \n"
        },
        {
          "bbox": [
            143.5399932861328,
            171.5599822998047,
            279.6260070800781,
            184.9399871826172
          ],
          "text": "impedance and load loss \n"
        },
        {
          "bbox": [
            362.2300109863281,
            157.75999450683594,
            462.1300354003906,
            184.9399871826172
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            157.75999450683594,
            476.83599853515625,
            171.13999938964844
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            185.8400115966797,
            325.0460205078125,
            199.2200164794922
          ],
          "text": " \nee) Measurement of no-load loss and \n"
        },
        {
          "bbox": [
            143.5399932861328,
            199.63999938964844,
            184.2259979248047,
            213.02000427246094
          ],
          "text": "current \n"
        },
        {
          "bbox": [
            362.2300109863281,
            185.8400115966797,
            462.1300354003906,
            213.02000427246094
          ],
          "text": " \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            185.8400115966797,
            476.83599853515625,
            199.2200164794922
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            213.9199676513672,
            462.1300354003906,
            241.1000213623047
          ],
          "text": " \nff) Separate source test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            213.9199676513672,
            476.83599853515625,
            227.2999725341797
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            241.99998474121094,
            462.19598388671875,
            269.1799621582031
          ],
          "text": " \ngg) Induced overvoltage test \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            241.99998474121094,
            476.83599853515625,
            255.37998962402344
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            270.1099853515625,
            462.1300354003906,
            297.2900085449219
          ],
          "text": " \nhh) Measurement of paint thickness \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            270.1099853515625,
            476.83599853515625,
            283.4899597167969
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            298.19000244140625,
            462.1300354003906,
            325.3699645996094
          ],
          "text": " \nii) Test for effective sealing \n \nTest Report \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            298.19000244140625,
            476.83599853515625,
            311.5699768066406
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            326.27001953125,
            476.83599853515625,
            382.1299743652344
          ],
          "text": " \n \n \n \n \n6.0 \nDrawings to be submitted with tender \n \n \n \n \ng) Outline Drawing \n \nDrawing \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            354.95001220703125,
            476.83599853515625,
            368.3299865722656
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            383.0299987792969,
            443.3020324707031,
            410.2099914550781
          ],
          "text": " \nh) Rating and diagram plate \n \n \n \nDrawing \nNumber \n"
        },
        {
          "bbox": [
            473.5,
            383.0299987792969,
            476.83599853515625,
            396.40997314453125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            411.0379943847656,
            525.9558715820312,
            489.86199951171875
          ],
          "text": " \nNB: \nAll transformers will be inspected by ZESA Enterprises (Pvt) Ltd before delivery to Rural \nElectrification Agency Central Stores. The cost of inspection will be borne by the supplier. \nRural Electrification Agency will accept transformers which have passed ZESA tests only.  \n \n"
        }
      ]
    },
    {
      "index": 50,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 51 of 52 \n                             \nAnnexure 1 \nDECLARATION ON NON-ENGAGEMENT IN CORRUPT OR FRAUDULENT \nPRACTICES FORM \n \nThe Chief Executive \nRural Electrification Fund \n6th Floor Megawatt House \n44 Samora Machel Ave \nP. Bag A250,Avondale \nHarare \nZimbabwe \n \nTENDER NUMBER: ____________________________________________________ \nTENDER DESCRIPTION: ___________________________________________________ \nI___________________________________ the undersigned (Director of Company) on \nbehalf of ____________________________________ (Name of Organisation), do hereby \ndeclare that our organization has not been engaged in any corrupt or unethical practices \nduring the subsistence of our organisation. \nName in Full ___________________________________  \nI. D. Number ___________________________________ \nSignature ______________________________________ \nDate __________________________________________ \n \n \n \n \n \n \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 51 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            384.6700134277344,
            113.97200775146484
          ],
          "text": "                             \nAnnexure 1 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            120.48799133300781,
            493.59796142578125,
            147.5719757080078
          ],
          "text": "DECLARATION ON NON-ENGAGEMENT IN CORRUPT OR FRAUDULENT \nPRACTICES FORM \n"
        },
        {
          "bbox": [
            72.02400207519531,
            159.8479766845703,
            75.02400207519531,
            173.13197326660156
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            185.64796447753906,
            174.3800048828125,
            198.9319610595703
          ],
          "text": "The Chief Executive \n"
        },
        {
          "bbox": [
            72.02400207519531,
            211.44801330566406,
            201.0500030517578,
            224.7320098876953
          ],
          "text": "Rural Electrification Fund \n"
        },
        {
          "bbox": [
            72.02400207519531,
            235.25634765625,
            200.92999267578125,
            250.53199768066406
          ],
          "text": "6th Floor Megawatt House \n"
        },
        {
          "bbox": [
            72.02400207519531,
            263.0480041503906,
            188.69000244140625,
            276.3320007324219
          ],
          "text": "44 Samora Machel Ave \n"
        },
        {
          "bbox": [
            72.02400207519531,
            288.8780212402344,
            186.41000366210938,
            302.1620178222656
          ],
          "text": "P. Bag A250,Avondale \n"
        },
        {
          "bbox": [
            72.02400207519531,
            314.6780090332031,
            107.66000366210938,
            327.9620056152344
          ],
          "text": "Harare \n"
        },
        {
          "bbox": [
            72.02400207519531,
            340.4779968261719,
            126.37999725341797,
            353.7619934082031
          ],
          "text": "Zimbabwe \n"
        },
        {
          "bbox": [
            72.02400207519531,
            366.51800537109375,
            75.02400207519531,
            379.802001953125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            392.3179931640625,
            500.5,
            405.60198974609375
          ],
          "text": "TENDER NUMBER: ____________________________________________________ \n"
        },
        {
          "bbox": [
            72.02400207519531,
            418.1180114746094,
            524.3800048828125,
            431.4020080566406
          ],
          "text": "TENDER DESCRIPTION: ___________________________________________________ \n"
        },
        {
          "bbox": [
            72.02400207519531,
            443.6780090332031,
            508.88800048828125,
            498.3819885253906
          ],
          "text": "I___________________________________ the undersigned (Director of Company) on \nbehalf of ____________________________________ (Name of Organisation), do hereby \ndeclare that our organization has not been engaged in any corrupt or unethical practices \nduring the subsistence of our organisation. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            510.8979797363281,
            354.42999267578125,
            524.1819458007812
          ],
          "text": "Name in Full ___________________________________  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            536.697998046875,
            352.0299987792969,
            549.9819946289062
          ],
          "text": "I. D. Number ___________________________________ \n"
        },
        {
          "bbox": [
            72.02400207519531,
            562.4979858398438,
            352.0299987792969,
            575.781982421875
          ],
          "text": "Signature ______________________________________ \n"
        },
        {
          "bbox": [
            72.02400207519531,
            588.2979736328125,
            352.75,
            601.5819702148438
          ],
          "text": "Date __________________________________________ \n"
        },
        {
          "bbox": [
            72.02400207519531,
            614.0979614257812,
            75.02400207519531,
            627.3819580078125
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            640.16796875,
            75.02400207519531,
            653.4519653320312
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            665.7279663085938,
            75.02400207519531,
            679.011962890625
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            691.5279541015625,
            75.02400207519531,
            704.8119506835938
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            717.3280029296875,
            75.02400207519531,
            730.6119995117188
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            743.1239624023438,
            75.02400207519531,
            756.407958984375
          ],
          "text": " \n"
        }
      ]
    },
    {
      "index": 51,
      "width": 595.4400024414062,
      "height": 841.6799926757812,
      "rotation": 0,
      "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \nPART 3 \nCONTRACT \n \n \nPage 52 of 52 \n \nAnnexure 2 \nLETTER OF TENDER (TENDER FORM) \nNAME OF TENDER: Supply & Delivery of  transformers \nTender Number REF/………../………/2018 \nTO:      The Chief Executive \n             Rural Electrification Fund (REF) \n            6th Megawatt House,44 Samora Machel Avenue, Harare, Zimbabwe \nWe, [insert name of Tenderer], herewith enclose a Tender for selection of our firm as \nContractor/Supplier for …………………………………………………………… \nWe have examined the Conditions of Contract, Employer's Requirements, Schedules, the \nattached. Appendix and Addenda Nos __ of the above-named Works. We have examined, \nunderstood and checked these documents and have ascertained that they contain no errors or \nother defects. We accordingly offer to design, execute and complete the Works and remedy \nany defects therein, in conformity with this Tender which includes all these documents and \nthe enclosed Proposal, for the lump tender sum of: \nUSD/RTGS___________________________________ \n  \nWe agree to abide by this Tender until _date__/_month___/_year___ [i.e. ______ days from \nthe tender opening date] and it shall remain binding upon us and may be accepted at any time \nbefore that date. We acknowledge that the Appendix to Tender forms part of this Letter of \nTender. \nIf this offer is accepted, we will provide the specified Performance Security, commence the \nWorks as soon as is reasonably practicable after the Commencement Date, and complete the \nWorks in accordance with the above-named documents within the Time for Completion. We \nguarantee that the Works will then conform to the Schedule of Guarantees. \nUnless and until a formal Agreement is prepared and executed, this Letter of Tender, together \nwith your written acceptance thereof, shall constitute a binding contract between us. Our \nTender is binding upon us and subject to the modifications resulting from pre-award contract \nnegotiations. \nWe understand that you are not bound to accept the lowest or any tender you may receive. \nSignature _____________________________ \n in the capacity of ___________ \nDuly authorized to sign tenders for and on behalf of _________________ \nAddress:  \n_______________________________________ \n \nDate:  \n_______________________________________ \n",
      "image_ratio": 0.0,
      "blank": false,
      "risks": [],
      "native_blocks": [
        {
          "bbox": [
            72.02400207519531,
            31.770328521728516,
            428.8600158691406,
            63.39262390136719
          ],
          "text": "BIDDING DOCUMENT FOR THE PROCUREMENT OF VARIOUS \nTRANSFORMERS. REF/Inter/05/08/2021 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            69.96560668945312,
            178.4300079345703,
            80.99132537841797
          ],
          "text": "PART 3 \nCONTRACT \n"
        },
        {
          "bbox": [
            72.02400207519531,
            781.7816162109375,
            74.51399993896484,
            792.807373046875
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            799.3015747070312,
            318.7599792480469,
            810.3273315429688
          ],
          "text": " \nPage 52 of 52 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            86.64796447753906,
            75.02400207519531,
            99.93196868896484
          ],
          "text": " \n"
        },
        {
          "bbox": [
            72.02400207519531,
            112.44801330566406,
            131.3000030517578,
            125.73201751708984
          ],
          "text": "Annexure 2 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            138.4879913330078,
            297.04998779296875,
            151.77198791503906
          ],
          "text": "LETTER OF TENDER (TENDER FORM) \n"
        },
        {
          "bbox": [
            72.02400207519531,
            164.04798889160156,
            353.95001220703125,
            177.3319854736328
          ],
          "text": "NAME OF TENDER: Supply & Delivery of  transformers \n"
        },
        {
          "bbox": [
            72.02400207519531,
            190.0879669189453,
            297.04998779296875,
            203.37196350097656
          ],
          "text": "Tender Number REF/………../………/2018 \n"
        },
        {
          "bbox": [
            72.02400207519531,
            215.64796447753906,
            211.61000061035156,
            228.9319610595703
          ],
          "text": "TO:      The Chief Executive \n"
        },
        {
          "bbox": [
            72.02400207519531,
            241.44801330566406,
            272.92999267578125,
            254.7320098876953
          ],
          "text": "             Rural Electrification Fund (REF) \n"
        },
        {
          "bbox": [
            72.02400207519531,
            265.25634765625,
            436.8999938964844,
            280.5619812011719
          ],
          "text": "            6th Megawatt House,44 Samora Machel Avenue, Harare, Zimbabwe \n"
        },
        {
          "bbox": [
            72.02400207519531,
            293.0780334472656,
            484.7540588378906,
            320.1620178222656
          ],
          "text": "We, [insert name of Tenderer], herewith enclose a Tender for selection of our firm as \nContractor/Supplier for …………………………………………………………… \n"
        },
        {
          "bbox": [
            72.02400207519531,
            332.6780090332031,
            518.4580078125,
            428.7619934082031
          ],
          "text": "We have examined the Conditions of Contract, Employer's Requirements, Schedules, the \nattached. Appendix and Addenda Nos __ of the above-named Works. We have examined, \nunderstood and checked these documents and have ascertained that they contain no errors or \nother defects. We accordingly offer to design, execute and complete the Works and remedy \nany defects therein, in conformity with this Tender which includes all these documents and \nthe enclosed Proposal, for the lump tender sum of: \nUSD/RTGS___________________________________ \n  \n"
        },
        {
          "bbox": [
            72.02400207519531,
            441.27801513671875,
            523.1040649414062,
            495.98199462890625
          ],
          "text": "We agree to abide by this Tender until _date__/_month___/_year___ [i.e. ______ days from \nthe tender opening date] and it shall remain binding upon us and may be accepted at any time \nbefore that date. We acknowledge that the Appendix to Tender forms part of this Letter of \nTender. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            508.4980163574219,
            519.9019775390625,
            563.1819458007812
          ],
          "text": "If this offer is accepted, we will provide the specified Performance Security, commence the \nWorks as soon as is reasonably practicable after the Commencement Date, and complete the \nWorks in accordance with the above-named documents within the Time for Completion. We \nguarantee that the Works will then conform to the Schedule of Guarantees. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            575.697998046875,
            524.6279907226562,
            630.3819580078125
          ],
          "text": "Unless and until a formal Agreement is prepared and executed, this Letter of Tender, together \nwith your written acceptance thereof, shall constitute a binding contract between us. Our \nTender is binding upon us and subject to the modifications resulting from pre-award contract \nnegotiations. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            642.927978515625,
            507.94000244140625,
            656.2119750976562
          ],
          "text": "We understand that you are not bound to accept the lowest or any tender you may receive. \n"
        },
        {
          "bbox": [
            72.02400207519531,
            668.7279663085938,
            507.1000061035156,
            682.011962890625
          ],
          "text": "Signature _____________________________ \n in the capacity of ___________ \n"
        },
        {
          "bbox": [
            72.02400207519531,
            694.5279541015625,
            428.9800109863281,
            707.8119506835938
          ],
          "text": "Duly authorized to sign tenders for and on behalf of _________________ \n"
        },
        {
          "bbox": [
            72.02400207519531,
            720.3280029296875,
            507.1000061035156,
            733.6119995117188
          ],
          "text": "Address:  \n_______________________________________ \n \n"
        },
        {
          "bbox": [
            72.02400207519531,
            746.1239624023438,
            408.07000732421875,
            759.407958984375
          ],
          "text": "Date:  \n_______________________________________ \n"
        }
      ]
    }
  ],
  "native_locator_count": 0,
  "issues": [],
  "version": "preflight-v1"
}